Loading...
Search for: microfluidics
0.012 seconds
Total 321 records

    Chaos control in single mode approximation of T-AFM systems using nonlinear delayed feedback based on sliding mode control

    , Article 2007 Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference ; Volume 3 PART B , 2008 , Pages 725-730 ; ISBN: 9780791848043 Sadeghian, H ; Salarieh, H ; Arjmand, M. T ; Alasty, A ; Sharif University of Technology
    Abstract
    The taping mode Atomic Force Microscopic (T-AFM) can be properly described by a sinusoidal excitation of its base and nonlinear potential interaction with sample. Thus the cantilever may cause chaotic behavior which decreases the performance of the sample topography. In this paper a nonlinear delayed feedback control.is proposed to control.chaos in a single mode approximation of a T-AFM system. Assuming model parameters uncertainties, the first order Unstable Periodic Orbits (UPOs) of the system is stabilized using the sliding nonlinear delayed feedback control. The effectiveness of the presented methods is numerically verified and the results show the high performance of the control.er  

    Numerical modeling of surface reaction kinetics in electrokinetically actuated microfluidic devices

    , Article Analytica Chimica Acta ; Vol. 838, issue , August , 2014 , pp. 64-75 ; ISSN: 00032670 Sadeghi, A ; Amini, Y ; Saidi, M. H ; Chakraborty, S ; Sharif University of Technology
    Abstract
    We outline a comprehensive numerical procedure for modeling of species transport and surface reaction kinetics in electrokinetically actuated microfluidic devices of rectangular cross section. Our results confirm the findings of previous simplified approaches that a concentration wave is created for sufficiently long microreactors. An analytical solution, developed for the wave propagation speed, shows that, when normalizing with the fluid mean velocity, it becomes a function of three parameters comprising the channel aspect ratio, the relative adsorption capacity, and the kinetic equilibrium constant. Our studies also reveal that the reactor geometry idealized as a slit, instead of a... 

    Interaction of 3D dewetting nanodroplets on homogeneous and chemically heterogeneous substrates

    , Article Journal of Physics Condensed Matter ; Vol. 26, Issue. 22 , 2014 ; ISSN: 09538984 Asgari, M ; Moosavi, A ; Sharif University of Technology
    Abstract
    Long-time interaction of dewetting nanodroplets is investigated using a long-wave approximation method. Although three-dimensional (3D) droplets evolution dynamics exhibits qualitative behavior analogous to two-dimensional (2D) dynamics, there is an extensive quantitative difference between them. 3D dynamics is substantially faster than 2D dynamics. This can be related to the larger curvature and, as a consequence, the larger Laplace pressure difference between the droplets in 3D systems. The influence of various chemical heterogeneities on the behavior of droplets has also been studied. In the case of gradient surfaces, it is shown how the gradient direction could change the dynamics. For a... 

    High frequency oscillatory flow in micro channels

    , Article Colloids and Surfaces A: Physicochemical and Engineering Aspects ; Vol. 460 , 2014 , pp. 355-360 ; ISSN: 09277757 Karbaschi, M ; Javadi, A ; Bastani, D ; Miller, R ; Sharif University of Technology
    Abstract
    This paper deals with computational and experimental studies on the oscillatory flow at high frequencies up to 100. Hz performed with the Oscillating Drop and Bubble Analyzer (ODBA) setup based on the capillary pressure technique. The CFD results are validated considering pressure amplitude experimental data. The simulated results of phase shift between the generated oscillatory flow and the consequent pressure amplitudes show also good agreement with the experimental data. In absence of any compressibility and viscoelasticity effects and assumptions, a complex velocity field during oscillation is the main reason for the observation of a phase shift. The results of velocity profiles at the... 

    Microfluidic devices as invitro microenvironments for -stem cell culture

    , Article Proceedings of the IASTED International Conference on Biomedical Engineering, BioMed 2014 ; 2014 , pp. 83-88 Shamloo, A ; Abeddoust, M ; Mehboudi, N ; Sharif University of Technology
    Abstract
    Many potential therapies are currently being studied that may promote neural regeneration and guide regenerating axons to form correct connections following injury. It has been shown that adult neurons have some limited regenerative capabilities, and the lack of connection formation between neurons is not an intrinsic inability of these cells to form axons after being damaged, but rather the inhibitory microenvironment of the injured tissue prevents regeneration. In this study, the polarization and chemotaxis of neuronal stem cells (NSC) in response to quantified gradients of nerve growth factor (NGF) was examined. To accomplish this, a microfluidic device was designed and fabricated to... 

    Pressure effects on electroosmotic flow of power-law fluids in rectangular microchannels

    , Article Theoretical and Computational Fluid Dynamics ; Vol. 28, issue. 4 , 2014 , pp. 409-426 ; ISSN: 09354964 Vakili, M. A ; Sadeghi, A ; Saidi, M. H ; Sharif University of Technology
    Abstract
    In this paper, the fully developed electroosmotic flow of power-law fluids in rectangular microchannels in the presence of pressure gradient is analyzed. The electrical potential and momentum equations are numerically solved through a finite difference procedure for a non-uniform grid. A complete parametric study reveals that the pressure effects are more pronounced at higher values of the channel aspect ratio and smaller values of the flow behavior index. The Poiseuille number is found to be an increasing function of the channel aspect ratio for pressure assisted flow and a decreasing function of this parameter for pressure opposed flow. It is also observed that the Poiseuille number is... 

    Cell-cell interactions mediate cytoskeleton organization and collective endothelial cell chemotaxis

    , Article Cytoskeleton ; Vol. 71, issue. 9 , 2014 , p. 501-512 Shamloo, A ; Sharif University of Technology
    Abstract
    This study investigates the role of cell-cell and cell-ligand interactions in cytoskeleton organization of endothelial cells (ECs) and their directional migration within a microfluidic device. The migration of ECs in response to a biochemical factor was studied. Mathematical analysis of the cell migration pathways and cellular cytoskeleton revealed that directional migration, migration persistence length, migration speed, and cytoskeletal stress fiber alignment can be mediated by the level of cell contacts as well as the presence or absence of a biochemical polarizing factor. It was shown that in the presence of a biochemical polarizing factor, higher cell density and more frequent cell... 

    Thermal transport characteristics pertinent to electrokinetic flow of power-law fluids in rectangular microchannels

    , Article International Journal of Thermal Sciences ; Vol. 79, issue , 2014 , p. 76-89 Vakili, M. A ; Saidi, M. H ; Sadeghi, A ; Sharif University of Technology
    Abstract
    In the present study, the thermal characteristics of electroosmotic flow of power-law fluids in rectangular microchannels in the presence of pressure gradient are investigated. The governing equations for fully developed flow under H1 thermal boundary conditions are first made dimensionless and subsequently solved through a finite difference procedure for a non-uniform grid. The influence of the major parameters on thermal features of the flow such as the temperature distribution and Nusselt number is discussed by a complete parametric study. The results reveal that the channel aspect ratio and the non-Newtonian characteristic of the fluid can affect the thermal behavior of the flow. It is... 

    Mass transport analysis of non-Newtonian fluids under combined electroosmotically and pressure driven flow in rectangular microreactors

    , Article Colloids and Surfaces A: Physicochemical and Engineering Aspects ; Volume 508 , 2016 , Pages 345-359 ; 09277757 (ISSN) Yousefian, Z ; Saidi, M. H ; Sharif University of Technology
    Elsevier 
    Abstract
    Hydrodynamically fully developed flow of power-law fluids under combined action of electroosmotic and pressure gradient forces in rectangular microreactors is analyzed considering heterogeneous catalytic reactions. The Poisson-Boltzmann, Cauchy momentum, and concentration equations are considered in two dimensions and after being dimensionless are numerically solved applying a finite difference algorithm. Variation of axial concentration gradient, and axial and horizontal mass diffusions are taken into account as well. To accomplish a more general analysis, the velocity distribution is obtained by solving continuity and Cauchy momentum equations and is not considered as an average axial... 

    Numerical simulation of collision between two droplets in the T-shaped microchannel with lattice Boltzmann method

    , Article AIP Advances ; Volume 6, Issue 11 , 2016 ; 21583226 (ISSN) Merdasi, A ; Ebrahimi, S ; Moosavi, A ; Shafii, M. B ; Kowsary, F ; Sharif University of Technology
    American Institute of Physics Inc 
    Abstract
    In this study, the Lattice Boltzmann Method (LBM) is used to investigate the deformation of two droplets within microfluidic T-junctions (MFTD). In order to increase the accuracy the two immiscible fluids are modeled using the He-Chen-Zhang model. First, this model is applied to ensure that the surface tension effect existing between the droplets and the continuous fluid is properly implemented in the model. Then the collision and merging of the two droplets within the intersection of a T-shaped microchannel is investigated. For generating droplet formation the effects of relevant dimensionless parameters such as the Reynolds, the Weber numbers as well as a collision parameter affecting the... 

    Skin diseases modeling using combined tissue engineering and microfluidic technologies

    , Article Advanced Healthcare Materials ; Volume 5, Issue 19 , 2016 , Pages 2459-2480 ; 21922640 (ISSN) Mohammadi, M. H ; Heidary Araghi, B ; Beydaghi, V ; Geraili, A ; Moradi, F ; Jafari, P ; Janmaleki, M ; Valente, K. P ; Akbari, M ; Sanati Nezhad, A ; Sharif University of Technology
    Wiley-VCH Verlag 
    Abstract
    In recent years, both tissue engineering and microfluidics have significantly contributed in engineering of in vitro skin substitutes to test the penetration of chemicals or to replace damaged skins. Organ-on-chip platforms have been recently inspired by the integration of microfluidics and biomaterials in order to develop physiologically relevant disease models. However, the application of organ-on-chip on the development of skin disease models is still limited and needs to be further developed. The impact of tissue engineering, biomaterials and microfluidic platforms on the development of skin grafts and biomimetic in vitro skin models is reviewed. The integration of tissue engineering and... 

    Analyzing mixing quality in a curved centrifugal micromixer through numerical simulation

    , Article Chemical Engineering and Processing: Process Intensification ; 2017 ; 02552701 (ISSN) Shamloo, A ; Vatankhah, P ; Akbari, A ; Sharif University of Technology
    Elsevier B.V 
    Abstract
    The Lab On a CD (LOCD), also known as Centrifugal Microfluidics, has evolved into a sophisticated platform for performing biomedical assays due to its marvelous miniaturization and accurate simulation of biological reactions. Among the numerous applications of the LOCD is fluid mixing. In this paper a centrifugal, serpentine micromixer is simulated and reformed toward better mixing performance. The micromixer was chosen to be curved as a curved design was found to be thrice as functional and compact as a rectilinear design, mixing-wise. The two angular velocity and opening radius parameters were originally hypothesized to affect mixing performance. Effect of angular velocity was studied over... 

    Microfluidic-based multi-organ platforms for drug discovery

    , Article Micromachines ; Volume 7, Issue 9 , 2016 ; 2072666X (ISSN) Rezaei Kolahchi, A ; Khadem Mohtaram, N ; Pezeshgi Modarres, H ; Mohammadi, M. H ; Geraili, A ; Jafari, P ; Akbari, M ; Sanati Nezhad, A ; Sharif University of Technology
    MDPI AG 
    Abstract
    Development of predictive multi-organ models before implementing costly clinical trials is central for screening the toxicity, efficacy, and side effects of new therapeutic agents. Despite significant efforts that have been recently made to develop biomimetic in vitro tissue models, the clinical application of such platforms is still far from reality. Recent advances in physiologically-based pharmacokinetic and pharmacodynamic (PBPK-PD) modeling, micro- and nanotechnology, and in silico modeling have enabled single- and multi-organ platforms for investigation of new chemical agents and tissue-tissue interactions. This review provides an overview of the principles of designing... 

    Efficient batch-mode mixing and flow patterns in a microfluidic centrifugal platform: a numerical and experimental study

    , Article Microsystem Technologies ; 2016 , Pages 1-13 ; 09467076 (ISSN) Mortazavi, S. M. A ; Tirandazi, P ; Normandie, M ; Saidi, M. S ; Sharif University of Technology
    Springer Verlag 
    Abstract
    During recent years centrifugal-based microfluidic devices known as Lab-on-a-CD have attracted a lot of attentions. Applications of these CD-based platforms are ubiquitous in numerous biological analyses and chemical syntheses. Mixing of different species in microscale is one of the essential operations in biochemical applications where this seemingly simple task remains a major obstruction. Application of centrifugal force, however, may significantly improve the flow agitation and mixing, especially when it is combined with the Coriolis force which acts perpendicular to centrifugal force. In this study, mixing process in minichambers located on a rotating platform under a periodic... 

    Microfluidic manipulation of Core/Shell nanoparticles for oral delivery of chemotherapeutics: A new treatment approach for colorectal cancer

    , Article Advanced Materials ; Volume 28, Issue 21 , 2016 , Pages 4134-4141 ; 09359648 (ISSN) Hasani Sadrabadi, M. M ; Taranejoo, S ; Dashtimoghadam, E ; Bahlakeh, G ; Majedi, F.S ; Vandersarl, J. J ; Janmaleki, M ; Sharifi, F ; Bertsch, A ; Hourigan, K ; Tayebi, L ; Renaud, P ; Jacob, K. I ; Sharif University of Technology
    Wiley-VCH Verlag 
    Abstract
    A microfluidics approach to synthesize core-shell nanocarriers with high pH tunability is described. The sacrificial shell protects the core layer with the drugs and prevents their release in the severe pH conditions of the gastrointestinal tract, while allowing for drug release in the proximity of a tumor. The proposed nanoparticulate drug-delivery system is designed for the oral administration of cancer therapeutics  

    A comparative study of collagen matrix density effect on endothelial sprout formation using experimental and computational approaches

    , Article Annals of Biomedical Engineering ; Volume 44, Issue 4 , 2016 , Pages 929-941 ; 00906964 (ISSN) Shamloo, A ; Mohammadaliha, N ; Heilshorn, S. C ; Bauer, A. L ; Sharif University of Technology
    Abstract
    A thorough understanding of determining factors in angiogenesis is a necessary step to control the development of new blood vessels. Extracellular matrix density is known to have a significant influence on cellular behaviors and consequently can regulate vessel formation. The utilization of experimental platforms in combination with numerical models can be a powerful method to explore the mechanisms of new capillary sprout formation. In this study, using an integrative method, the interplay between the matrix density and angiogenesis was investigated. Owing the fact that the extracellular matrix density is a global parameter that can affect other parameters such as pore size, stiffness,... 

    Analysis of non-newtonian fluids in microchannels with different wall materials

    , Article ASME 2009 7th International Conference on Nanochannels, Microchannels, and Minichannels ; 2009 , Pages 697-703 ; 9780791843499 (ISBN) Darbandi, M ; Behshad Shafii, M ; Safari Mohsenabad, S ; Sharif University of Technology
    Abstract
    The behavior of non-Newtonian fluids is considered as an important subject in micro scale and microfluidic flow researches. Because of the complexity and cost in the numerical works and the experimental set-ups in some instances, the analytical approach can be taken into account as a robust alternative tool to solve the non-Newtonian microfluidic flows in some special cases benefiting from a few simplified assumptions. In this work, we analyze the flow of two non-Newtonian fluids including the power-law and grade-fluid models in microchannels. For the grade-fluid, the stress tensors are defined considering the Rivlin-Ericksen tensor definitions. To avoid the complexities in the entrance... 

    Polyamide/titania hollow nanofibers prepared by core–shell electrospinning as a microextractive phase in a fabricated sandwiched format microfluidic device

    , Article Journal of Chromatography A ; Volume 1528 , 2017 , Pages 1-9 ; 00219673 (ISSN) Rezvani, O ; Hashemi Hedeshi, M ; Bagheri, H ; Sharif University of Technology
    Abstract
    In this study, a low–cost microfluidic device from polymethyl methacrylate was fabricated by laser engraving technique. The device is consisted of a central chip unit with an aligned microchannel. Both sides of the engraved microchannel were sandwiched by two synthesized sheets from polyamide/titania (PA/TiO2) hollow nanofibers as extractive phases. The inlet and outlet of the device were connected to the polyether ether ketone tubes, while a peristaltic pump was used to deliver both sample and desorbing solvent through the microchannel. The recorded scanning electron microscopy images from the surface of the synthesized PA/TiO2 nanofibers, exhibit a good degree of homogeneity and porosity... 

    Numerical simulation of the behavior of toroidal and spheroidal multicellular aggregates in microfluidic devices with microwell and U-shaped barrier

    , Article Micromachines ; Volume 8, Issue 12 , 2017 ; 2072666X (ISSN) Barisam, M ; Saidi, M. S ; Kashaninejad, N ; Vadivelu, R ; Nguyen, N. T ; Sharif University of Technology
    Abstract
    A microfluidic system provides an excellent platform for cellular studies. Most importantly, a three-dimensional (3D) cell culture model reconstructs more accurately the in vivo microenvironment of tissue. Accordingly, microfluidic 3D cell culture devices could be ideal candidates for in vitro cell culture platforms. In this paper, two types of 3D cellular aggregates, i.e., toroid and spheroid, are numerically studied. The studies are carried out for microfluidic systems containing U-shaped barrier as well as microwell structure. For the first time, we obtain oxygen and glucose concentration distributions inside a toroid aggregate as well as the shear stress on its surface and compare its... 

    Pressure-driven liquid-liquid separation in Y-shaped microfluidic junctions

    , Article Chemical Engineering Journal ; Volume 328 , 2017 , Pages 1075-1086 ; 13858947 (ISSN) Foroozan Jahromi, P ; Karimi Sabet, J ; Amini, Y ; Fadaei, H ; Sharif University of Technology
    Abstract
    On-chip phase separation of multiphase microflows at the divergence point of Y-shaped microfluidic junctions is an effective way for integrating continuous microstructured devices. In this study, flow pattern maps of various solvent pairs based on the volumetric flow rates of both phases have been drawn experimentally and compared with numerical prediction to investigate the effective domain for which complete phase separation occurred. Furthermore, sufficient separation of aqueous and organic phases at the end of the microchannel was achieved by controlling the pressure difference at the liquid-liquid interface via loading back-pressure on the organic phase. A mathematical model based on...