Loading...
Search for: coatings
0.01 seconds
Total 689 records

    Bed mixing and leachate recycling strategies to overcome pressure drop buildup in the biofiltration of hydrogen sulfide

    , Article Bioresource Technology ; Volume 109 , 2012 , Pages 26-30 ; 09608524 (ISSN) Roshani, B ; Torkian, A ; Aslani, H ; Dehghanzadeh, R ; Sharif University of Technology
    2012
    Abstract
    The effects of leachate recycling and bed mixing on the removal rate of H 2S from waste gas stream were investigated. The experimental setup consisted of an epoxy-coated three-section biofilter with an ID of 8cm and effective bed height of 120cm. Bed material consisted of municipal solid waste compost and PVC bits with an overall porosity of 54% and dry bulk density of 0.456gcm -3. Leachate recycling had a positive effect of increasing elimination capacity (EC) up to 21gSm -3 bedh -1 at recycling rates of 75mld -1, but in the bed mixing period EC declined to 8g Sm -3bedh -1. Pressure drop had a range of zero to 18mm H 2Om -1 in the course of leachate recycling. Accumulation of sulfur reduced... 

    Solid phase extraction of trace amounts of Pb(II) in opium, heroin, lipstick, plants and water samples using modified magnetite nanoparticles prior to its atomic absorption determination

    , Article Journal of the Iranian Chemical Society ; Volume 9, Issue 2 , 2012 , Pages 171-180 ; 1735207X (ISSN) Karimi, M. A ; Hatefi Mehrjardi, A ; Mohammadi, S. Z ; Mohadesi, A ; Mazloum Ardakani, M ; Hormozi Nezhad, M. R ; Kabir, A. A ; Sharif University of Technology
    2012
    Abstract
    A new, simple, fast and reliable solid-phase extraction method has been developed for separation/preconcentration of trace amounts of Pb(II) using dithizone/sodium dodecyl sulfate-immobilized on alumina-coated magnetite nanoparticles, and its determination by flame atomic absorption spectrometry (FAAS) and graphite furnace atomic absorption spectrometry (GFAAS) after eluting with 4.0 mol L -1 HNO 3. Optimal experimental conditions including pH, sample volume, eluent concentration and volume, and co-existing ions have been studied and established. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation of Pb(II)... 

    Fluid-structure interaction analysis in microfluidic devices: A dimensionless finite element approach

    , Article International Journal for Numerical Methods in Fluids ; Volume 68, Issue 9 , 2012 , Pages 1073-1086 ; 02712091 (ISSN) Afrasiab, H ; Movahhedy, M. R ; Assempour, A ; Sharif University of Technology
    2012
    Abstract
    In this paper, the so-called small time-step instability in finite element simulation of the fluid part is considered in fluid-structure interaction (FSI) problems in which a high-frequency vibrating structure interacts with an incompressible fluid. Such a situation is common in many microfluid manipulating devices. A treatment has been proposed that uses the dimensionless set of FSI governing equations in order to scale up the problem time step to a proper level that precludes the potential small time-step instability. Two-dimensional and three-dimensional finite element simulations of a mechanical micropumping device are performed to verify the efficiency of the presented approach. Solid... 

    Tractive rolling contact mechanics of graded coatings

    , Article International Journal of Solids and Structures ; Volume 49, Issue 6 , March , 2012 , Pages 929-945 ; 00207683 (ISSN) Guler, M. A ; Adibnazari, S ; Alinia, Y ; Sharif University of Technology
    2012
    Abstract
    In this study, the tractive rolling contact problem between a rigid cylinder and a graded coating is investigated. The main objective of this study is to investigate the effect of the stiffness ratio, the coefficient of friction and the coating thickness on the surface contact tractions, the surface in-plane stress, the stick zone length and the creep ratio parameter that may have a bearing on the fatigue life of the component. Assuming that the shear modulus varies exponentially through the thickness of the coating, the governing integral equations associated with the rolling contact problem are constructed. Furthermore, it is supposed that the contact patch is controlled by a central stick... 

    Novel polyamide-based nanofibers prepared by electrospinning technique for headspace solid-phase microextraction of phenol and chlorophenols from environmental samples

    , Article Analytica Chimica Acta ; Volume 716 , 2012 , Pages 34-39 ; 00032670 (ISSN) Bagheri, H ; Aghakhani, A ; Baghernejad, M ; Akbarinejad, A ; Sharif University of Technology
    2012
    Abstract
    A novel solid phase microextraction (SPME) fiber was fabricated by electrospinning method in which a polymeric solution was converted to nanofibers using high voltages. A thin stainless steel wire was coated by the network of polymeric nanofibers. The polymeric nanofiber coating on the wire was mechanically stable due to the fine and continuous nanofibers formation around the wire with a three dimensional structure. Polyamide (nylon 6), due to its suitable characteristics was used to prepare the unbreakable SPME nanofiber. The scanning electron microscopy (SEM) images of this new coating showed a diameter range of 100-200nm for polyamide nanofibers with a homogeneous and porous surface... 

    Elucidation of the structural texture of electrodeposited Ni/SiC nanocomposite coatings

    , Article Journal of Physical Chemistry C ; Volume 116, Issue 6 , January , 2012 , Pages 4105-4118 ; 19327447 (ISSN) Sohrabi, A ; Dolati, A ; Ghorbani, M ; Barati, M. R ; Stroeve, P ; Sharif University of Technology
    2012
    Abstract
    Crystallographic texture is one of the most sensitive parameters for controlling the microstructure of electrodeposited layers. In this work, we study the crystallographic texture of electrodeposited nickel-silicon carbide coatings. The nickel coatings containing SiC nanoparticles and microparticles were electrodeposited from an additive-free sulfate bath containing nickel ions and SiC particles. The effect of current density on the codeposited Ni/SiC was studied. The coatings were analyzed with scanning electron microscopy and X-ray diffraction. Pole figure studies were done to characterize the evolved crystallographic texture. The X-ray scans followed by Rietveld analysis using the... 

    Physical properties of sputtered amorphous carbon coating

    , Article Journal of Alloys and Compounds ; Volume 513 , 2012 , Pages 135-138 ; 09258388 (ISSN) Yari, M ; Larijani, M. M ; Afshar, A ; Eshghabadi, M ; Shokouhy, A ; Sharif University of Technology
    Abstract
    In this study the effect of deposition temperature and thickness on the physical properties of carbon films deposited by magnetron sputtering PVD was investigated. The results of Raman spectra and grazing incidence XRD (GIXRD) patterns show that the graphitization increases by increasing the deposition temperature. There is a change in deposition mechanism at 400 °C from amorphous carbon deposition to nano-structured graphite deposition. Also by increasing substrate temperature the electrical resistance of carbon films reduces significantly up to 300 °C and then remains largely constant. High intrinsic compressive stress in low temperature deposited carbon films causes cracks and... 

    Pyrolytic carbon coating for cytocompatibility of titanium oxide nanoparticles: A promising candidate for medical applications

    , Article Nanotechnology ; Volume 23, Issue 4 , 2012 ; 09574484 (ISSN) Behzadi, S ; Imani, M ; Yousefi, M ; Galinetto, P ; Simchi, A ; Amiri, H ; Stroeve, P ; Mahmoudi, M ; Sharif University of Technology
    2012
    Abstract
    Nanoparticles for biomedical use must be cytocompatible with the biological environment that they are exposed to. Current research has focused on the surface functionalization of nanoparticles by using proteins, polymers, thiols and other organic compounds. Here we show that inorganic nanoparticles such as titanium oxide can be coated by pyrolytic carbon (PyC) and that the coating has cytocompatible properties. Pyrolization and condensation of methane formed a thin layer of pyrolytic carbon on the titanium oxide core. The formation of the PyC shell retards coalescence and sintering of the ceramic phase. Our MTT assay shows that the PyC-coated particles are cytocompatible at employed doses  

    Innovative semi-analytical methodology to predict automobile body temperature distribution in the curing ovens

    , Article Heat Transfer Engineering ; Volume 33, Issue 2 , Jun , 2012 , Pages 109-117 ; 01457632 (ISSN) Hanafizadeh, P ; Sajadi, B ; Saidi, M. H ; Sharif University of Technology
    2012
    Abstract
    In automobile painting industries, new automobile body products frequently should be tested in order to determine the actual thermal behavior of a paint curing process before starting mass production. During the hardening processes of dipped paint coating, applied in the electrophoretic enameling process, or top paint coating, applied in the final coating process, the automobile body must be warmed up according to the specific paint manufacturer curve. Consequently, prediction of car body temperature during the curing process may be vital in the design and performance analysis of the paint ovens. Numerical simulation of these processes may reduce expensive and time-consuming experimental... 

    The effects of pulse plating variables on morphology and corrosion behavior of Zn-Fe alloy coatings

    , Article Journal of Coatings Technology Research ; Volume 9, Issue 2 , 2012 , Pages 215-218 ; 15470091 (ISSN) Roshanghias, A ; Heydarzadeh Sohi, M ; Sharif University of Technology
    2012
    Abstract
    Considerable researches have been focused on zinc-iron (Zn-Fe) alloy coatings due to their superior characteristics among zinc alloy electrodeposits in recent years. The corrosion behavior of these coatings depends on the phase structure and morphology of the Zn-Fe deposits. In this work the effects of pulse plating variables such as current density, off-time, frequency and pulse modes on the morphology and phase structure of Zn-Fe deposits was studied by scanning electron microscopy (SEM), X-ray diffraction (XRD) and energy dispersive spectrometry (EDS) analysis. The corrosion behavior of these coatings was measured by means of polarization curves and Neutral salt spray tests. It was shown... 

    Photocatalytic activity of TiO 2-capped ZnO nanoparticles

    , Article Journal of Materials Science: Materials in Electronics ; Volume 23, Issue 2 , 2012 , Pages 361-369 ; 09574522 (ISSN) Lak, A ; Simchi, A ; Nemati, Z. A ; Sharif University of Technology
    Abstract
    Using a combined hydrothermal and sol-gel route, TiO 2 -capped ZnO nanoparticles with an average size of 60 nm were prepared. The titania shell was amorphous with a thickness of ∼10 nm. Formation of Zn 2TiO 4 phase at higher calcination temperature was noticed. Effects of Ti/Zn molar ratio and coating time on the thickness of TiO 2 shell and the photoactivity of the particles for decolorization of Methylene Blue (MB) under UV lamp irradiation (3 mW/cm 2) were investigated. The nanoparticles were characterized by X-ray diffraction, transmission electron microscopy, fourier-transform infrared spectrometry (FTIR), diffuse reflectance spectroscopy (DLS), and atomic absorption spectroscopy.... 

    A study of the electrophoretic deposition of bioactive glass-chitosan composite coating

    , Article Ceramics International ; Volume 38, Issue 1 , January , 2012 , Pages 471-476 ; 02728842 (ISSN) Mehdipour, M ; Afshar, A ; Sharif University of Technology
    2012
    Abstract
    Bioactive glass is coated on implant's surface to improve corrosion resistance and osseointegration, when placed in the body. Bioactive glass particles were synthesized through a sol-gel process and deposited along with chitosan to form a composite coating on a stainless steel substrate using electrophoretic deposition technique. Stable suspensions of chitosan-bioactive glass were prepared using bioactive glass particles (<1 μm) and 0.5 g/l chitosan solution. The influence of ethanol-water ratio on deposition yield was investigated. For all process conditions, best results were achieved with suspension of 30 vol% water in ethanol-water containing 2 g/l bioactive glass. FTIR studies showed... 

    Numerical simulation of thermal barrier coating system under thermo-mechanical loadings

    , Article Proceedings of the World Congress on Engineering 2011, WCE 2011, 6 July 2011 through 8 July 2011 ; Volume 3 , July , 2011 , Pages 1959-1964 ; 9789881925152 (ISBN) Moridi, A ; Azadi, M ; Farrahi, G. H ; Sharif University of Technology
    2011
    Abstract
    In the present paper, numerical simulation of thermal barrier coating system under thermo-mechanical loadings is performed, using the finite element method in ABAQUS software. The base material is Aluminum-silicon alloy, A356.0 which is widely used in automotive components such as diesel engine cylinder heads. Thermal barrier coatings (TBCs) are applied to combustion chamber in order to reduce fuel consumption and pollutions and also improve fatigue life of components. The roughness effect of coating layers on stress distribution of test specimens is investigated. Semi-ellipsoid roughness of the interfaces between substrate/bond coat and bond coat/top coat are simulated to get the stress... 

    Novel unbreakable solid-phase microextraction fiber by electrodeposition of silica sol-gel on gold

    , Article Journal of Separation Science ; Volume 34, Issue 22 , 2011 , Pages 3246-3252 ; 16159306 (ISSN) Bagheri, H ; Sistani, H ; Ayazi, Z ; Sharif University of Technology
    Abstract
    A new technique for preparation of an unbreakable solid-phase microextraction (SPME) fiber, using sol-gel technology is developed. Primarily, an ultrathin two-dimensional intermediate film was prepared by hydrolysis of 3-(trimethoxysilyl)-1-propanthiol self-assembled monolayer grafted onto gold, then a stationary phase by electrodeposition of 3-(trimethoxysilyl) propylmethacrylate as a precursor, tetramethyl orthosilicate and polyethylene glycol as a coating polymer was produced. The scanning electron microscopy images revealed that the new fiber exhibits a rather porous and homogenous surface. The thermal stability of the fabricated fiber was investigated by thermogravimetric analysis. The... 

    A polypyrrole-based sorptive microextraction coating for preconcentration of malathion from aquatic media

    , Article Chromatographia ; Volume 74, Issue 9-10 , 2011 , Pages 731-735 ; 00095893 (ISSN) Bagheri, H ; Aghakhani, A ; Ayazi, Z ; Khakinezhad, M ; Sharif University of Technology
    Abstract
    A new micro-solid phase extraction method was developed by combining solid-phase extraction and stir bar sorptive extraction to benefit from the advantages of both techniques. A polypyrrole coating was electrochemically synthesized on the surface of an already used graphite furnace, employed in electro-thermal atomic absorption spectroscopy. The cylindrical geometry of the graphite tube provided a rather huge surface area, suitable for sorptive extraction. The novel sorbent coating was examined as an extracting medium to isolate malathion. Effects of different parameters such as extraction time, salt concentration, sample volume, desorption solvent and time were investigated and optimized.... 

    Electrodeposition of Ni/WC nano composite in sulfate solution

    , Article Materials Chemistry and Physics ; Volume 129, Issue 3 , 2011 , Pages 746-750 ; 02540584 (ISSN) Mohajeri, S ; Dolati, A ; Rezagholibeiki, S ; Sharif University of Technology
    Abstract
    Metal matrix composite coatings have gained great attention due to their exclusive properties. They have shown the properties of a metallic host material modified by addition of a second phase. In electrodeposition of Ni/WC nano composite, nickel was deposited on the substrates by DC electrodeposition in Watt's based bath containing nickel sulfate, nickel chloride, boric acid and sodium dodecyl sulfate. WC content in the coating was determined by different parameters such as current density, powder content and surfactant amount. Mechanism of electrodeposition was analyzed by cyclic voltammetry and was confirmed by Guglielmi model. Surface morphology was studied by scanning electron... 

    Electrodeposition and characterization of Ni-Co/SiC nanocomposite coatings

    , Article Journal of Alloys and Compounds ; Volume 509, Issue 39 , 2011 , Pages 9406-9412 ; 09258388 (ISSN) Bahadormanesh, B ; Dolati, A ; Ahmadi, M. R ; Sharif University of Technology
    2011
    Abstract
    Ni-Co/SiC nanocomposite coatings were electrodeposited in a modified watt type of Ni-Co bath containing 20 nm SiC particles to be codeposited. Potentiodynamic polarization tests were conducted to study the effect of the SiC particulates on the electrodeposition of Ni and Co. Scanning electron microscopy was used to assess the morphology of the Ni-Co alloy and Ni-Co/SiC nanocomposite coatings. The distribution of the particulates in the matrix was considered by means of transmission electron microscopy. Applying nanomechanical testing instruments coupled to atomic force microscopy, mechanical properties of the alloy and composite coatings were studied and compared. The presence of 11 vol.%... 

    Electrophoretic deposition of chitosan/45S5 Bioglass® composite coatings for orthopaedic applications

    , Article Surface and Coatings Technology ; Volume 205, Issue 23-24 , 2011 , Pages 5260-5268 ; 02578972 (ISSN) Pishbin, F ; Simchi, A ; Ryan, M. P ; Boccaccini, A. R ; Sharif University of Technology
    2011
    Abstract
    This article presents experimental results on the electrophoretic deposition (EPD) of bioresorbable chitosan/45S5 Bioglass® composite coatings for orthopaedic implants based on the Taguchi design of experiments (DOE) approach. The influence of EPD parameters including Bioglass® concentration, electric voltage and deposition time on deposition yield was studied by an orthogonal Taguchi array of L18 type. Multivariate analysis of variance (MANOVA) and regression analysis based on the partial least-square method were used to identify the significant factors affecting the deposition yield and its stability during constant-voltage EPD. The coatings were characterised by high resolution scanning... 

    Coating thickness and roughness effect on stress distribution of A356.0 under thermo-mechanical loadings

    , Article Procedia Engineering, 5 June 2011 through 9 June 2011 ; Volume 10 , June , 2011 , Pages 1372-1377 ; 18777058 (ISSN) Moridi, A ; Azadi, M ; Farrahi, G. H ; Sharif University of Technology
    2011
    Abstract
    Cast aluminium-silicon alloy, A356.0, is widely used in automotive components such as diesel engine cylinder heads and also in aerospace industries because of its outstanding mechanical, physical, and casting properties. Thermal barrier coatings are applied to combustion chamber in order to reduce fuel consumption and pollutions and also improve fatigue life of components. However, studies on behaviour of A356.0 with thermal barrier coating are still rare. The purpose of the present work is to simulate stress distribution of A356.0 under thermo-mechanical cyclic loadings, using a two-layer elastic-visco-plastic model of ABAQUS software. The results of stress-strain hysteresis loop are... 

    Overall electroelastic moduli of particulate piezocomposites with non-dilute BCC microstructure

    , Article International Journal of Mechanical Sciences ; Volume 53, Issue 9 , 2011 , Pages 777-785 ; 00207403 (ISSN) Hashemi, R ; Kargarnovin, M. H ; Sharif University of Technology
    Abstract
    The present paper addresses an analytical method to determine the overall behavior of piezocomposite materials containing body centered cubic (BCC) distribution of arbitrary oriented ellipsoidal heterogeneities. This approach is based on the extension of the electromechanical equivalent inclusion method (EMEIM) to interacting multi-inhomogeneities. In this treatment the short and long range interactions of the piezoelectric particles are appropriately incorporated through the homogenizing eigenstrainelectric field. The periodicity of the microstructure of the medium suggests representing the eigenfields in terms of Fourier series, accounting for the matrixparticle, interparticle and...