Loading...
Search for: gait-analysis
0.01 seconds
Total 38 records

    The gait and energy efficiency of stance control knee-ankle-foot orthoses: A literature review

    , Article Prosthetics and Orthotics International ; Volume 40, Issue 2 , 2016 , Pages 202-214 ; 03093646 (ISSN) Rafiaei, M ; Bahramizadeh, M ; Arazpour, M ; Samadian, M ; Hutchins, S. W ; Farahmand, F ; Mardani, M. A ; Sharif University of Technology
    SAGE Publications Inc  2016
    Abstract
    Background: The use of knee-ankle-foot orthoses with drop locked knee joints produces some limitations for walking in subjects with quadriceps muscle weakness. The development of stance control orthoses can potentially improve their functionality. Objectives: The aim of this review was to compare the evidence of the effect of stance control orthoses to knee-ankle-foot orthoses with drop locked knee joints in improving kinematic variables and energy efficiency of walking by subjects with quadriceps muscle weakness caused by different pathologies. Study design: Literature review. Methods: Based on selected keywords and their composition, a search was performed in Google Scholar, PubMed,... 

    A study on validating KinectV2 in comparison of Vicon system as a motion capture system for using in Health Engineering in industry

    , Article Nonlinear Engineering ; Volume 6, Issue 2 , 2017 , Pages 95-99 ; 21928010 (ISSN) Jebeli, M ; Bilesan, A ; Arshi, A ; Sharif University of Technology
    Walter de Gruyter GmbH  2017
    Abstract
    The currently available commercial motion capture systems are constrained by space requirement and thus pose difficulties when used in developing kinematic description of human movements within the existing manufacturing and production cells. The Kinect sensor does not share similar limitations but it is not as accurate. The proposition made in this article is to adopt the Kinect sensor in to facilitate implementation of Health Engineering concepts to industrial environments. This article is an evaluation of the Kinect sensor accuracy when providing three dimensional kinematic data. The sensor is thus utilized to assist in modeling and simulation of worker performance within an industrial... 

    Quantitative evaluation of parameters affecting the accuracy of Microsoft Kinect in GAIT analysis

    , Article 2016 23rd Iranian Conference on Biomedical Engineering and 2016 1st International Iranian Conference on Biomedical Engineering, ICBME 2016, 23 November 2016 through 25 November 2016 ; 2017 , Pages 306-311 ; 9781509034529 (ISBN) Jamali, Z ; Behzadipour, S ; Sharif University of Technology
    Abstract
    To date various commercial systems have been used in the GAIT analysis. These systems have some difficulties for clinical use, such as interfering with normal movement and high prices. The possibility of utilization of Kinect as a sensor for GAIT analysis has been studied in this research. The accuracy of Kinect in calculation of GAIT parameters such as lower limb joint angles, stride time, and stride length were computed during normal walking. The effects of the sensor's position and direction relative to the walkway were also investigated. The Kinect sensor was installed at different positions toward the motion path. In each position the data was recorded by both Kinect and a commercial... 

    Coordinated activities of trunk and upper extremity muscles during walker-assisted paraplegic gait: A synergy study

    , Article Human Movement Science ; Volume 62 , 2018 , Pages 184-193 ; 01679457 (ISSN) Baniasad, M ; Farahmand, F ; Arazpour, M ; Zohoor, H ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    Individuals with spinal cord injury (SCI) at lower thoracic levels might walk independently with the aid of mechanical orthoses and walker by using their unimpaired trunk and upper extremity muscles (TUEM). The required motor skills and the associated subtasks of the paraplegic locomotion, however, have not been well understood yet. The purpose of this study was to investigate the coordination of the TUEM activities throughout the paraplegic gait cycle using synergy analysis. For eight paraplegic individuals (30.6 ± 11.6 years; SCI level: T12), the kinematics data and the surface electromyography (EMG) signals of TUEM were recorded during 15 gait cycles. Non-negative matrix factorization... 

    P 043 – Center of pressure progression and ground reaction forces are altered in cerebral palsy crouch gait

    , Article Gait and Posture ; Volume 65 , 2018 , Pages 307-308 ; 09666362 (ISSN) Salehi, A ; Khandan, A ; Arab Baniasad, M ; Baghdadi, S ; Farahmand, F ; Zohoor, H ; Sharif University of Technology
    Elsevier B.V  2018

    P 134 – Absence of the patella has minimal effects on sagittal plane gait parameters

    , Article Gait and Posture ; Volume 65 , 2018 , Pages 462-464 ; 09666362 (ISSN) Baghdadi, S ; Khandan, A ; Arab Baniasad, M ; Darbandi, H ; Vafaei, A. R ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    Patella is the latest addition to the animal's skeleton. It's role in normal walking has not been clearly defined. A 9-year-old girl with congenital absence of the patella was assessed using instrumented gait analysis. The results show a tendency for the limb for external rotation, which is more pronounced during swing. We suggest that the role of the patella is mainly to redirect the force of the quadriceps tendon medially. The classically described role, which is to increase the lever arm of the quadriceps tendon, was not confirmed in this study. © 2018 Elsevier B.V  

    O 027 - There are common patterns of muscle synergy in cerebral palsy crouch gait

    , Article Gait and Posture ; Volume 65 , 2018 , Pages 55-56 ; 09666362 (ISSN) Shojaeefard, M ; Khandan, A ; Baniasad, M. A ; Farahmand, F ; Baghdadi, S ; Vafaei, A ; Narimani, R ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    Background: Muscle synergy is the leading hypothesis on how the central nervous system coordinates limb functions. Cerebral palsy (CP) patients utilize fewer synergies, and are believed to have a simpler neuromuscular control. This study was undertaken to determine whether consistent muscle synergies are recruited during ambulation in cerebral palsy crouch gait and how the muscles contribute to such synergies. Methods: Ten ambulatory CP patients were recruited. All walked with crouch gait. sEMG data were collected from 14 lower limb muscles during gait analysis. Non-negative matrix factorization method was utilized to extract muscle synergies. Results and significance: A total of five... 

    Designing instrumented walker to measure upper-extremity’s efforts: a case study

    , Article Assistive Technology ; 2018 , Pages 1-9 ; 10400435 (ISSN) Khodadadi, M ; Arab Baniasad, M ; Arazpour, M ; Farahmand, F ; Zohoor, H ; Sharif University of Technology
    Taylor and Francis Inc  2018
    Abstract
    The high prevalence of shoulder pain in using walkers in patients who have spinal cord injury (SCI). Also, the limited options available to economically measure grip forces in walkers, which drove the need to create one. This article describes a method to obtain upper-extremities’ forces and moments in a person with SCI by designing an appropriate instrumented walker. First, since the commercial multidirectional loadcells are too expensive, custom loadcells are fabricated. Ultimately, a complete gait analysis by means of VICON motion analysis and using inverse dynamic method has been held to measure upper-extremities’ efforts. The results for a person with SCI using a two-wheel walker in low... 

    Role and significance of trunk and upper extremity muscles in walker-assisted paraplegic gait: a case study

    , Article Topics in Spinal Cord Injury Rehabilitation ; Volume 24, Issue 1 , 2018 , Pages 18-27 ; 10820744 (ISSN) Baniasad, M ; Farahmand, F ; Arazpour, M ; Zohoor, H ; Sharif University of Technology
    Thomas Land Publishers Inc  2018
    Abstract
    Background and Purpose: Understanding the role and significance of trunk and upper extremity muscles in paraplegic gait can help in designing more effective assistive devices for these patients and also provides valuable information for improving muscle strengthening programs. Methods: In a patient with a spinal cord injury (SCI) who could walk independently (rating scale of ambulatory capacity, 9) with the aid of bilateral ankle-foot orthosis and a walker, the kinematics, kinetics and electromyographic (EMG) activities of 16 muscles from the trunk and upper and lower extremities were recorded during gait. The onset, cessation, and duration of the EMG signal were associated with the 4 phases... 

    Designing instrumented walker to measure upper-extremity’s efforts: A case study

    , Article Assistive Technology ; Volume 31, Issue 5 , 2019 , Pages 267-275 ; 10400435 (ISSN) Khodadadi, M ; Baniasad, M. A ; Arazpour, M ; Farahmand, F ; Zohoor, H ; Sharif University of Technology
    Taylor and Francis Inc  2019
    Abstract
    The high prevalence of shoulder pain in using walkers in patients who have spinal cord injury (SCI). Also, the limited options available to economically measure grip forces in walkers, which drove the need to create one. This article describes a method to obtain upper-extremities’ forces and moments in a person with SCI by designing an appropriate instrumented walker. First, since the commercial multidirectional loadcells are too expensive, custom loadcells are fabricated. Ultimately, a complete gait analysis by means of VICON motion analysis and using inverse dynamic method has been held to measure upper-extremities’ efforts. The results for a person with SCI using a two-wheel walker in low... 

    Employing a novel gait pattern generator on a social humanoid robot

    , Article Scientia Iranica ; Volume 26, Issue 4A , 2019 , Pages 2154-2166 ; 10263098 (ISSN) Meghdari, A ; Behzadipour, S ; Abedi, M ; Sharif University of Technology
    Sharif University of Technology  2019
    Abstract
    This paper presents a novel Gait Pattern Generator ((IPC) developed for the "Alice" social humanoid robot, which up to now lacked an appropriate walking pattern. Due to t he limitations of this robot, the proposed gate pattern generator was formulated based on a nine-mass model to decrease the modeling errors and t he inverse kinematics of the whole lower-body was solved in such a way that the robot remained statically stable during t he movements. The main challenge of this work was to solve t he inverse kinematics of a 7-link chain with 12 degrees of freedom. For this purpose, a new graphical-numerical technique has been provided using the definition of the kinematic equations of the robot... 

    Employing a novel gait pattern generator on a social humanoid robot

    , Article Scientia Iranica ; Volume 26, Issue 4A , 2019 , Pages 2154-2166 ; 10263098 (ISSN) Meghdari, A ; Behzadipour, S ; Abedi, M ; Sharif University of Technology
    Sharif University of Technology  2019
    Abstract
    This paper presents a novel Gait Pattern Generator ((IPC) developed for the "Alice" social humanoid robot, which up to now lacked an appropriate walking pattern. Due to t he limitations of this robot, the proposed gate pattern generator was formulated based on a nine-mass model to decrease the modeling errors and t he inverse kinematics of the whole lower-body was solved in such a way that the robot remained statically stable during t he movements. The main challenge of this work was to solve t he inverse kinematics of a 7-link chain with 12 degrees of freedom. For this purpose, a new graphical-numerical technique has been provided using the definition of the kinematic equations of the robot... 

    vThe effect of saddle-assistive device on improving the gait parameters of patients with the lower limbs weakness: a pilot study

    , Article Journal of Bionic Engineering ; Volume 17, Issue 6 , 2020 , Pages 1175-1185 Hojjati Najafabadi, A ; Amini, S ; Farahmand, F ; Sharif University of Technology
    Springer  2020
    Abstract
    To help walking, using assistive devices can be considered to reduce the loads caused by weight and to effectively decrease the propulsive forces. In this study, a mobility Saddle-Assistive Device (S-AD) supporting body weight while walking was evaluated on two healthy volunteers. This device is based on the support of body weight against gravity with the help of a saddle, which is not used in other passive mobility assistive devices. To prove the efficiency of this device, the experimental results obtained while walking with this device were compared with those related to walking without the assistive device. The results showed that this device could significantly reduce the forces and... 

    A novel method of gait synthesis for bipedal fast locomotion

    , Article Journal of Intelligent and Robotic Systems: Theory and Applications ; Volume 53, Issue 2 , 2008 , Pages 101-118 ; 09210296 (ISSN) Meghdari, A ; Sohrabpour, S ; Naderi, D ; Tamaddoni, S. H ; Jafari, F ; Salarieh, H ; Sharif University of Technology
    2008
    Abstract
    Common methods of gait generation of bipedal locomotion based on experimental results, can successfully synthesize biped joints' profiles for a simple walking. However, most of these methods lack sufficient physical backgrounds which can cause major problems for bipeds when performing fast locomotion such as running and jumping. In order to develop a more accurate gait generation method, a thorough study of human running and jumping seems to be necessary. Most biomechanics researchers observed that human dynamics, during fast locomotion, can be modeled by a simple spring loaded inverted pendulum system. Considering this observation, a simple approach for bipedal gait generation in fast... 

    Design of a marker-based human motion tracking system

    , Article Biomedical Signal Processing and Control ; Volume 2, Issue 1 , 2007 , Pages 59-67 ; 17468094 (ISSN) Kolahi, A ; Hoviattalab, M ; Rezaeian, T ; Alizadeh, M ; Bostan, M ; Mokhtarzadeh, H ; Sharif University of Technology
    2007
    Abstract
    In this paper a complete design of a high speed optical motion analyzer system has been described. The main core of the image processing unit has been implemented by the differential algorithm procedure. Some intelligent and conservative procedures that facilitate the search algorithm have also been proposed and implemented for the processing of human motions. Moreover, an optimized modified direct linear transformation (MDLT) method has been used to reconstruct 3D markers positions which are used for deriving kinematic characteristics of the motion. Consequently, a set of complete tests using some simple mechanical devices were conducted to verify the system outputs. Considering the system... 

    Kinematic and dynamic analysis of the gait cycle of above-knee amputees

    , Article Scientia Iranica ; Volume 13, Issue 3 , 2006 , Pages 261-271 ; 10263098 (ISSN) Farahmand, F ; Rezaeian, T ; Narimani, R ; Hejazi Dinan, P ; Sharif University of Technology
    Sharif University of Technology  2006
    Abstract
    The change of gait pattern and muscular activity following amputation is thought to be responsible for the higher incidence of joint degenerative disorders observed in amputees. Considering the lack of consistent data in the literature, the purpose of the present study was to measure and analyze the spatio-temporal variables, the kinematics and, particularly, the net joint moments of the intact and prosthetic limbs of above knee amputee subjects during walking and to compare the results with those of normals. The gait characteristics of five transfemoral amputees and five normal subjects were measured using videography and a force platform. The human body was modeled as a 2-D sagittal plane... 

    Effects of medial thrust gait on lower extremity kinetics in patients with knee osteoarthritis

    , Article Ortopedia, traumatologia, rehabilitacja ; Volume 23, Issue 2 , 2021 , Pages 115-120 ; 20844336 (ISSN) Bokaeian, H. R ; Esfandiarpour, F ; Zahednejad, S ; Kouhzad Mohammadi, H ; Farahmand, F ; Sharif University of Technology
    NLM (Medline)  2021
    Abstract
    BACKGROUND: Medial thrust (MT) gait is a nonsurgical approach for reducing the knee adduction moment (KAM) in patients with knee osteoarthritis. However, its usefulness is indeterminate due to scarcity of research about changes in lower extremity kinetics and the ground reaction force (GRF) which have been investigated in this study. MATERIALS AND METHODS: Twenty patients (6 males, 14 females, age: 56.2±6.2 years) with medial knee osteo-arthritis participated in this cross-sectional study. A 12-camera motion analysis system and two force plates recorded kinematic and GRF data while participants walked barefoot along a 12m path with 1) their regular gait pattern and 2) MT gait pattern. The... 

    Quantitative changes in gait parameters after cycling among multiple sclerosis patients with ataxia:a pilot study

    , Article Journal of Modern Rehabilitation ; Volume 16, Issue 4 , 2022 , Pages 355-363 ; 2538385X (ISSN) Rahimibarghani, S ; Emami Razavi, S. Z ; Naser Moghadasi, A ; Azadvari, M ; Shojaee Fard, M ; Rahimi Dehgolan, S ; Sharif University of Technology
    Tehran University of Medical Sciences  2022
    Abstract
    Introduction: Cerebellar ataxia is a common symptom of multiple sclerosis (MS), particularly in progressive forms, where gait and balance problems are the most debilitating symptoms. Exercise training is a critical component of rehabilitation in managing equilibrium dysfunction, and stationary bicycling is a safe, feasible, and effective method to reduce the symptom. Clinical walking performance tests are typically used to assess gait in these patients. However, gait analysis technologies are more sensitive and accurate at detecting subtle and subclinical changes. The purpose of this study was to determine the changes in gait parameters in MS patients with ataxic gait after using a...