Loading...
Search for: magnetic-fluids
0.005 seconds
Total 30 records

    Convective-heat transfer of magnetic-sensitive nanofluids in the presence of rotating magnetic field

    , Article Applied Thermal Engineering ; Volume 116 , 2017 , Pages 329-343 ; 13594311 (ISSN) Fadaei, F ; Molaei Dehkordi, A ; Shahrokhi, M ; Abbasi, Z ; Sharif University of Technology
    Elsevier Ltd  2017
    Abstract
    In this work, forced-convection heat transfer of magnetic-sensitive nanofluids has been investigated in the presence of rotating magnetic field. In this regard, the laminar, Newtonian, incompressible, and two-dimensional (2D) fluid flow in a horizontal duct subject to constant wall temperature boundary condition was modeled. Moreover, the fluid was supposed to be non-electrical conductive and the magnetic field source comprised of two time varying components perpendicular to each other. Influences of magnetic field intensity and frequency, inlet fluid velocity, and spin viscosity on the forced-convection heat transfer of the magnetic nanofluids were investigated. It was found that the... 

    Visualization of pool boiling heat transfer of magnetic nanofluid

    , Article Heat Transfer - Asian Research ; Volume 48, Issue 7 , 2019 , Pages 2700-2713 ; 10992871 (ISSN) Zarei Saleh Abad, M ; Ebrahimi Dehshali, M ; Bijarchi, M. A ; Shafii, M. B ; Moosavi, A ; Sharif University of Technology
    John Wiley and Sons Inc  2019
    Abstract
    To increase heat transfer, ferrofluids have been utilized to study the effective parameters of pool boiling. Changes and possible enhancement of pool boiling heat transfer of magnetic fluids is a function of magnetic field and concentration of nanoparticles. To the best knowledge of the authors, no systematic experiments have been conducted to visualize the phenomena during the boiling of ferrofluids with different concentrations. In this study an experimental investigation has been conducted, by designing and fabricating a novel hele-shaw vessel with glass sides, to explore via visualizations some details in the pool boiling of ferrofluids. Boiling patterns of ferrofluids at various... 

    Ferrofluid flow and heat transfer from a sphere in the presence of nonuniform magnetic fields

    , Article Journal of Heat Transfer ; Volume 141, Issue 11 , 2019 ; 00221481 (ISSN) Abbasi, Z ; Molaei Dehkordi, A ; Sharif University of Technology
    American Society of Mechanical Engineers (ASME)  2019
    Abstract
    In this article, the effects of nonuniform magnetic fields on the hydrodynamics and heat transfer from a heated sphere to its surrounding ferrofluid flow have been investigated. Kelvin body forces originate from the nonuniformity of the applied magnetic field and can generate the vortices behind the sphere leading to a considerable change in the velocity and temperature fields. The applied magnetic field disturbs the thermal boundary layer and decreases heat-transfer resistance, leading to a significant enhancement in the heat-transfer coefficient. Variations of the local and average Nusselt number value (Nu), separation angle, recirculation length, and drag coefficient were considered to... 

    Forced-convection heat transfer of ferrofluids in a circular duct partially filled with porous medium in the presence of magnetic field

    , Article Journal of Magnetism and Magnetic Materials ; Volume 475 , 2019 , Pages 304-315 ; 03048853 (ISSN) Fadaei, F ; Shahrokhi, M ; Molaei Dehkordi, A ; Abbasi, Z ; Sharif University of Technology
    Elsevier B.V  2019
    Abstract
    In this article, effects of magnetic fields induced by a finite length solenoid on the forced-convection heat transfer in a pipe partially filled with porous medium have been investigated. In this regard, two-dimensional steady-state fluid flow in the pipe was considered and the Darcy–Brinkman equation of motion was applied to model the fluid flow in the porous medium, as well as the thermal equilibrium was assumed between the solid phase and the magnetic nanofluid. Effects of electric current passing through the solenoid and the solenoid dimensions (i.e.; diameter and length) on the forced-convection heat transfer were studied carefully. The combined effects of the magnetic field and the... 

    The effect of a non-uniform pulse-width modulated magnetic field with different angles on the swinging ferrofluid droplet formation

    , Article Journal of Industrial and Engineering Chemistry ; Volume 84 , 2020 , Pages 106-119 Bijarchi, M. A ; Favakeh, A ; Shafii, M. B ; Sharif University of Technology
    Korean Society of Industrial Engineering Chemistry  2020
    Abstract
    In this study, ferrofluid droplet formation from a nozzle in the presence of a non-uniform Pulse-Width Modulated (PWM) magnetic field with different angles was studied experimentally. A Drop-on-Demand platform was introduced and three different regimes of droplet formation were observed. The regime map of the droplet formation was presented. A new type of droplet formation evolution was observed in which the droplet is formed while it is swinging around the nozzle, and the satellite droplet is not generated in this regime. The effects of five important parameters including magnetic flux density, applied magnetic frequency, duty cycle, distance between the nozzle and the center of the upper... 

    Ferrofluid droplet manipulation using an adjustable alternating magnetic field

    , Article Sensors and Actuators, A: Physical ; Volume 301 , 2020 Bijarchi, M. A ; Favakeh, A ; Sedighi, E ; Shafii, M. B ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Magnetically actuated droplet manipulation offers a promising tool for biomedical and engineering applications, such as drug delivery, biochemistry, sample handling in lab-on-chip devices and tissue engineering. In this study, characteristics of an adjustable alternating magnetic field generated by a magnetic coil for droplet manipulation was investigated which enables more control on droplet transport, and it can be considered as a suitable alternative for moving magnets or an array of micro-coils. By adjusting the magnetic flux density, the duty cycle and applied magnetic frequency, the manipulation of water-based ferrofluid droplets with a bio-compatible surfactant for different volumes... 

    Numerical investigation on mixing intensification of ferrofluid and deionized water inside a microchannel using magnetic actuation generated by embedded microcoils for lab-on-chip systems

    , Article Chemical Engineering and Processing - Process Intensification ; Volume 147 , 2020 Saadat, M ; Shafii, M. B ; Ghassemi, M ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Effective and rapid mixing is crucial for chemical and biological processes. The purpose of the current study is to investigate the effect of steady and varying magnetic field on the mixing of a water-based ferrofluid and two streams of deionized water inside a microchannel for Lab-on-Chip applications. To this end, the nonlinear governing equations, the momentum equation, the continuity equation, the mass transport equation and the Maxwell-Ampere equations are numerically solved. A commercial code based on the finite-element method is used and the numerical simulations are validated by the experimental results in the literature. To augment the mixing performance, the effects of influencing... 

    Investigation of a Novel Microfluidic Device for Label-Free Ferrohydrodynamic Cell Separation on a Rotating Disk

    , Article IEEE Transactions on Biomedical Engineering ; Volume 67, Issue 2 , 2020 , Pages 372-378 Shamloo, A ; Besanjideh, M ; Sharif University of Technology
    IEEE Computer Society  2020
    Abstract
    Negative magnetophoresis is a novel and attractive method for continuous microparticle sorting inside a magnetic medium. In this method, diamagnetic particles are sorted based on their sizes using magnetic buoyancy force and without any labeling process. Although this method provides some attractive features, such as low-cost fabrication and ease of operation, there are some obstacles that adversely affect its performance, especially for biological applications. Most types of magnetic media, such as ferrofluids, are not biocompatible, and the time-consuming process of sample preparation can be threatening to the viability of the cells within the sample. Furthermore, in this method, both the... 

    Heat transfer enhancement of Fe3O4 ferrofluids in the presence of magnetic field

    , Article Journal of Magnetism and Magnetic Materials ; Volume 429 , 2017 , Pages 314-323 ; 03048853 (ISSN) Fadaei, F ; Shahrokhi, M ; Molaei Dehkordi, A ; Abbasi, Z ; Sharif University of Technology
    Elsevier B.V  2017
    Abstract
    In this article, three-dimensional (3D) forced-convection heat transfer of magnetic nanofluids in a pipe subject to constant wall heat flux in the presence of single or double permanent magnet(s) or current-carrying wire has been investigated and compared. In this regard, laminar fluid flow and equilibrium magnetization for the ferrofluid were considered. In addition, variations of magnetic field in different media were taken into account and the assumption of having a linear relationship of magnetization with applied magnetic field intensity was also relaxed. Effects of magnetic field intensity, nanoparticle volume fraction, Reynolds number value, and the type of magnetic field source... 

    Multiphysics flow modeling and in vitro toxicity of iron oxide nanoparticles coated with poly(vinyl alcohol)

    , Article Journal of Physical Chemistry C ; Volume 113, Issue 6 , 2009 , Pages 2322-2331 ; 19327447 (ISSN) Mahmoudi, M ; Shokrgozar, M. A ; Simchi, A ; Imani, M ; Milani, A. S ; Stroeve, P ; Vali, H ; Häfeli, U. O ; Bonakdar, S ; Sharif University of Technology
    2009
    Abstract
    This study investigated the behavior of ferrofluids containing superparamagnetic iron oxide nanoparticles (SPION) of various compositions for potential applications in drug delivery and imaging. To ensure biocompatibility, the interaction of these SPION with two cell lines (adhesive and suspended) was also investigated using an MTT (3-(4,5-dimethylthiazol-2-yl)-2,5- diphenyltetrazolium bromide) assay. The cell lines studied were primary mouse connective tissue cells (adhesive) and human leukemia cells (suspended). SPION were synthesized with a co-precipitation method under different stirring rates and NaOH molarities. The SPION demonstrated a range of magnetic saturations due to their...