Loading...
Search for: muscle
0.012 seconds
Total 220 records

    A model-based approach for estimation of changes in lumbar segmental kinematics associated with alterations in trunk muscle forces

    , Article Journal of Biomechanics ; Volume 70 , March , 2018 , Pages 82-87 ; 00219290 (ISSN) Shojaei, I ; Arjmand, N ; Meakin, J ; Bazrgari, B ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    The kinematics information from imaging, if combined with optimization-based biomechanical models, may provide a unique platform for personalized assessment of trunk muscle forces (TMFs). Such a method, however, is feasible only if differences in lumbar spine kinematics due to differences in TMFs can be captured by the current imaging techniques. A finite element model of the spine within an optimization procedure was used to estimate segmental kinematics of lumbar spine associated with five different sets of TMFs. Each set of TMFs was associated with a hypothetical trunk neuromuscular strategy that optimized one aspect of lower back biomechanics. For each set of TMFs, the segmental... 

    Effects of motion segment simulation and joint positioning on spinal loads in trunk musculoskeletal models

    , Article Journal of Biomechanics ; Volume 70 , March , 2018 , Pages 149-156 ; 00219290 (ISSN) Ghezelbash, F ; Eskandari, A. H ; Shirazi Adl, A ; Arjmand, N ; El-Ouaaid, Z ; Plamondon, A ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    Musculoskeletal models represent spinal motion segments by spherical joints/beams with linear/nonlinear properties placed at various locations. We investigated the fidelity of these simplified models (i.e., spherical joints with/without rotational springs and beams considering nonlinear/linear properties) in predicting kinematics of the ligamentous spine in comparison with a detailed finite element (FE) model while considering various anterior-posterior joint placements. Using the simplified models with different joint offsets in a subject-specific musculoskeletal model, we computed local spinal forces during forward flexion and compared results with intradiscal pressure measurements. In... 

    Trunk musculoskeletal response in maximum voluntary exertions: a combined measurement-modeling investigation

    , Article Journal of Biomechanics ; Volume 70 , March , 2018 , Pages 124-133 ; 00219290 (ISSN) Ghezelbash, F ; El Ouaaid, Z ; Shirazi Adl, A ; Plamondon, A ; Arjmand, N ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    Maximum voluntary exertion (MVE) tasks quantify trunk strength and maximal muscle electromyography (EMG) activities with both clinical and biomechanical implications. The aims here are to evaluate the performance of an existing trunk musculoskeletal model, estimate maximum muscle stresses and spinal forces, and explore likely differences between males and females in maximum voluntary exertions. We, therefore, measured trunk strength and EMG activities of 19 healthy right-handed subjects (9 females and 10 males) in flexion, extension, lateral and axial directions. MVEs for all subjects were then simulated in a subject-specific trunk musculoskeletal model, and estimated muscle activities were... 

    Can lumbosacral orthoses cause trunk muscle weakness? A systematic review of literature

    , Article Spine Journal ; Volume 17, Issue 4 , 2017 , Pages 589-602 ; 15299430 (ISSN) Azadinia, F ; Ebrahimi Takamjani, E ; Kamyab, M ; Parnianpour, M ; Cholewicki, J ; Maroufi, N ; Sharif University of Technology
    Elsevier Inc  2017
    Abstract
    Background Wearing lumbosacral orthosis (LSO) is one of the most common treatments prescribed for conservative management of low back pain. Although the results of randomized controlled trials suggest effectiveness of LSO in reducing pain and disability in these patients, there is a concern that prolonged use of LSO may lead to trunk muscle weakness and atrophy. Purpose The present review aimed to evaluate available evidence in literature to determine whether LSO results in trunk muscle weakness or atrophy. Study Design This is a systematic review. Methods A systematic search of electronic databases including PubMed, Scopus, ScienceDirect, and Medline (via Ovid) followed by hand search of... 

    Nonlinear optimal control of planar musculoskeletal arm model with minimum muscles stress criterion

    , Article Journal of Computational and Nonlinear Dynamics ; Volume 12, Issue 1 , 2017 ; 15551415 (ISSN) Sharifi, M ; Salarieh, H ; Behzadipour, S ; Sharif University of Technology
    American Society of Mechanical Engineers (ASME)  2017
    Abstract
    In this paper, the optimal performance of a planar humanlike musculoskeletal arm is investigated during reaching movements employing an optimal control policy. The initial and final states (position and velocity) are the only known data of the response trajectory. Two biomechanical objective functions are taken into account to be minimized as the central nervous system (CNS) strategy: (1) a quadratic function of muscle stresses (or forces), (2) total time of movement plus a quadratic function of muscle stresses. A two-degress of freedom (DOF) nonlinear musculoskeletal arm model (for planar movements) with six muscle actuators and four state variables is used in order to evaluate the proposed... 

    A combined passive and active musculoskeletal model study to estimate L4-L5 load sharing

    , Article Journal of Biomechanics ; 2017 ; 00219290 (ISSN) Azari, F ; Arjmand, N ; Shirazi Adl, A ; Rahimi Moghaddam, T ; Sharif University of Technology
    Elsevier Ltd  2017
    Abstract
    A number of geometrically-detailed passive finite element (FE) models of the lumbar spine have been developed and validated under in vitro loading conditions. These models are devoid of muscles and thus cannot be directly used to simulate in vivo loading conditions acting on the lumbar joint structures or spinal implants. Gravity loads and muscle forces estimated by a trunk musculoskeletal (MS) model under twelve static activities were applied to a passive FE model of the L4-L5 segment to estimate load sharing among the joint structures (disc, ligaments, and facets) under simulated in vivo loading conditions. An equivalent follower (FL), that generates IDP equal to that generated by muscle... 

    A Mechanobiological model for damage-induced growth in arterial tissue with application to in-stent restenosis

    , Article Journal of the Mechanics and Physics of Solids ; Volume 101 , 2017 , Pages 311-327 ; 00225096 (ISSN) Fereidoonnezhad, B ; Naghdabadi, R ; Sohrabpour, S ; Holzapfel, G. A ; Sharif University of Technology
    Elsevier Ltd  2017
    Abstract
    In-stent restenosis (ISR) is one of the main drawbacks of stent implementation which limits the long-term success of the procedure. Morphological changes occurring within the arterial wall due to stent-induced mechanical injury are a major cause for activation of vascular smooth muscle cells (VSMCs), and the subsequent development of ISR. Considering the theory of volumetric mass growth and adopting a multiplicative decomposition of the deformation gradient into an elastic part and a growth part, we present a mechanobiological model for ISR. An evolution equation is developed for mass growth of the neointima, in which the activation of VSMCs due to stent-induced damage (injury) and the... 

    A model-based approach for estimation of changes in lumbar segmental kinematics associated with alterations in trunk muscle forces

    , Article Journal of Biomechanics ; 2017 ; 00219290 (ISSN) Shojaei, I ; Arjmand, N ; Meakin, J. R ; Bazrgari, B ; Sharif University of Technology
    Elsevier Ltd  2017
    Abstract
    The kinematics information from imaging, if combined with optimization-based biomechanical models, may provide a unique platform for personalized assessment of trunk muscle forces (TMFs). Such a method, however, is feasible only if differences in lumbar spine kinematics due to differences in TMFs can be captured by the current imaging techniques. A finite element model of the spine within an optimization procedure was used to estimate segmental kinematics of lumbar spine associated with five different sets of TMFs. Each set of TMFs was associated with a hypothetical trunk neuromuscular strategy that optimized one aspect of lower back biomechanics. For each set of TMFs, the segmental... 

    A model for flexi-bar to evaluate intervertebral disc and muscle forces in exercises

    , Article Medical Engineering and Physics ; Volume 38, Issue 10 , 2016 , Pages 1076-1082 ; 13504533 (ISSN) Abdollahi, M ; Nikkhoo, M ; Ashouri, S ; Asghari, M ; Parnianpour, M ; Khalaf, K ; Sharif University of Technology
    Elsevier Ltd  2016
    Abstract
    This study developed and validated a lumped parameter model for the FLEXI-BAR, a popular training instrument that provides vibration stimulation. The model which can be used in conjunction with musculoskeletal-modeling software for quantitative biomechanical analyses, consists of 3 rigid segments, 2 torsional springs, and 2 torsional dashpots. Two different sets of experiments were conducted to determine the model's key parameters including the stiffness of the springs and the damping ratio of the dashpots. In the first set of experiments, the free vibration of the FLEXI-BAR with an initial displacement at its end was considered, while in the second set, forced oscillations of the bar were... 

    Design, fabrication and characterization of oxidized alginate-gelatin hydrogels for muscle tissue engineering applications

    , Article Journal of Biomaterials Applications ; Volume 31, Issue 1 , 2016 , Pages 152-161 ; 08853282 (ISSN) Baniasadi, H ; Mashayekhan, S ; Fadaoddini, S ; Haghirsharifzamini, Y ; Sharif University of Technology
    SAGE Publications Ltd  2016
    Abstract
    In this study, we reported the preparation of self cross-linked oxidized alginate-gelatin hydrogels for muscle tissue engineering. The effect of oxidation degree (OD) and oxidized alginate/gelatin (OA/GEL) weight ratio were examined and the results showed that in the constant OA/GEL weight ratio, both cross-linking density and Young's modulus enhanced by increasing OD due to increment of aldehyde groups. Furthermore, the degradation rate was increased with increasing OD probably due to decrement in alginate molecular weight during oxidation reaction facilitated degradation of alginate chains. MTT cytotoxicity assays performed on Wharton's Jelly-derived umbilical cord mesenchymal stem cells... 

    Electromyographic analysis of anterior cruciate deficient knees with and without functional bracing during lunge exercise

    , Article Prosthetics and Orthotics International ; Volume 40, Issue 2 , 2016 , Pages 270-276 ; 03093646 (ISSN) Jalali, M ; Farahmand, F ; Rezaeian, T ; Ramsey, D. K ; Mousavi, S. M. E ; Sharif University of Technology
    SAGE Publications Inc  2016
    Abstract
    Background: The use of functional knee braces for returning to sports or during demanding activities following anterior cruciate ligament rupture is common; yet despite being commonly prescribed, its mechanism of action remains unknown. Objectives: To examine the effect of functional knee braces on mean muscle activity when performing lunge exercises. Study design: Pre-/post-test (within-subject research design). Methods: A total of 10 male participants with unilateral isolated anterior cruciate ligament deficiency participated. Electromyographic activities of six muscles around the knee were recorded during lunge exercises, with and without wearing a custom functional knee brace. The lunge... 

    The gait and energy efficiency of stance control knee-ankle-foot orthoses: A literature review

    , Article Prosthetics and Orthotics International ; Volume 40, Issue 2 , 2016 , Pages 202-214 ; 03093646 (ISSN) Rafiaei, M ; Bahramizadeh, M ; Arazpour, M ; Samadian, M ; Hutchins, S. W ; Farahmand, F ; Mardani, M. A ; Sharif University of Technology
    SAGE Publications Inc  2016
    Abstract
    Background: The use of knee-ankle-foot orthoses with drop locked knee joints produces some limitations for walking in subjects with quadriceps muscle weakness. The development of stance control orthoses can potentially improve their functionality. Objectives: The aim of this review was to compare the evidence of the effect of stance control orthoses to knee-ankle-foot orthoses with drop locked knee joints in improving kinematic variables and energy efficiency of walking by subjects with quadriceps muscle weakness caused by different pathologies. Study design: Literature review. Methods: Based on selected keywords and their composition, a search was performed in Google Scholar, PubMed,... 

    Investigation of trunk muscle activities during lifting using a multi-objective optimization-based model and intelligent optimization algorithms

    , Article Medical and Biological Engineering and Computing ; Volume 54, Issue 2-3 , 2016 , Pages 431-440 ; 01400118 (ISSN) Ghiasi, M. S ; Arjmand, N ; Boroushaki, M ; Farahmand, F ; Sharif University of Technology
    Springer Verlag  2016
    Abstract
    A six-degree-of-freedom musculoskeletal model of the lumbar spine was developed to predict the activity of trunk muscles during light, moderate and heavy lifting tasks in standing posture. The model was formulated into a multi-objective optimization problem, minimizing the sum of the cubed muscle stresses and maximizing the spinal stability index. Two intelligent optimization algorithms, i.e., the vector evaluated particle swarm optimization (VEPSO) and nondominated sorting genetic algorithm (NSGA), were employed to solve the optimization problem. The optimal solution for each task was then found in the way that the corresponding in vivo intradiscal pressure could be reproduced. Results... 

    The different fate of satellite cells on conductive composite electrospun nanofibers with graphene and graphene oxide nanosheets

    , Article Biomedical Materials (Bristol) ; Volume 11, Issue 2 , 2016 ; 17486041 (ISSN) Mahmoudifard, M ; Soleimani, M ; Hatamie, S ; Zamanlui, S ; Ranjbarvan, P ; Vossoughi, M ; Hosseinzadeh, S ; Sharif University of Technology
    Institute of Physics Publishing  2016
    Abstract
    Electrospinning of composite polymer solutions provides fantastic potential to prepare novel nanofibers for use in a variety of applications. The addition of graphene (G) and graphene oxide (GO) nanosheets to bioactive polymers was found to enhance their conductivity and biocompatibility. Composite conductive nanofibers of polyaniline (PANI) and polyacrylonitrile (PAN) with G and GO nanosheets were prepared by an electrospinning process. The fabricated membranes were investigated by physical and chemical examinations including scanning electron microscopy (SEM), Raman spectroscopy, x-ray diffraction (XRD) and tensile assay. The muscle satellite cells enriched by a pre-plating technique were... 

    Effect of intervertebral translational flexibilities on estimations of trunk muscle forces, kinematics, loads, and stability

    , Article Computer Methods in Biomechanics and Biomedical Engineering ; Volume 18, Issue 16 , Sep , 2015 , Pages 1760-1767 ; 10255842 (ISSN) Ghezelbash, F ; Arjmand, N ; Shirazi Adl, A ; Sharif University of Technology
    Taylor and Francis Ltd  2015
    Abstract
    Due to the complexity of the human spinal motion segments, the intervertebral joints are often simulated in the musculoskeletal trunk models as pivots thus allowing no translational degrees of freedom (DOFs). This work aims to investigate, for the first time, the effect of such widely used assumption on trunk muscle forces, spinal loads, kinematics, and stability during a number of static activities. To address this, the shear deformable beam elements used in our nonlinear finite element (OFE) musculoskeletal model of the trunk were either substantially stiffened in translational directions (SFE model) or replaced by hinge joints interconnected through rotational springs (HFE model). Results... 

    An optimization-based method for prediction of lumbar spine segmental kinematics from the measurements of thorax and pelvic kinematics

    , Article International Journal for Numerical Methods in Biomedical Engineering ; July , 2015 , Volume 31, Issue 12 ; 20407939 (ISSN) Shojaei, I ; Arjmand, N ; Bazrgari, B ; Sharif University of Technology
    Wiley-Blackwell  2015
    Abstract
    Given measurement difficulties, earlier modeling studies have often used some constant ratios to predict lumbar segmental kinematics from measurements of total lumbar kinematics. Recent imaging studies suggested distribution of lumbar kinematics across its vertebrae changes with trunk rotation, lumbar posture, and presence of load. An optimization-based method is presented and validated in this study to predict segmental kinematics from measured total lumbar kinematics. Specifically, a kinematics-driven biomechanical model of the spine is used in a heuristic optimization procedure to obtain a set of segmental kinematics that, when prescribed to the model, were associated with the minimum... 

    Subject-specific and function-specific applicability of a hand-forearm musculoskeletal model

    , Article Biomedical Engineering - Applications, Basis and Communications ; Volume 27, Issue 6 , 2015 ; 10162372 (ISSN) Hosseininejad, S ; Farahmand, F ; Fateh, H. R ; Forogh, B ; Sharif University of Technology
    World Scientific Publishing Co. Pte Ltd  2015
    Abstract
    There is ambiguity on the quantitative validity of the predictions revealed by musculoskeletal models for muscle forces. This study investigated the consistency between the predictions of a musculoskeletal model of the upper limb and the experimental data for a number of different subjects and functional tasks. Six normal subjects performed isokinetic eccentric or isotonic concentric contraction tests of the wrist muscles in well controlled conditions, using a robotic apparatus, and the net joint torque and angular velocities, as well as the surface electromyograms (EMG) signals of the muscles, were recorded. The experiments were then simulated using a parametric musculoskeletal model of... 

    Interictal EEG denoising using independent component analysis and empirical mode decomposition

    , Article 2015 38th International Conference on Telecommunications and Signal Processing, TSP 2015, 9 July 2015 through 11 July 2015 ; July , 2015 , Page(s): 1 - 6 ; 9781479984985 (ISBN) Salsabili, S ; Sardoui, S. H ; Shamsollahi, M. B ; Molnar K ; Herencsar N ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    Noise contamination is inevitable in biomedical recordings. In some cases biomedical recordings are highly contaminated with artifacts which make the effective recovering process hard to achieve. Many different methods have been proposed for artifact removal from biomedical signals but introducing an effective method which can present valuable data for medical analysis, is still an ongoing process. In this paper a new method for interictal EEG denoising is presented. Single-channel ICA denoising method based on EMD decomposition is used to improve the multi-channel ICA denoising results. This method is tested on simulated epileptic recordings which are contaminated with real muscle artifact... 

    Is there a reliable and invariant set of muscle synergy during isometric biaxial trunk exertion in the sagittal and transverse planes by healthy subjects?

    , Article Journal of Biomechanics ; Volume 48, Issue 12 , Sep , 2015 , Pages 3234-3241 ; 00219290 (ISSN) Sedaghat Nejad, E ; Mousavi, S. J ; Hadizadeh, M ; Narimani, R ; Khalaf, K ; Campbell Kyureghyan, N ; Parnianpour, M ; Sharif University of Technology
    Elsevier Ltd  2015
    Abstract
    It has been suggested that the central nervous system simplifies muscle control through basic units, called synergies. In this study, we have developed a novel target-matching protocol and used non-negative matrix factorization (NMF) technique to extract trunk muscle synergies and corresponding torque synergies. Isometric torque data at the L5/S1 level and electromyographic patterns of twelve abdominal and back muscles from twelve healthy participants (five females) were simultaneously recorded. Each participant performed a total number of 24 isometric target-matching tasks using 12 different angular directions and 2 levels of uniaxial and biaxial exertions. Within- and between-subject... 

    Chitosan-gelatin sheets as scaffolds for muscle tissue engineering

    , Article Artificial Cells, Nanomedicine and Biotechnology ; Volume 43, Issue 2 , Nov , 2015 , Pages 124-132 ; 21691401 (ISSN) Hajiabbas, M ; Mashayekhan, S ; Nazaripouya, A ; Naji, M ; Hunkeler, D ; Rajabi Zeleti, S ; Sharifiaghdas, F ; Sharif University of Technology
    Informa Healthcare  2015
    Abstract
    Hydrogels made of natural polymers [chitosan (CS) and gelatin (G)] have been prepared having mechanical properties similar to those of muscle tissues. In this study, the effect of polymer concentration and scaffold stiffness on the behavior of seeded muscle-derived cells (MDCs) on the CS-G hydrogel sheets has been evaluated. Both variables were found to be important in cell viability. Viability was assessed by observation of the cell morphology after 1 day as well as a 14-day MTT assay. The CS-G hydrogels were characterized using Fourier transform infrared (FTIR) analysis, which revealed evidences of strong intermolecular interactions between CS and G. Hydrogel samples with intermediate...