Loading...
Search for: thermal-resistance
0.006 seconds
Total 23 records

    Investigation and visualization of surfactant effect on flow pattern and performance of pulsating heat pipe

    , Article Journal of Thermal Analysis and Calorimetry ; Volume 139, Issue 3 , 2020 , Pages 2099-2107 Gandomkar, A ; Kalan, K ; Vandadi, M ; Shafii, M. B ; Saidi, M. H ; Sharif University of Technology
    Springer Netherlands  2020
    Abstract
    Pulsating heat pipes (PHPs) are one of the new devices used for cooling in several applications such as electronic and aerospace systems. Their low cost, effectiveness at various conditions, being equipped for passive energy conversion, and well distribution of temperature compared to conventional heat pipes are among the reasons of their popularity. To investigate the effect of surface tension of the working fluid on the behavior of PHPs, a copper heat pipe is fabricated with inner and outer diameters of 2 mm and 4 mm, respectively. Five different concentrations of cetrimonium bromide (C-Tab) surfactant are dissolved in water and are tested with a filling ratio of 50% (± 1%). A piece of... 

    Developing a metamodel based upon the DOE approach for investigating the overall performance of microchannel heat sinks utilizing a variety of internal fins

    , Article International Journal of Heat and Mass Transfer ; Volume 149 , 2020 Hosseinpour, V ; Kazemeini, M ; Rashidi, A ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    In this study, the effects of geometry and operating conditions upon the thermal and hydraulic performance of Finned Microchannel Heat Sink (FMCHS) were investigated. Water and aluminum were considered as fluid and solid for the computational domain (30 mm × 0.8 mm × 0.8 mm). The Microchannel (MC) was supposed to have 0.65 mm height with an aspect ratio of 0.5. CFD analysis was applied for the assessments of four-types of micro-fins (i.e., conical, pyramidal, cylindrical and cubical). In order to evaluate the effects of height, diameter, the spacing of fins and Reynolds number on the overall performance of FMCHS, central composite design at five levels was used to generate design points.... 

    Effect of working fluid inventory and heat input on transient and steady state behavior of a thermosyphon

    , Article Journal of Thermal Analysis and Calorimetry ; 2020 Sadrameli, S. M ; Forootan, D ; Farajimoghaddam, F ; Sharif University of Technology
    Springer Netherlands  2020
    Abstract
    The effect of working fluid inventory and heat input on the performance of thermosyphon is investigated in this paper. First, a thermosyphon with diameter of 16 mm made of steel with toluene as working fluid and the length of the evaporator, adiabatic and condenser section 10, 23 and 17 cm was considered, respectively. The working fluid inventory was considered 0.1, 0.14, 0.18 and 0.24 of total volume of thermosyphon and in each case 54–235 W of heat input applied to the evaporator area also. In order to evaluate the transient behavior of the thermosyphon, in any amount of working fluid, 28 W of heat input was considered and temperature of the evaporator area were recorded at different...