- Microbial electrolysis cell is a novel technology for hydrogen production. The biggest challenges for this new technology are low rate of hydrogen production and high investment cost.
In this research, catholite condition was investigated for increasing the rate of hydrogen production. Low price stainless steel was used as cathode electrod. The microbial electrolysis cell operated applying 1.3 v external voltage. Basic pH was found to be the best condition for maximum rate of hydrogen production, where the average rate of hydrogen production was 100.006 1.866 L/m3.d. However, the hydrogen production rate for the acidic and neutral cathodic condition, were 92.89 1.13 and 91.845 1.485 L/m3.d, respectively. The cathodic hydrogen recovery for basic pH was 59.569 0.149% and the columbic efficiency was higher than other pH conditions, equal to 3.183 0.166% - Keywords:
- Microbial Electrolysis Cell ; Cathodes ; 316 Austenitic Stainless Steel ; PH ; Cathodic Hydrogen Recovery ; Columbic Efficiency
- محتواي کتاب