Loading...
A new three phase time-domain model for electric arc furnaces using MATLAB
Mokhtari, H ; Sharif University of Technology | 2002
145
Viewed
- Type of Document: Article
- Publisher: 2002
- Abstract:
- This paper presents a new time domain model for electric arc furnaces using MATLAB, The model can simulate both nonlinear and time varying nature of such loads, which create flicker, harmonics, and voltage/current unbalance. In this model, Cassie and Mayr equations are used in three-phase mode and the effects of arc furnace transformer tap changer and flexible cables mutual inductances are considered. The proposed model takes into account the system inter-relation of parameters and arcing conditions as well
- Keywords:
- Electric Arc Furnace ; Flicker ; Harmonic ; Power Quality ; Voltage/Current Unbalance
- Source: IEEE/PES Transmission and Distribution Conference and Exhibition 2002 : Asia Pacific, Yokahama, 6 October 2002 through 10 October 2002 ; Volume 3, Issue ASIA PACIFIC , 2002 , Pages 2078-2083
- URL: https://ieeexplore.ieee.org/abstract/document/1177781