Loading...
Search for: signal-processing--computer-assisted
0.008 seconds
Total 33 records

    Experimental feasibility study of estimation of the normalized central blood pressure waveform from radial photoplethysmogram

    , Article Journal of Healthcare Engineering ; Volume 6, Issue 1 , 2015 , Pages 121-144 ; 20402295 (ISSN) Zahedi, E ; Sohani, V ; Mohd. Ali, M. A ; Chellappan, K ; Beng, G. K ; Sharif University of Technology
    Multi-Science Publishing Co. Ltd  2015
    Abstract
    The feasibility of a novel system to reliably estimate the normalized central blood pressure (CBPN) from the radial photoplethysmogram (PPG) is investigated. Right-wrist radial blood pressure and left-wrist PPG were simultaneously recorded in five different days. An industry-standard applanation tonometer was employed for recording radial blood pressure. The CBP waveform was amplitude-normalized to determine CBPN. A total of fifteen second-order autoregressive models with exogenous input were investigated using system identification techniques. Among these 15 models, the model producing the lowest coefficient of variation (CV) of the fitness during the five days was... 

    Applicability of adaptive noise cancellation to fetal heart rate detection using photoplethysmography

    , Article Computers in Biology and Medicine ; Volume 38, Issue 1 , 2008 , Pages 31-41 ; 00104825 (ISSN) Zahedi, E ; Beng, G. K ; Sharif University of Technology
    2008
    Abstract
    In this paper, an approach based on adaptive noise cancellation (ANC) is evaluated for extraction of the fetal heart rate using photoplethysmographic signals from the maternal abdomen. A simple optical model is proposed in which the maternal and fetal blood pulsations result in emulated signals where the lower SNR limit (fetal to maternal) is - 25 dB. It is shown that a recursive least-squares algorithm is capable of extracting the peaks of the fetal PPG from these signals, for typical values of maternal and fetal tissues. © 2007 Elsevier Ltd. All rights reserved  

    Sequential blind source extraction for quasi-periodic signals with time-varying period

    , Article IEEE Transactions on Biomedical Engineering ; Volume 56, Issue 3 , 2009 , Pages 646-655 ; 00189294 (ISSN) Tsalaile, T ; Sameni, R ; Sanei, S ; Jutten, C ; Chambers, J ; Sharif University of Technology
    2009
    Abstract
    A novel second-order-statistics-based sequential blind extraction algorithm for blind extraction of quasi-periodic signals, with time-varying period, is introduced in this paper. Source extraction is performed by sequentially converging to a solution that effectively diagonalizes autocorrelation matrices at lags corresponding to the time-varying period, which thereby explicitly exploits a key statistical nonstationary characteristic of the desired source. The algorithm is shown to have fast convergence and yields significant improvement in signal-to-interference ratio as compared to when the algorithm assumes a fixed period. The algorithm is further evaluated on the problem of separation of... 

    All-optical controlled switching in centrally coupled circular array of nonlinear optical fibers

    , Article Applied Optics ; Volume 52, Issue 25 , Sep , 2013 , Pages 6131-6137 ; 1559128X (ISSN) Tofighi, S ; Bahrampour, A. R ; Sharif University of Technology
    Optical Society of American (OSA)  2013
    Abstract
    We show that, in a nonlinear centrally coupled circular array of evanescently coupled fibers, the coupling dynamics of a weak signal beam can be efficiently influenced by a high-power control beam that induces nonlinear defects. When the intense control beam is launched into the central core and one core in the periphery, then localized solitons are formed and cause the fibers with induced defects (defected fibers) to decouple from the other array elements. In the presence of a high-intensity control beam, the propagation of weak signal is restricted to the defected optical fibers. The weak signal periodically couples between the induced defects. This oscillatory behavior depends on the sign... 

    The effect of exertion level on activation patterns and variability of trunk muscles during multidirectional isometric activities in upright posture

    , Article Spine ; Volume 35, Issue 11 , May , 2010 , Pages E443-E451 ; 03622436 (ISSN) Talebian, S ; Mousavi, S. J ; Olyaei, G. R ; Sanjari, M. A ; Parnianpour, M ; Sharif University of Technology
    2010
    Abstract
    STUDY DESIGN.: An experimental design to investigate activation patterns of trunk muscles during multidirectional exertions. OBJECTIVES.: To evaluate trunk muscle activation patterns in varying directions and moment magnitudes during an isometric task, and to investigate the effects of angle and level of isometric exertion on the electromyography (EMG) variability of trunk muscles in upright posture. SUMMARY OF BACKGROUND DATA.: Few studies have investigated trunk muscle activation patterns in multidirectional exertions with different moment magnitudes. METHODS.: A total of 12 asymptomatic male subjects were participated in the study. The EMG activity of 10 selected trunk muscles was... 

    Digital implementation of a biological astrocyte model and its application

    , Article IEEE Transactions on Neural Networks and Learning Systems ; Volume 26, Issue 1 , 2014 , Pages 127-139 ; 2162237X (ISSN) Soleimani, H ; Bavandpour, M ; Ahmadi, A ; Abbott, D ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2014
    Abstract
    This paper presents a modified astrocyte model that allows a convenient digital implementation. This model is aimed at reproducing relevant biological astrocyte behaviors, which provide appropriate feedback control in regulating neuronal activities in the central nervous system. Accordingly, we investigate the feasibility of a digital implementation for a single astrocyte and a biological neuronal network model constructed by connecting two limit-cycle Hopf oscillators to an implementation of the proposed astrocyte model using oscillator-astrocyte interactions with weak coupling. Hardware synthesis, physical implementation on field-programmable gate array, and theoretical analysis confirm... 

    Utility of a nonlinear joint dynamical framework to model a pair of coupled cardiovascular signals

    , Article IEEE Journal of Biomedical and Health Informatics ; Volume 17, Issue 4 , 2013 , Pages 881-890 ; 21682194 (ISSN) Sayadi, O ; Shamsollahi, M. B ; Sharif University of Technology
    2013
    Abstract
    We have recently proposed a correlated model to provide a Gaussian mixture representation of the cardiovascular signals, with promising results in identifying rhythm disturbances. The approach provides a transformation of the data into a set of integrable Gaussians distributed over time. Looking into the model from a new joint modeling perspective, it is capable of assembling a filtered estimation, and can be used to derive temporal information of the waveforms. In this paper, we present a step-by-step derivation of the joint model putting correlation assumptions together to conclude a minimal joint description for a pair of ECG-ABP signals. We then probe novel applications of this model,... 

    Life-threatening arrhythmia verification in ICU patients using the joint cardiovascular dynamical model and a bayesian filter

    , Article IEEE Transactions on Biomedical Engineering ; Volume 58, Issue 10 PART 1 , 2011 , Pages 2748-2757 ; 00189294 (ISSN) Sayadi, O ; Shamsollahi, M. B ; Sharif University of Technology
    Abstract
    In this paper, a novel nonlinear joint dynamical model is presented, which is based on a set of coupled ordinary differential equations of motion and a Gaussian mixture model representation of pulsatile cardiovascular (CV) signals. In the proposed framework, the joint interdependences of CV signals are incorporated by assuming a unique angular frequency that controls the limit cycle of the heart rate. Moreover, the time consequence of CV signals is controlled by the same phase parameter that results in the space dimensionality reduction. These joint equations together with linear assignments to observation are further used in the Kalman filter structure for estimation and tracking. Moreover,... 

    Robust detection of premature ventricular contractions using a wave-based Bayesian framework

    , Article IEEE transactions on bio-medical engineering ; Volume 57, Issue 2 , September , 2010 , Pages 353-362 ; 15582531 (ISSN) Sayadi, O ; Shamsollahi, M. B ; Clifford, G. D ; Sharif University of Technology
    2010
    Abstract
    Detection and classification of ventricular complexes from the ECG is of considerable importance in Holter and critical care patient monitoring, being essential for the timely diagnosis of dangerous heart conditions. Accurate detection of premature ventricular contractions (PVCs) is particularly important in relation to life-threatening arrhythmias. In this paper, we introduce a model-based dynamic algorithm for tracking the ECG characteristic waveforms using an extended Kalman filter. The algorithm can work on single or multiple leads. A "polargram"--a polar representation of the signal--is introduced, which is constructed using the Bayesian estimations of the state variables. The polargram... 

    A model-based Bayesian framework for ECG beat segmentation

    , Article Physiological Measurement ; Volume 30, Issue 3 , 2009 , Pages 335-352 ; 09673334 (ISSN) Sayadi, O ; Shamsollahi, M. B ; Sharif University of Technology
    2009
    Abstract
    The study of electrocardiogram (ECG) waveform amplitudes, timings and patterns has been the subject of intense research, for it provides a deep insight into the diagnostic features of the heart's functionality. In some recent works, a Bayesian filtering paradigm has been proposed for denoising and compression of ECG signals. In this paper, it is shown that this framework may be effectively used for ECG beat segmentation and extraction of fiducial points. Analytic expressions for the determination of points and intervals are derived and evaluated on various real ECG signals. Simulation results show that the method can contribute to and enhance the clinical ECG beat segmentation performance. ©... 

    ECG denoising using parameters of ECG dynamical model as the states of an extended Kalman filter

    , Article 29th Annual International Conference of IEEE-EMBS, Engineering in Medicine and Biology Society, EMBC'07, Lyon, 23 August 2007 through 26 August 2007 ; 2007 , Pages 2548-2551 ; 05891019 (ISSN) ; 1424407885 (ISBN); 9781424407880 (ISBN) Sayadi, O ; Sameni, R ; Shamsollahi, M. B ; Sharif University of Technology
    2007
    Abstract
    In this paper an efficient Altering procedure based on the Extended Kalman Filter (EKF) has been proposed. The method is based on a modified nonlinear dynamic model, previously introduced for the generation of synthetic ECG signals. We have suggested simple dynamics as the governing equations for the model parameters. Since we have not any observation for these new state variables, they are considered as hidden states. Quantitative evaluation of the proposed algorithm on the MIT-BIH signals shows that an average SNR improvement of 12 dB is achieved for a signal of -5 dB. The results show improved output SNRs compared to the EKF outputs in the absence of these new dynamics. © 2007 IEEE  

    Extraction and automatic grouping of joint and individual sources in multisubject fMRI data using higher order cumulants

    , Article IEEE Journal of Biomedical and Health Informatics ; Volume 23, Issue 2 , 2019 , Pages 744-757 ; 21682194 (ISSN) Pakravan, M ; Shamsollahi, M. B ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    The joint analysis of multiple data sets to extract their interdependency information has wide applications in biomedical and health informatics. In this paper, we propose an algorithm to extract joint and individual sources of multisubject data sets by using a deflation-based procedure, which is referred to as joint/individual thin independent component analysis (JI-ThICA). The proposed algorithm is based on two cost functions utilizing higher order cumulants to extract joint and individual sources. Joint sources are discriminated by fusing signals of all subjects, whereas individual sources are extracted separately for each subject. Furthermore, JI-ThICA algorithm estimates the number of... 

    A unified approach for detection of induced epileptic seizures in rats using ECoG signals

    , Article Epilepsy and Behavior ; Volume 27, Issue 2 , 2013 , Pages 355-364 ; 15255050 (ISSN) Niknazar, M ; Mousavi, S. R ; Motaghi, S ; Dehghani, A ; Vosoughi Vahdat, B ; Shamsollahi, M. B ; Sayyah, M ; Noorbakhsh, S. M ; Sharif University of Technology
    2013
    Abstract
    Objective: Epileptic seizure detection is a key step for epilepsy assessment. In this work, using the pentylenetetrazole (PTZ) model, seizures were induced in rats, and ECoG signals in interictal, preictal, ictal, and postictal periods were recorded. The recorded ECoG signals were then analyzed to detect epileptic seizures in the epileptic rats. Methods: Two different approaches were considered in this work: thresholding and classification. In the thresholding approach, a feature is calculated in consecutive windows, and the resulted index is tracked over time and compared with a threshold. The moment the index crosses the threshold is considered as the moment of seizure onset. In the... 

    Analysis of P300 classifiers in brain computer interface speller

    , Article 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06, New York, NY, 30 August 2006 through 3 September 2006 ; 2006 , Pages 6205-6208 ; 05891019 (ISSN); 1424400325 (ISBN); 9781424400324 (ISBN) Mirghasemi, H ; Fazel Rezai, R ; Shamsollahi, M. B ; Sharif University of Technology
    2006
    Abstract
    In this paper, the performance of five classifiers in P300 speller paradigm are compared. Theses classifiers are Linear Support Vector Machine (LSVM), Gaussian Support Vector Machine (RSVM), Neural Network (NN), Fisher Linear Discriminant (FLD), and Kernel Fisher Discriminant (KFD). In classification of P300 waves, there has been a trend to use SVM classifiers. Although they have shown a good performance, in this paper, it is shown that the FLD classifiers outperform the SVM classifiers. FLD classifier uses only ten channels of the recorded electroencephalogram (EEG) signals. This makes them a very good candidate for real-time applications. In addition, FLD approach does not need any... 

    Antepartum fetal heart rate feature extraction and classification using empirical mode decomposition and support vector machine

    , Article BioMedical Engineering Online ; Volume 10 , 2011 ; 1475925X (ISSN) Krupa, N ; MA, M. A ; Zahedi, E ; Ahmed, S ; Hassan, F. M ; Sharif University of Technology
    Abstract
    Background: Cardiotocography (CTG) is the most widely used tool for fetal surveillance. The visual analysis of fetal heart rate (FHR) traces largely depends on the expertise and experience of the clinician involved. Several approaches have been proposed for the effective interpretation of FHR. In this paper, a new approach for FHR feature extraction based on empirical mode decomposition (EMD) is proposed, which was used along with support vector machine (SVM) for the classification of FHR recordings as 'normal' or 'at risk'.Methods: The FHR were recorded from 15 subjects at a sampling rate of 4 Hz and a dataset consisting of 90 randomly selected records of 20 minutes duration was formed from... 

    The application of empirical mode decomposition for the enhancement of cardiotocograph signals

    , Article Physiological Measurement ; Volume 30, Issue 8 , 2009 , Pages 729-743 ; 09673334 (ISSN) Krupa, B. N ; Mohd Ali, M. A ; Zahedi, E ; Sharif University of Technology
    2009
    Abstract
    Cardiotocograph (CTG) is widely used in everyday clinical practice for fetal surveillance, where it is used to record fetal heart rate (FHR) and uterine activity (UA). These two biosignals can be used for antepartum and intrapartum fetal monitoring and are, in fact, nonlinear and non-stationary. CTG recordings are often corrupted by artifacts such as missing beats in FHR, high-frequency noise in FHR and UA signals. In this paper, an empirical mode decomposition (EMD) method is applied on CTG signals. A recursive algorithm is first utilized to eliminate missing beats. High-frequency noise is reduced using EMD followed by the partial reconstruction (PAR) method, where the noise order is... 

    An exploratory study to design a novel hand movement identification system

    , Article Computers in Biology and Medicine ; Volume 39, Issue 5 , 2009 , Pages 433-442 ; 00104825 (ISSN) Khezri, M ; Jahed, M ; Sharif University of Technology
    2009
    Abstract
    Electromyogram signal (EMG) is an electrical manifestation of contractions of muscles. Surface EMG (sEMG) signal collected from the surface of skin has been used in diverse applications. One of its usages is in pattern recognition of hand prosthesis movements. The ability of current prosthesis devices has been generally limited to simple opening and closing tasks, minimizing their efficacy compared to natural hand capabilities. In order to extend the abilities and accuracy of prosthesis arm movements and performance, a novel sEMG pattern recognizing system is proposed. To extract more pertinent information we extracted sEMGs for selected hand movements. These features constitute our main... 

    Surface Electromyogram signal estimation based on wavelet thresholding technique

    , Article 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08, Vancouver, BC, 20 August 2008 through 25 August 2008 ; 2008 , Pages 4752-4755 ; 9781424418152 (ISBN) Khezri, M ; Jahed, M ; Sharif University of Technology
    IEEE Computer Society  2008
    Abstract
    Surface Electromyogram signal collected from the surface of skin is a biopotential signal that may be influenced by different types of noise. This is a considerable drawback in the processing of the sEMG signals. To acquire the clean sEMG that contains useful information, we need to detect and eliminate these unwanted parts of signal. In this work, a new method based on wavelet thresholding technique is presented which provides an acceptable purified sEMG signal. sEMG signals for this study are extracted for various hand movements. We use three hand movements to calculate the near optimal estimation parameters. In this work two types of thresholding techniques, namely Stein unbiased risk... 

    Introducing a new multi-wavelet function suitable for sEMG signal to identify hand motion commands

    , Article 29th Annual International Conference of IEEE-EMBS, Engineering in Medicine and Biology Society, EMBC'07, Lyon, 23 August 2007 through 26 August 2007 ; 2007 , Pages 1924-1927 ; 05891019 (ISSN) ; 1424407885 (ISBN); 9781424407880 (ISBN) Khezri, M ; Jahed, M ; Sharif University of Technology
    2007
    Abstract
    In recent years, electromyogram signal (EMG) feature selection, based on wavelet transform, has received considerable attention. This study introduces a new multiwavelet function for surface EMG (sEMG) signal intended for tasks that involve hand movement recognition. To create the new wavelet function, several types of well known mother wavelet were exploited and through their integration the proposed mother wavelet was generated. The proposed wavelet function closely reproduced the characteristics of the EMG signal, while increasing the recognition accuracy of hand movements. We used eight unique classes of hand motions and considered the ability of various mother wavelets and the proposed... 

    EEG-based functional brain networks: does the network size matter?

    , Article PloS one ; Volume 7, Issue 4 , 2012 ; 19326203 (ISSN) Joudaki, A ; Salehi, N ; Jalili, M ; Knyazeva, M. G ; Sharif University of Technology
    PLOS  2012
    Abstract
    Functional connectivity in human brain can be represented as a network using electroencephalography (EEG) signals. These networks--whose nodes can vary from tens to hundreds--are characterized by neurobiologically meaningful graph theory metrics. This study investigates the degree to which various graph metrics depend upon the network size. To this end, EEGs from 32 normal subjects were recorded and functional networks of three different sizes were extracted. A state-space based method was used to calculate cross-correlation matrices between different brain regions. These correlation matrices were used to construct binary adjacency connectomes, which were assessed with regards to a number of...