Loading...
Search for: signal-processing--computer-assisted
0.018 seconds
Total 33 records

    Synchronization of EEG: Bivariate and multivariate measures

    , Article IEEE Transactions on Neural Systems and Rehabilitation Engineering ; Vol. 22, Issue. 2 , 2014 , pp. 212-221 ; ISSN: 1534-4320 Jalili, M ; Barzegaran, E ; Knyazeva, M. G ; Sharif University of Technology
    Abstract
    Synchronization behavior of electroencephalographic (EEG) signals is important for decoding information processing in the human brain. Modern multichannel EEG allows a transition from traditional measurements of synchronization in pairs of EEG signals to whole-brain synchronization maps. The latter can be based on bivariate measures (BM) via averaging over pair-wise values or, alternatively, on multivariate measures (MM), which directly ascribe a single value to the synchronization in a group. In order to compare BM versus MM, we applied nine different estimators to simulated multivariate time series with known parameters and to real EEGs. We found widespread correlations between BM and MM,... 

    Utility of a nonlinear joint dynamical framework to model a pair of coupled cardiovascular signals

    , Article IEEE Journal of Biomedical and Health Informatics ; Volume 17, Issue 4 , 2013 , Pages 881-890 ; 21682194 (ISSN) Sayadi, O ; Shamsollahi, M. B ; Sharif University of Technology
    2013
    Abstract
    We have recently proposed a correlated model to provide a Gaussian mixture representation of the cardiovascular signals, with promising results in identifying rhythm disturbances. The approach provides a transformation of the data into a set of integrable Gaussians distributed over time. Looking into the model from a new joint modeling perspective, it is capable of assembling a filtered estimation, and can be used to derive temporal information of the waveforms. In this paper, we present a step-by-step derivation of the joint model putting correlation assumptions together to conclude a minimal joint description for a pair of ECG-ABP signals. We then probe novel applications of this model,... 

    All-optical controlled switching in centrally coupled circular array of nonlinear optical fibers

    , Article Applied Optics ; Volume 52, Issue 25 , Sep , 2013 , Pages 6131-6137 ; 1559128X (ISSN) Tofighi, S ; Bahrampour, A. R ; Sharif University of Technology
    Optical Society of American (OSA)  2013
    Abstract
    We show that, in a nonlinear centrally coupled circular array of evanescently coupled fibers, the coupling dynamics of a weak signal beam can be efficiently influenced by a high-power control beam that induces nonlinear defects. When the intense control beam is launched into the central core and one core in the periphery, then localized solitons are formed and cause the fibers with induced defects (defected fibers) to decouple from the other array elements. In the presence of a high-intensity control beam, the propagation of weak signal is restricted to the defected optical fibers. The weak signal periodically couples between the induced defects. This oscillatory behavior depends on the sign... 

    A unified approach for detection of induced epileptic seizures in rats using ECoG signals

    , Article Epilepsy and Behavior ; Volume 27, Issue 2 , 2013 , Pages 355-364 ; 15255050 (ISSN) Niknazar, M ; Mousavi, S. R ; Motaghi, S ; Dehghani, A ; Vosoughi Vahdat, B ; Shamsollahi, M. B ; Sayyah, M ; Noorbakhsh, S. M ; Sharif University of Technology
    2013
    Abstract
    Objective: Epileptic seizure detection is a key step for epilepsy assessment. In this work, using the pentylenetetrazole (PTZ) model, seizures were induced in rats, and ECoG signals in interictal, preictal, ictal, and postictal periods were recorded. The recorded ECoG signals were then analyzed to detect epileptic seizures in the epileptic rats. Methods: Two different approaches were considered in this work: thresholding and classification. In the thresholding approach, a feature is calculated in consecutive windows, and the resulted index is tracked over time and compared with a threshold. The moment the index crosses the threshold is considered as the moment of seizure onset. In the... 

    EEG-based functional brain networks: does the network size matter?

    , Article PloS one ; Volume 7, Issue 4 , 2012 ; 19326203 (ISSN) Joudaki, A ; Salehi, N ; Jalili, M ; Knyazeva, M. G ; Sharif University of Technology
    PLOS  2012
    Abstract
    Functional connectivity in human brain can be represented as a network using electroencephalography (EEG) signals. These networks--whose nodes can vary from tens to hundreds--are characterized by neurobiologically meaningful graph theory metrics. This study investigates the degree to which various graph metrics depend upon the network size. To this end, EEGs from 32 normal subjects were recorded and functional networks of three different sizes were extracted. A state-space based method was used to calculate cross-correlation matrices between different brain regions. These correlation matrices were used to construct binary adjacency connectomes, which were assessed with regards to a number of... 

    Average consensus in networks of dynamic multi-agents with switching topology: Infinite matrix products

    , Article ISA Transactions ; Volume 51, Issue 4 , 2012 , Pages 522-530 ; 00190578 (ISSN) Atrianfar, H ; Haeri, M ; Sharif University of Technology
    2012
    Abstract
    This paper deals with the average consensus problem in a multi-agent system with switching interaction topology modeled as a weighted digraph. The convergence analysis is performed in both discrete-time and continuous-time dynamics based on the theory of infinite matrix products. Conditions for system convergence to average consensus are derived in the form of constraints on direct and reverse graphs and the structure of adjacency elements among the agents. Furthermore, a sufficient condition is provided for convergence to average consensus in systems in which the interaction topology is balanced over infinite contiguous non-overlapping time intervals instead of being balanced continuously.... 

    EEG-based functional networks in schizophrenia

    , Article Computers in Biology and Medicine ; Volume 41, Issue 12 , 2011 , Pages 1178-1186 ; 00104825 (ISSN) Jalili, M ; Knyazeva, M. G ; Sharif University of Technology
    2011
    Abstract
    Schizophrenia is often considered as a dysconnection syndrome in which, abnormal interactions between large-scale functional brain networks result in cognitive and perceptual deficits. In this article we apply the graph theoretic measures to brain functional networks based on the resting EEGs of fourteen schizophrenic patients in comparison with those of fourteen matched control subjects. The networks were extracted from common-average-referenced EEG time-series through partial and unpartial cross-correlation methods. Unpartial correlation detects functional connectivity based on direct and/or indirect links, while partial correlation allows one to ignore indirect links. We quantified the... 

    Life-threatening arrhythmia verification in ICU patients using the joint cardiovascular dynamical model and a bayesian filter

    , Article IEEE Transactions on Biomedical Engineering ; Volume 58, Issue 10 PART 1 , 2011 , Pages 2748-2757 ; 00189294 (ISSN) Sayadi, O ; Shamsollahi, M. B ; Sharif University of Technology
    Abstract
    In this paper, a novel nonlinear joint dynamical model is presented, which is based on a set of coupled ordinary differential equations of motion and a Gaussian mixture model representation of pulsatile cardiovascular (CV) signals. In the proposed framework, the joint interdependences of CV signals are incorporated by assuming a unique angular frequency that controls the limit cycle of the heart rate. Moreover, the time consequence of CV signals is controlled by the same phase parameter that results in the space dimensionality reduction. These joint equations together with linear assignments to observation are further used in the Kalman filter structure for estimation and tracking. Moreover,... 

    Constructing brain functional networks from EEG: Partial and unpartial correlations

    , Article Journal of Integrative Neuroscience ; Volume 10, Issue 2 , 2011 , Pages 213-232 ; 02196352 (ISSN) Jalili, M ; Knyazeva, M. G ; Sharif University of Technology
    Abstract
    We consider electroencephalograms (EEGs) of healthy individuals and compare the properties of the brain functional networks found through two methods: unpartialized and partialized cross-correlations. The networks obtained by partial correlations are fundamentally different from those constructed through unpartial correlations in terms of graph metrics. In particular, they have completely different connection efficiency, clustering coefficient, assortativity, degree variability, and synchronization properties. Unpartial correlations are simple to compute and they can be easily applied to large-scale systems, yet they cannot prevent the prediction of non-direct edges. In contrast, partial... 

    Antepartum fetal heart rate feature extraction and classification using empirical mode decomposition and support vector machine

    , Article BioMedical Engineering Online ; Volume 10 , 2011 ; 1475925X (ISSN) Krupa, N ; MA, M. A ; Zahedi, E ; Ahmed, S ; Hassan, F. M ; Sharif University of Technology
    Abstract
    Background: Cardiotocography (CTG) is the most widely used tool for fetal surveillance. The visual analysis of fetal heart rate (FHR) traces largely depends on the expertise and experience of the clinician involved. Several approaches have been proposed for the effective interpretation of FHR. In this paper, a new approach for FHR feature extraction based on empirical mode decomposition (EMD) is proposed, which was used along with support vector machine (SVM) for the classification of FHR recordings as 'normal' or 'at risk'.Methods: The FHR were recorded from 15 subjects at a sampling rate of 4 Hz and a dataset consisting of 90 randomly selected records of 20 minutes duration was formed from... 

    Denoising of ictal EEG data using semi-blind source separation methods based on time-frequency priors

    , Article IEEE Journal of Biomedical and Health Informatics ; Volume 19, Issue 3 , July , 2015 , Pages 839-847 ; 21682194 (ISSN) Hajipour Sardouie, S ; Shamsollahi, M. B ; Albera, L ; Merlet, I ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    Removing muscle activity from ictal ElectroEncephaloGram (EEG) data is an essential preprocessing step in diagnosis and study of epileptic disorders. Indeed, at the very beginning of seizures, ictal EEG has a low amplitude and its morphology in the time domain is quite similar to muscular activity. Contrary to the time domain, ictal signals have specific characteristics in the time-frequency domain. In this paper, we use the time-frequency signature of ictal discharges as a priori information on the sources of interest. To extract the time-frequency signature of ictal sources, we use the Canonical Correlation Analysis (CCA) method. Then, we propose two time-frequency based semi-blind source... 

    Digital implementation of a biological astrocyte model and its application

    , Article IEEE Transactions on Neural Networks and Learning Systems ; Volume 26, Issue 1 , 2014 , Pages 127-139 ; 2162237X (ISSN) Soleimani, H ; Bavandpour, M ; Ahmadi, A ; Abbott, D ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2014
    Abstract
    This paper presents a modified astrocyte model that allows a convenient digital implementation. This model is aimed at reproducing relevant biological astrocyte behaviors, which provide appropriate feedback control in regulating neuronal activities in the central nervous system. Accordingly, we investigate the feasibility of a digital implementation for a single astrocyte and a biological neuronal network model constructed by connecting two limit-cycle Hopf oscillators to an implementation of the proposed astrocyte model using oscillator-astrocyte interactions with weak coupling. Hardware synthesis, physical implementation on field-programmable gate array, and theoretical analysis confirm... 

    Experimental feasibility study of estimation of the normalized central blood pressure waveform from radial photoplethysmogram

    , Article Journal of Healthcare Engineering ; Volume 6, Issue 1 , 2015 , Pages 121-144 ; 20402295 (ISSN) Zahedi, E ; Sohani, V ; Mohd. Ali, M. A ; Chellappan, K ; Beng, G. K ; Sharif University of Technology
    Multi-Science Publishing Co. Ltd  2015
    Abstract
    The feasibility of a novel system to reliably estimate the normalized central blood pressure (CBPN) from the radial photoplethysmogram (PPG) is investigated. Right-wrist radial blood pressure and left-wrist PPG were simultaneously recorded in five different days. An industry-standard applanation tonometer was employed for recording radial blood pressure. The CBP waveform was amplitude-normalized to determine CBPN. A total of fifteen second-order autoregressive models with exogenous input were investigated using system identification techniques. Among these 15 models, the model producing the lowest coefficient of variation (CV) of the fitness during the five days was... 

    The effect of exertion level on activation patterns and variability of trunk muscles during multidirectional isometric activities in upright posture

    , Article Spine ; Volume 35, Issue 11 , May , 2010 , Pages E443-E451 ; 03622436 (ISSN) Talebian, S ; Mousavi, S. J ; Olyaei, G. R ; Sanjari, M. A ; Parnianpour, M ; Sharif University of Technology
    2010
    Abstract
    STUDY DESIGN.: An experimental design to investigate activation patterns of trunk muscles during multidirectional exertions. OBJECTIVES.: To evaluate trunk muscle activation patterns in varying directions and moment magnitudes during an isometric task, and to investigate the effects of angle and level of isometric exertion on the electromyography (EMG) variability of trunk muscles in upright posture. SUMMARY OF BACKGROUND DATA.: Few studies have investigated trunk muscle activation patterns in multidirectional exertions with different moment magnitudes. METHODS.: A total of 12 asymptomatic male subjects were participated in the study. The EMG activity of 10 selected trunk muscles was... 

    Robust detection of premature ventricular contractions using a wave-based Bayesian framework

    , Article IEEE transactions on bio-medical engineering ; Volume 57, Issue 2 , September , 2010 , Pages 353-362 ; 15582531 (ISSN) Sayadi, O ; Shamsollahi, M. B ; Clifford, G. D ; Sharif University of Technology
    2010
    Abstract
    Detection and classification of ventricular complexes from the ECG is of considerable importance in Holter and critical care patient monitoring, being essential for the timely diagnosis of dangerous heart conditions. Accurate detection of premature ventricular contractions (PVCs) is particularly important in relation to life-threatening arrhythmias. In this paper, we introduce a model-based dynamic algorithm for tracking the ECG characteristic waveforms using an extended Kalman filter. The algorithm can work on single or multiple leads. A "polargram"--a polar representation of the signal--is introduced, which is constructed using the Bayesian estimations of the state variables. The polargram... 

    Estimation of phase signal change in neuronal current MRI for evoke response of tactile detection with realistic somatosensory laminar network model

    , Article Australasian Physical and Engineering Sciences in Medicine ; Volume 39, Issue 3 , 2016 , Pages 717-726 ; 01589938 (ISSN) BagheriMofidi, S. M ; Pouladian, M ; Jameie, S. B ; Abbaspour Tehrani Fard, A ; Sharif University of Technology
    Springer Netherlands  2016
    Abstract
    Magnetic field generated by neuronal activity could alter magnetic resonance imaging (MRI) signals but detection of such signal is under debate. Previous researches proposed that magnitude signal change is below current detectable level, but phase signal change (PSC) may be measurable with current MRI systems. Optimal imaging parameters like echo time, voxel size and external field direction, could increase the probability of detection of this small signal change. We simulate a voxel of cortical column to determine effect of such parameters on PSC signal. We extended a laminar network model for somatosensory cortex to find neuronal current in each segment of pyramidal neurons (PN). 60,000... 

    ECG denoising using modulus maxima of wavelet transform

    , Article Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009 ; 2009 , Pages 416-419 ; 1557170X (ISSN) Ayat, M ; Shamsollahi, M. B ; Mozaffari, B ; Kharabian, S ; Sharif University of Technology
    Abstract
    ECG denoising has always been an important issue in medical engineering. The purposes of denoising are reducing noise level and improving signal to noise ratio (SNR) without distorting the signal. This paper proposes a method for removing white Gaussian noise from ECG signals. The concepts of singularity and local maxima of the wavelet transform modulus were used for analyzing singularity and reconstructing the ECG signal. Adaptive thresholding was used to remove white Gaussian noise modulus maximum of wavelet transform and then reconstruct the signal  

    Directed functional networks in Alzheimer's disease: disruption of global and local connectivity measures

    , Article IEEE Journal of Biomedical and Health Informatics ; Volume 21, Issue 4 , 2017 , Pages 949-955 ; 21682194 (ISSN) Afshari, S ; Jalili, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    Techniques available in graph theory can be applied to signals recorded from human brain. In network analysis of EEG signals, the individual nodes are EEG sensor locations and the edges correspond to functional relations between them that are extracted from EEG time series. In this paper, we study EEG-based directed functional networks in Alzheimer's disease (AD). To this end, directed connectivity matrices of 25 AD patients and 26 healthy subjects are processed and a number of meaningful graph theory metrics are studied. Our data show that functional networks of AD brains have significantly reduced global connectivity in alpha and beta bands (P < 0.05). The AD brains have significantly... 

    ECG fiducial point extraction using switching Kalman filter

    , Article Computer Methods and Programs in Biomedicine ; Volume 157 , 2018 , Pages 129-136 ; 01692607 (ISSN) Akhbari, M ; Montazeri Ghahjaverestan, N ; Shamsollahi, M. B ; Jutten, C ; Sharif University of Technology
    Elsevier Ireland Ltd  2018
    Abstract
    In this paper, we propose a novel method for extracting fiducial points (FPs) of the beats in electrocardiogram (ECG) signals using switching Kalman filter (SKF). In this method, according to McSharry's model, ECG waveforms (P-wave, QRS complex and T-wave) are modeled with Gaussian functions and ECG baselines are modeled with first order auto regressive models. In the proposed method, a discrete state variable called “switch” is considered that affects only the observation equations. We denote a mode as a specific observation equation and switch changes between 7 modes and corresponds to different segments of an ECG beat. At each time instant, the probability of each mode is calculated and... 

    Sequential blind source extraction for quasi-periodic signals with time-varying period

    , Article IEEE Transactions on Biomedical Engineering ; Volume 56, Issue 3 , 2009 , Pages 646-655 ; 00189294 (ISSN) Tsalaile, T ; Sameni, R ; Sanei, S ; Jutten, C ; Chambers, J ; Sharif University of Technology
    2009
    Abstract
    A novel second-order-statistics-based sequential blind extraction algorithm for blind extraction of quasi-periodic signals, with time-varying period, is introduced in this paper. Source extraction is performed by sequentially converging to a solution that effectively diagonalizes autocorrelation matrices at lags corresponding to the time-varying period, which thereby explicitly exploits a key statistical nonstationary characteristic of the desired source. The algorithm is shown to have fast convergence and yields significant improvement in signal-to-interference ratio as compared to when the algorithm assumes a fixed period. The algorithm is further evaluated on the problem of separation of...