Loading...
Search for: thermoelectric-equipment
0.013 seconds
Total 51 records

    A validated numerical-experimental design methodology for a movable supersonic ejector compressor for waste-heat recovery

    , Article Journal of Thermal Science and Engineering Applications ; Volume 6, Issue 2 , Oct , 2014 ; 19485085 (ISSN) Alimohammadi, S ; Persoons, T ; Murray, D. B ; Tehrani, M. S ; Farhanieh, B ; Koehler, J ; Sharif University of Technology
    Web Portal ASME (American Society of Mechanical Engineers)  2014
    Abstract
    The aim of this paper is to develop the technical knowledge, especially the optimum geometries, for the design and manufacturing of a supersonic gas-gas ejector for a wasteheat driven vehicle cooling system. Although several studies have been performed to investigate the effects of geometrical configurations of gas-gas ejectors, a progressive design methodology of an ejector compressor for application to a vehicle cooling system has not yet been described. First, an analytical model for calculation of the ejector optimum geometry for a wide range of operating conditions is developed, using R134a as the working fluid with a rated cooling capacity of 2.5 kW. The maximum values of entrainment... 

    Introducing film cooling uniformity coefficient

    , Article Heat Transfer Engineering ; Volume 39, Issue 2 , 2018 , Pages 180-193 ; 01457632 (ISSN) Javadi, K ; Sharif University of Technology
    Taylor and Francis Ltd  2018
    Abstract
    An optimal performance film cooling implies a high cooling effectiveness along with a wide surface cooling coverage. During the past decades, film cooling effectiveness has been well defined with a specific formula to evaluate the quality of a cooling system. However, despite numerous research on film cooling, there is still no explicit parameter to quantify how well a coolant film is spread over a hot surface. This work introduces a new coefficient namely cooling uniformity coefficient (CUC) to evaluate how well a coolant film is spread over a surface that is being cooled. Four different cases at two blowing ratios of 0.5 and 1.5 are studied. Three cases are ordinary single jets with... 

    Design and analysis of a cooling system for a supersonic exhaust diffuser

    , Article Proceedings of the Institution of Mechanical Engineers, Part G: Journal of Aerospace Engineering ; Volume 233, Issue 14 , 2019 , Pages 5253-5263 ; 09544100 (ISSN) Farahani, M ; Fouladi, N ; Mirbabaei, A. R ; Sharif University of Technology
    SAGE Publications Ltd  2019
    Abstract
    High-altitude test facilities are usually used to evaluate the performance of space mission engines. The supersonic exhaust diffuser, a main part of high-altitude test facility, provides the required test cell vacuum conditions by self-pumping the nozzle exhaust gases to the atmosphere. However, the plume temperature is often much higher than the temperature the diffuser structure is able to withstand, usually above 2500 K. In this study, an efficient cooling system is designed and analyzed to resolve the thermal problem. A water spray cooling technique is preferred among various existing techniques. Here, a new algorithm is developed for a spray cooling system for a supersonic exhaust... 

    Performance evaluation of a modular design ofwind tower withwetted surfaces

    , Article Energies ; Volume 10, Issue 7 , 2017 ; 19961073 (ISSN) Khani, S. M. R ; Bahadori, M. N ; Dehghani Sanij, A ; Nourbakhsh, A ; Sharif University of Technology
    MDPI AG  2017
    Abstract
    Wind towers or wind catchers, as passive cooling systems, can provide natural ventilation in buildings located in hot, arid regions. These natural cooling systems can provide thermal comfort for the building inhabitants throughout the warm months. In this paper, a modular design of a wind tower is introduced. The design, called a modular wind tower with wetted surfaces, was investigated experimentally and analytically. To determine the performance of the wind tower, air temperature, relative humidity (RH) and air velocity were measured at different points. Measurements were carried out when the wind speed was zero. The experimental results were compared with the analytical ones. The results... 

    A comprehensive comparative investigation on solar heating and cooling technologies from a thermo-economic viewpoint—A dynamic simulation

    , Article Energy Science and Engineering ; December , 2020 Jafari Mosleh, H ; Behnam, P ; Abbasi Kamazani, M ; Mohammadi, O ; Kavian, S ; Ahmadi, P ; Rosen, M. A ; Sharif University of Technology
    John Wiley and Sons Ltd  2020
    Abstract
    The yearly thermo-economic performance is dynamically investigated for three solar heating and cooling systems: solar heating and absorption cooling (SHAC), solar heating and ejector cooling (SHEC), and heating and solar vapor compression cooling (HSVC). First, the effects of important design parameters on the thermo-economic performance of the systems to supply the heating and cooling loads of the building are evaluated. The systems are parametrically analyzed with the weather conditions of Tehran, Iran. The results show that the life cycle costs (LCC) of the SHAC and HSVC systems are alike and much lower than those of the SHEC system. The HSVC system exhibits the best performance from... 

    A comprehensive comparative investigation on solar heating and cooling technologies from a thermo-economic viewpoint—A dynamic simulation

    , Article Energy Science and Engineering ; Volume 9, Issue 5 , 2021 , Pages 724-742 ; 20500505 (ISSN) Jafari Mosleh, H ; Behnam, P ; Abbasi Kamazani, M ; Mohammadi, O ; Kavian, S ; Ahmadi, P ; Rosen, M. A ; Sharif University of Technology
    John Wiley and Sons Ltd  2021
    Abstract
    The yearly thermo-economic performance is dynamically investigated for three solar heating and cooling systems: solar heating and absorption cooling (SHAC), solar heating and ejector cooling (SHEC), and heating and solar vapor compression cooling (HSVC). First, the effects of important design parameters on the thermo-economic performance of the systems to supply the heating and cooling loads of the building are evaluated. The systems are parametrically analyzed with the weather conditions of Tehran, Iran. The results show that the life cycle costs (LCC) of the SHAC and HSVC systems are alike and much lower than those of the SHEC system. The HSVC system exhibits the best performance from... 

    The impacts of utilizing nano-encapsulated PCM along with RGO nanosheets in a pulsating heat pipe, a comparative study

    , Article International Journal of Energy Research ; Volume 45, Issue 13 , 2021 , Pages 19481-19499 ; 0363907X (ISSN) Mohammadi, O ; Shafii, M. B ; Rezaee Shirin Abadi, A ; Heydarian, R ; Ahmadi, M. H ; Sharif University of Technology
    John Wiley and Sons Ltd  2021
    Abstract
    Heat pipes are useful devices in heat transfer and particularly, in cooling systems. Given the high demand for cooling systems in various applications, an improvement in the performance of heat pipes has gained much attraction in recent years. In this study, the effects of utilizing working fluids with different thermal properties on the performance of pulsating heat pipes (PHP) are experimentally studied. Hence, nano-encapsulated phase change material (NPCM), reduced graphene oxide nanosheets, and their mixture, as a novel hybrid nanofluid, are prepared and dispersed in water as a working fluid. NPCM at 3 concentrations of 5, 10, and 20 g/L, as well as nanosheets at three concentrations of... 

    Evaluation of a cooling system integrated with different phase change materials and its effect on peak load shaving

    , Article International Journal of Energy Research ; Volume 45, Issue 7 , 2021 , Pages 10425-10449 ; 0363907X (ISSN) Riahi, A ; Kavian, S ; Jafari Mosleh, H ; Shafii, M. B ; Sharif University of Technology
    John Wiley and Sons Ltd  2021
    Abstract
    In this study, a vapor-compression cooling system utilizing different phase change materials (PCMs) has been studied whereby the electricity consumption peak load is shifted. More specifically, the dynamic performance of cooling systems with and without using PCM is evaluated for the hottest day of the year. The proposed system uses the cooling energy to freeze, or “discharge” the PCM during nighttime when the cooling load is minimally needed and uses the stored thermal energy during the peak load hours by melting, or “charging” the PCM. This leads to better performance during peak load hours when higher cooling loads are needed. Different PCMs including oleic acid, SP224A, CL, CaCl2·6H2O... 

    Optimal placement of protective and controlling devices in electric power distribution systems: a MIP model

    , Article IEEE Access ; Volume 7 , 2019 , Pages 122827-122837 ; 21693536 (ISSN) Izadi, M ; Safdarian, A ; Moeini Aghtaie, M ; Lehtonen, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    This paper presents a mathematical model for simultaneous deployment of protective devices (PDs) and controlling devices (CDs) in distribution networks. The PDs include fuses and reclosers and the CDs are remote controlled switches (RCSs) and manual switches (MSs). The model is to minimize equipment costs as well as sustained and momentary interruption costs. It considers the coordination of fuses and reclosers during temporary faults involving fuse saving and fuse blowing schemes. The model is in mixed integer programming (MIP) fashion which can be effectively solved with available solvers. The performance of the proposed model is verified through applying it to Bus 4 of Roy Billinton test... 

    Optimal placement of protective and controlling devices in electric power distribution systems: A MIP Model

    , Article IEEE Access ; Volume 7 , 2019 , Pages 122827-122837 ; 21693536 (ISSN) Izadi, M ; Safdarian, A ; Moeini Aghtaie, M ; Lehtonen, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    This paper presents a mathematical model for simultaneous deployment of protective devices (PDs) and controlling devices (CDs) in distribution networks. The PDs include fuses and reclosers and the CDs are remote controlled switches (RCSs) and manual switches (MSs). The model is to minimize equipment costs as well as sustained and momentary interruption costs. It considers the coordination of fuses and reclosers during temporary faults involving fuse saving and fuse blowing schemes. The model is in mixed integer programming (MIP) fashion which can be effectively solved with available solvers. The performance of the proposed model is verified through applying it to Bus 4 of Roy Billinton test... 

    Iterative machine learning-aided framework bridges between fatigue and creep damages in solder interconnections

    , Article IEEE Transactions on Components, Packaging and Manufacturing Technology ; 2021 ; 21563950 (ISSN) Samavatian, V ; Fotuhi Firuzabad, M ; Samavatian, M ; Dehghanian, P ; Blaabjerg, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2021
    Abstract
    Costly and time-consuming approaches for solder joint lifetime estimation in electronic systems along with the limited availability and incoherency of data challenge the reliability considerations to be among the primary design criteria of electronic devices. In this paper, an iterative machine learning framework is designed to predict the useful lifetime of the solder joint using a set of self-healing data that reinforces the machine learning predictive model with thermal loading specifications, material properties, and geometry of the solder joint. The self-healing dataset is iteratively injected through a correlation-driven neural network to fulfill the data diversity. Outcomes show a... 

    Iterative machine learning-aided framework bridges between fatigue and creep damages in solder interconnections

    , Article IEEE Transactions on Components, Packaging and Manufacturing Technology ; Volume 12, Issue 2 , 2022 , Pages 349-358 ; 21563950 (ISSN) Samavatian, V ; Fotuhi Firuzabad, M ; Samavatian, M ; Dehghanian, P ; Blaabjerg, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2022
    Abstract
    Costly and time-consuming approaches for solder joint lifetime estimation in electronic systems along with the limited availability and incoherency of data challenge the reliability considerations to be among the primary design criteria of electronic devices. In this article, an iterative machine learning framework is designed to predict the useful lifetime of the solder joint using a set of self-healing data that reinforce the machine learning predictive model with thermal loading specifications, material properties, and geometry of the solder joint. The self-healing dataset is iteratively injected through a correlation-driven neural network (CDNN) to fulfill the data diversity. Outcomes... 

    Reliability evaluation of power grids considering integrity attacks against substation protective IEDs

    , Article IEEE Transactions on Industrial Informatics ; Volume 16, Issue 2 , 2020 , Pages 1035-1044 Bahrami, M ; Fotuhi Firuzabad, M ; Farzin, H ; Sharif University of Technology
    IEEE Computer Society  2020
    Abstract
    Secure operation of protective intelligent electronic devices (IEDs) has been recognized as a crucial issue for power grids. By gaining access to substation IEDs, intruders can severely disrupt the operation of protection systems. This paper develops an analytical reliability assessment framework for quantifying the impacts of the hypothesized integrity attacks against protection systems. Petri net models are used to simulate possible intrusion scenarios into substation networks. The cyber network model is constructed from firewall, intrusion prevention system (IPS), and password models, which are three types of defense mechanisms for protecting substation networks. In this paper, two main... 

    Thermal analysis and optimization of a system for water harvesting from humid air using thermoelectric coolers

    , Article Energy Conversion and Management ; Volume 174 , 2018 , Pages 417-429 ; 01968904 (ISSN) Eslami, M ; Tajeddini, F ; Etaati, N ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    Condensation of water vapor available in atmospheric air can be considered as a solution for water scarcity problem. In this paper, a comprehensive thermodynamic analysis of water production from humid air using thermoelectric coolers (TECs) is presented. The system consists of a number of thermoelectric coolers, a fan to supply the required air flow circulation, two cold and hot air channels, heat sinks and solar cells for powering the thermoelectric coolers and fan. Effects of various design parameters are investigated and discussed. The proposed design is optimized to get the maximum effectiveness which is defined as the amount of produced water per unit of energy consumption. Sensitivity... 

    Experimental analysis of a cooling system effect on photovoltaic panels’ efficiency and its preheating water production

    , Article Renewable Energy ; 2018 ; 09601481 (ISSN) Fakouriyan, S ; Saboohi, Y ; Fathi, A ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    This paper addresses a low complexity and high efficient cooling system applicable on photovoltaic (PV) system leading to enhance electrical efficiency and provide preheated water. The developed system consists of a photovoltaic panel, a cooling water system establishing a uniform surface temperature, and a solar water heater. According to the proposed system characteristics, the setup is constructed based on a single mono-crystalline solar panel to absorb more solar radiation intensity and generate more electrical energy per area in compare to a poly-crystalline panel. The preheated water produced by absorbed heat from the photovoltaic is conducted to a solar water heater to satisfy... 

    A year-round dynamic simulation of a solar combined, ejector cooling, heating and power generation system

    , Article Applied Thermal Engineering ; Volume 153 , 2019 , Pages 1-14 ; 13594311 (ISSN) Jafari Mosleh, H ; Hakkaki Fard, A ; DaqiqShirazi, M ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    In this study, a year-round dynamic simulation of a Combined Cooling, Heating and Power generation (CCHP) system has been performed. The proposed system is composed of an ejector cooling system, an Organic Rankine Cycle (ORC), a solar collector field, heat exchangers and hot and cold storage tanks. It is considered that, a portion of the system input energy is provided by a solar collector field and an auxiliary heater supplies the extra required energy. The dynamic simulation of the introduced CCHP system is performed. The developed model is used to evaluate a year-round performance of the system for a residential building located in Tehran. The obtained results indicated that the proposed... 

    A novel hybrid desiccant-based ejector cooling system for energy and carbon saving in hot and humid climates

    , Article International Journal of Refrigeration ; Volume 101 , Volume 101 , 2019 , Pages 196-210 ; 01407007 (ISSN) Heidari, A ; Rostamzadeh, H ; Avami, A ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    Desiccant-based evaporative cooling systems are considered as an energy efficient alternative to conventional vapor compression systems in humid climates. A novel hybrid desiccant-based ejector cooling (hybrid DEC) system is here presented to utilize low grade heat. In order to evaluate the system performance under subtropical humid climates, a dynamic hourly simulation of the system is performed for a typical building in Sydney. The results indicate that the hybrid DEC system is able to provide comfort conditions in subtropical and humid climates. Hybrid DEC system has a significant higher coefficient of performance compared to the conventional vapor compression system resulting to 84%... 

    Experimental analysis of a cooling system effect on photovoltaic panels' efficiency and its preheating water production

    , Article Renewable Energy ; 2019 , Pages 1362-1368 ; 09601481 (ISSN) Fakouriyan, S ; Saboohi, Y ; Fathi, A ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    This paper addresses a low complexity and high efficient cooling system applicable on photovoltaic (PV) system leading to enhance electrical efficiency and provide preheated water. The developed system consists of a photovoltaic panel, a cooling water system establishing a uniform surface temperature, and a solar water heater. According to the proposed system characteristics, the setup is constructed based on a single mono-crystalline solar panel to absorb more solar radiation intensity and generate more electrical energy per area in compare to a poly-crystalline panel. The preheated water produced by absorbed heat from the photovoltaic is conducted to a solar water heater to satisfy... 

    Investigating potential benefits of a salinity gradient solar pond for ejector refrigeration cycle coupled with a thermoelectric generator

    , Article Energy ; Volume 172 , 2019 , Pages 675-690 ; 03605442 (ISSN) Rostamzadeh, H ; Nourani, P ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    Extraction of thermal heat from a salinity-gradient solar pond (SGSP) as a way of accumulating solar energy, stockpiling and taking merit of it for medium and low temperature demands is presented as an interesting topic in recent decades. This reliable supply of heat can be used for low-temperature refrigeration systems to yield cooling load for residential applications. For this purpose, theoretical investigation of ejector refrigeration cycle (ERC) driven by a SGSP is carried out to produce cooling output. Also, thermoelectric generator (TEG) is used as a potential device replacing condenser of the ERC for the sake of bolstering performance of the fundamental system by producing power,... 

    An innovative solar assisted desiccant-based evaporative cooling system for co-production of water and cooling in hot and humid climates

    , Article Energy Conversion and Management ; Volume 185 , 2019 , Pages 396-409 ; 01968904 (ISSN) Heidari, A ; Roshandel, R ; Vakiloroaya, V ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    Although evaporative coolers consume much lower electricity than the vapor compression systems, they are not applicable in humid climates. Combination of desiccant wheels and evaporative coolers, known as desiccant-based evaporative cooling systems, allows evaporative coolers to be used in humid climates, which provide significant energy and environmental advantages with respect to vapor compression systems. However, one of the main disadvantages of evaporative cooling is the high water. Regarding the global water crisis, a cooling system which saves both water and energy will be an attractive alternative to the current cooling systems. To this aim, this paper presents a novel...