    Numerical simulation of a microfluidic system for regular glucose measurement

    , Article 26th National and 4th International Iranian Conference on Biomedical Engineering, ICBME 2019, 27 November 2019 through 28 November 2019 ; 2019 , Pages 60-65 ; 9781728156637 (ISBN) Najmi, A ; Saidi, M. S ; Shahrokhian, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    The aim of this research is to design an implantable integrated microfluidic system in order to regularly measure the glucose level in the human body, nonenzymatically, using the microdialysis method. The main compartments of this system are a micropump, array of hollow microneedles and an electrochemical sensor. At the base of the microneedles, there are located semipermeable membranes, that when the pumped dialysis fluid passes over them, the glucose of the interstitial fluid diffuses into the dialysis fluid and then, in the sensor section, it is measured nonenzymatically using the amperometry method. Both the arrangement of the miconeedles and the amount of the dialysis fluid flow are... 

    Explicit finite element modeling of wear within the patellofemoral joint in total knee replacement

    , Article 26th National and 4th International Iranian Conference on Biomedical Engineering, ICBME 2019, 27 November 2019 through 28 November 2019 ; 2019 , Pages 208-212 ; 9781728156637 (ISBN) Bahadoran, M ; Dorri Nokoorani, Y ; Barati, K ; Farahmand, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Total knee replacement (TKR) surgery is one of the most successful and cost-effective procedures for treating knee injuries performed in orthopedics. However, the knee replacement revision surgery will probably be required after some years. Wear at the contact area between femoral metal component and the polyethylene inserts in TKR is recognized as one of the foremost causes of prosthesis failure and necessity of revision surgery. In the present study, focusing on the patellofemoral joint (PFJ), the wear at the contact area between the patellar and femoral components has been simulated employing the explicit finite element modeling. In this regard, common types of patellar component surface... 

    Design and fabrication of an ubiquitous, low-cost, and wearable respiratory bio-sensor using ionic soft materials

    , Article 26th National and 4th International Iranian Conference on Biomedical Engineering, ICBME 2019, 27 November 2019 through 28 November 2019 ; 2019 , Pages 55-59 ; 9781728156637 (ISBN) Annabestani, M ; Mirzaei, I ; Esmaeili Dokht, P ; Fardmanesh, M
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    The respiratory system is a vital organ system which makes breathing and gas exchange possible for human's body. The loss of functionality in this system is due to either genetical problems or environmental issues like pollution or toxic gases which in many cases is inevitable. These circumstances may cause different respiratory diseases which may not be curable presently but their side effects can be partly controlled by careful and timely analysis improving the quality of patient's life. So, an appropriate device for conducting different analysis can be effective for people who suffer from respiratory diseases such as chronic obstructive pulmonary disease (COPD), asthma, occupational lung... 

    Effects of different corneal ring segments with identical total arc length on keratoconic eyes: a finite element study

    , Article 26th National and 4th International Iranian Conference on Biomedical Engineering, ICBME 2019, 27 November 2019 through 28 November 2019 ; 2019 , Pages 1-3 ; 9781728156637 (ISBN) Katoozian, H. R ; Sajadi, S. B ; Khanlari, M ; Gholami, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Keratoconus (KC) is a progressive corneal disease. It is mostly characterized by corneal thinning and irregular steepening as well as formation of cone-shaped regions on the cornea. Amongst treatment modalities, implantation of Intrastromal Corneal Ring Segments (ICRSs) could decrease corneal surface irregularities. However, controversy exists over the selection of proper ICRSs. Here, the aim was to compare the effects of two sets of ICRSs. The ICRSs were identical both in cross-section and total arc length. The results showed that under normal physiological range of intraocular pressures (IOPs), the two selected ICRSs caused slightly different deformations in the same in-silico keratoconic... 

    Effect of oxidizing atmosphere on the surface of titanium dental implant material

    , Article Journal of Bionic Engineering ; Volume 16, Issue 6 , 2019 , Pages 1052-1060 ; 16726529 (ISSN) Khodaei, M ; Alizadeh, A ; Madaah Hosseini, H. R ; Sharif University of Technology
    Springer  2019
    Abstract
    Direct oxidation is a simple and effective method for titanium surface treatment. In this research, a titanium sample was directly oxidized at the high temperature in two different atmospheres, air and pure oxygen, to obtain better atmosphere for titanium surface treatment. The results of the Raman spectroscopy indicated that in both atmospheres, the rutile bioactive phase (TiO2) has been formed on the titanium surface. The results of X-ray diffraction (XRD) also revealed that the surface of oxygen-treated sample was composed of the rutile phase and titanium monoxide (TiO), while at the surface of the air-treated sample, the rutile phase and titanium dioxide had been formed. Further, the... 

    The effects of thymus plant extracts on single breast cancer cell morphology in the microfluidic channel

    , Article 2018 IEEE EMBS Conference on Biomedical Engineering and Sciences, IECBES 2018, 3 December 2018 through 6 December 2018 ; 2019 , Pages 647-651 ; 9781538624715 (ISBN) Ahmad, M. R ; Mansor, M. A ; Alsadat Rad, M ; Soo-Beng Khoo, A ; Ahmad, M ; Marzuki, M ; Physiological Measurement; Sarawak Convention Bureau ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Microfluidics based systems could be useful for drug discovery as they allow for miniaturization and could potentially be run as multiple parallel cell based assays. Such miniaturization allows assays at single cell level and reduces the amount of test material needed, which, in the case of natural product extracts, simplifies the preparation. Thyme species extracts have been reported to show some promising anti-cancer effects. In the present work, we used a microfluidics based system to study the effects of Thymus kotschyanusm Boiss plant extract on two human breast cancer cells lines which are MDA-MB-231 and MCF-7. For better understanding a single cancer cell death mechanism and a flow... 

    Primary stenosis progression versus secondary stenosis formation in the left coronary bifurcation: a mechanical point of view

    , Article Biocybernetics and Biomedical Engineering ; Volume 39, Issue 1 , 2019 , Pages 188-198 ; 02085216 (ISSN) Jahromi, R ; Pakravan, H. A ; Saidi, M. S ; Firoozabadi, B ; Sharif University of Technology
    Elsevier Sp. z o.o  2019
    Abstract
    Biomechanical forces and hemodynamic factors influence the blood flow and the endothelial cells (ECs) morphology. These factors behave differently beyond the coronary artery stenosis. In the present study, unsteady blood flow in the left coronary artery (LCA) and its atherosclerotic bifurcating vessels, left anterior descending (LAD) and left circumflex (LCX) arteries, were numerically simulated to investigate the risk of plaque length development and secondary plaque formation in the post-stenotic areas. Using fluid–structure interaction (FSI) model, compliance of arterial wall and vessel curvature variations due to cardiac motion were considered. The arteries included plaques at the... 

    Primary stenosis progression versus secondary stenosis formation in the left coronary bifurcation: a mechanical point of view

    , Article Biocybernetics and Biomedical Engineering ; Volume 39, Issue 1 , 2019 , Pages 188-198 ; 02085216 (ISSN) Jahromi, R ; Pakravan, H. A ; Saidi, M. S ; Firoozabadi, B ; Sharif University of Technology
    Elsevier Sp. z o.o  2019
    Abstract
    Biomechanical forces and hemodynamic factors influence the blood flow and the endothelial cells (ECs) morphology. These factors behave differently beyond the coronary artery stenosis. In the present study, unsteady blood flow in the left coronary artery (LCA) and its atherosclerotic bifurcating vessels, left anterior descending (LAD) and left circumflex (LCX) arteries, were numerically simulated to investigate the risk of plaque length development and secondary plaque formation in the post-stenotic areas. Using fluid–structure interaction (FSI) model, compliance of arterial wall and vessel curvature variations due to cardiac motion were considered. The arteries included plaques at the... 

    Joint, partially-joint, and individual independent component analysis in multi-subject fMRI data

    , Article IEEE Transactions on Biomedical Engineering ; Volume 67, Issue 7 , 2020 , Pages 1969-1981 Pakravan, M ; Shamsollahi, M. B ; Sharif University of Technology
    IEEE Computer Society  2020
    Abstract
    Objective: Joint analysis of multi-subject brain imaging datasets has wide applications in biomedical engineering. In these datasets, some sources belong to all subjects (joint), a subset of subjects (partially-joint), or a single subject (individual). In this paper, this source model is referred to as joint/partially-joint/individual multiple datasets unidimensional (JpJI-MDU), and accordingly, a source extraction method is developed. Method: We present a deflation-based algorithm utilizing higher order cumulants to analyze the JpJI-MDU source model. The algorithm maximizes a cost function which leads to an eigenvalue problem solved with thin-SVD (singular value decomposition)... 

    Efficient health monitoring of buildings using failure modes and effects analysis case study: Air handling unit system

    , Article Journal of Building Engineering ; Volume 29 , 2020 Parhizkar, T ; Aramoun, F ; Saboohi, Y ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    System health management based on condition monitoring is of great value and significance for improving system performance and reliability. As more data from condition monitoring is obtained, the efficiency of system health monitoring improves. However, increasing the amount of data by installing new sensors on system components is restricted by a variety of factors such as budget, weight and space allowance. Therefore, sensor selection in the most optimal manner in order to achieve maximum valuable information from system is an important issue. In this study, a novel concept is introduced that can be used in sensor combination optimization problems. This concept employs failure modes and... 

    Controlling the depth of anesthesia by using extended DMC

    , Article 2008 Cairo International Biomedical Engineering Conference, CIBEC 2008, Cairo, 18 December 2008 through 20 December 2008 ; 2008 ; 9781424426959 (ISBN) Bamdadian, A ; Towhidkhah, F ; Marami, B ; Sharif University of Technology
    2008
    Abstract
    Monitoring and controlling the depth of anesthesia is really important, since over dosing and under dosing can be dangerous for the patients. Pharmacokinetic-Pharmacodynamic models vastly used for describing the relationship between input anesthetic agents and output patient endpoint variables. As there is a large variety between the patients so for controlling the depth of anesthesia we need a controller which should be robust enough and also because the anesthesia process is nonlinear and contains time delay, among them all the proposed methods for controlling the depth of anesthesia, model predictive controllers (MPCs) are good choices. Extended dynamic matrix control (EDMC) can be... 

    Flow regime mapping for a two-phase system of aqueous alginate and water droplets in T-junction geometry

    , Article Physics of Fluids ; Volume 33, Issue 7 , 2021 ; 10706631 (ISSN) Mehraji, S ; Saadatmand, M ; Sharif University of Technology
    American Institute of Physics Inc  2021
    Abstract
    Microfluidic systems are an interesting topic for investigation due to their wide-spreading applications. Nowadays, polymeric solutions are used mainly for the generation of microparticles in biomedical engineering, food, and pharmaceutical industries. Droplet-based microfluidic devices have proposed an extensive interest in many applications such as chemical/biological/nanomaterial preparation to understand deeply the droplet size and formation in microchannels. However, numerous experimental and numerical studies have been done for oil-water combination, polymeric solutions behavior in the presence of oil has not been investigated widely. Therefore, it is important to understand the... 

    An adaptive feedback bit allocation method for wireless systems with transmit diversity

    , Article 2005 1st International Conference on Computers, Communications and Signal Processing with Special Track on Biomedical Engineering, CCSP 2005, Kuala Lumpur, 14 November 2005 through 16 November 2005 ; 2005 , Pages 181-184 ; 1424400112 (ISBN); 9781424400119 (ISBN) Babadi, B ; Shariatpanahi, P ; Hossein Khalaj, B ; Sharif University of Technology
    2005
    Abstract
    Using multiple antenna transmitters and/or receivers is becoming a common method for improving spectral efficiency of wireless channels. The physical layer of the next generation of WLAN systems (802.11n) is based on a Multiple Input Multiple Output (MIMO) system which seems to be an efficient solution for defects which could occur in wireless channels. In this paper, we investigate an adaptive bit allocation method to feed the quantized channel state data back to the transmitting antennas, depending on the channel condition in a Multiple Input Single Output (MISO) scheme. We have proposed an adaptive bit allocation scheme with a significant performance improvement over the fixed bit... 

    Development of a genetic algorithm based biomechanical simulation of sagittal lifting tasks

    , Article Biomedical Engineering - Applications, Basis and Communications ; Volume 17, Issue 1 , 2005 , Pages 12-18 ; 10162372 (ISSN) Gündoǧdu, Ö ; Anderson, K. S ; Parnianpour, M ; Sharif University of Technology
    Institute of Biomedical Engineering  2005
    Abstract
    Fibrin sealant and platelet gels are human blood-derived, biodegradable, non toxic, surgical products obtained by mixing a fibrinogen concentrate or a platelet rich plasma with thrombin, respectively. Fibrin sealant is now a well known surgical tool increasingly used to stop or control bleeding, or to provide air and fluid tightness in many surgical situations. Platelet gels are newly developed preparations that are of specific interest because they contain numerous physiological growth factors and cytikines that are released upon the activation of blood platelets by thrombin. These growth factors, including PDGF, TGF-β1, BMP, and VEGF have been shown to stimulate cell growth and... 

    Biomedical engineering of polysaccharide-based tissue adhesives: Recent advances and future direction

    , Article Carbohydrate Polymers ; Volume 295 , 2022 ; 01448617 (ISSN) Shokrani, H ; Shokrani, A ; Seidi, F ; Munir, M. T ; Rabiee, N ; Fatahi, Y ; Kucinska Lipka, J ; Saeb, M. R ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Tissue adhesives have been widely used for preventing wound leaks, sever bleeding, as well as for enhancing drug delivery and biosensing. However, only a few among suggested platforms cover the circumstances required for high-adhesion strength and biocompatibility, without toxicity. Antibacterial properties, controllable degradation, encapsulation capacity, detectability by image-guided procedures and affordable price are also centered to on-demand tissue adhesives. Herein we overview the history of tissue adhesives, different types of polysaccharide-based tissue adhesives, their mechanism of gluing, and different applications of polysaccharide-based tissue adhesives. We also highlight the... 

    Processing and microstructure of Ti-Cu binary alloys: A comprehensive review

    , Article Progress in Materials Science ; Volume 127 , 2022 ; 00796425 (ISSN) Akbarpour, M.R ; Mirabad, H. M ; Hemmati, A ; Kim, H. S ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Titanium alloys are widely used in various areas, particularly in medical and dental industries, due to their remarkable properties. Still, the optimum cutting conditions for titanium alloys are under consideration. Ti alloyed with Cu has been reported to provide unique properties such as good mechanical performance, good biocompatibility, acceptable corrosion resistance, and relatively lower melting point. The properties of Ti-Cu alloys mentioned above are sensitive to microstructure. They are highly dependent on microstructural characteristics such as the formation, growth, and morphological features of intermetallics and precipitates, dependent on the amount of Cu and the manufacturing... 

    Fabrication and characterization of conductive chitosan/gelatin-based scaffolds for nerve tissue engineering

    , Article International Journal of Biological Macromolecules ; Volume 74 , 2015 , Pages 360-366 ; 01418130 (ISSN) Baniasadi, H ; Ramazani S. A., A ; Mashayekhan, S ; Sharif University of Technology
    Abstract
    This paper reports on the development of conductive porous scaffolds by incorporating conductive polyaniline/graphene (PAG) nanoparticles into a chitosan/gelatin matrix for its potential application in peripheral nerve regeneration. The effect of PAG content on the various properties of the scaffold is investigated and the results showed that the electrical conductivity and mechanical properties increased proportional to the increase in the PAG loading, while the porosity, swelling ratio and in vitro biodegradability decreased. In addition, the biocompatibility was evaluated by assessing the adhesion and proliferation of Schwann cells on the prepared scaffolds using SEM and MTT assay,... 

    The effects of trochlear groove geometry on patellofemoral joint stability - A computer model study

    , Article Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine ; Volume 222, Issue 1 , 2008 , Pages 75-88 ; 09544119 (ISSN) Jafari, A ; Farahmand, F ; Meghdari, A ; Sharif University of Technology
    2008
    Abstract
    The effect of the variation in the femoral groove geometry on patellofemoral joint stability was studied using a two dimensional transverse plane model with deformable articular surfaces. The femoral and patellar bony structures were modelled as rigid bodies with their profiles expressed by splines. The articular cartilage was discretized into compression springs, distributed along the femoral and patellar profiles, based on the rigid-body spring model. The medial and lateral retinacula were modelled as linear tensile springs, and the quadriceps muscles and patellar tendon as strings with known tension. The anatomical data were obtained from the transverse plane magnetic resonance images of... 

    Assessment of preprocessing on classifiers used in the P300 speller paradigm

    , Article 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06, New York, NY, 30 August 2006 through 3 September 2006 ; 2006 , Pages 1319-1322 ; 05891019 (ISSN); 1424400325 (ISBN); 9781424400324 (ISBN) Mirghasemi, H ; Shamsollahi, M. B ; Fazel Rezai, R ; Sharif University of Technology
    2006
    Abstract
    Artifact removal is an essential part in electroencephalogram (EEG) recording and the raw EEG signals require preprocessing before feature extraction. In this work, we implemented three filtering methods and demonstrated their effects on the performance of different classifiers. Bandpass digital filtering, median filtering and facet method are three preprocessing approaches investigated in this paper. We used data set lib from the BCI competition 2003 for training and testing phase. Our accuracy varied between 80% and 96%. In our work, we demonstrated that the problems of choosing the classifier and preprocessing methods are not independent of each other. Two of our approaches could achieve...