Loading...
Search for: microfluidics
0.015 seconds
Total 321 records

    A continuous flow microfluidic device based on contactless dielectrophoresis for bioparticles enrichment

    , Article Electrophoresis ; Volume 39, Issue 3 , 2018 , Pages 445-455 ; 01730835 (ISSN) Rahmani, A ; Mohammadi, A. A ; Kalhor, H. R ; Sharif University of Technology
    Wiley-VCH Verlag  2018
    Abstract
    In recent years, applications of dielectrophoresis-based platforms have been recognized as effective and dependable approach to separate cells and bioparticles, suspended in different carrier fluids, based on particle size and electrical properties. In this study, a microfluidic device was fabricated by an unprecedented electrode pattern, and several experiments were performed to enrich samples including either of yeast, Escherichia coli, or latex particles. A chemical deposition-based method was employed for fabrication of microelectrodes, inducing nonuniform electric field required for dielectrophoresis-based separation. One major advantage of our employed method is low fabrication cost,... 

    Pure axial flow of viscoelastic fluids in rectangular microchannels under combined effects of electro-osmosis and hydrodynamics

    , Article Theoretical and Computational Fluid Dynamics ; Volume 32, Issue 1 , 2018 ; 09354964 (ISSN) Reshadi, M ; Saidi, M. H ; Ebrahimi, A ; Sharif University of Technology
    Springer New York LLC  2018
    Abstract
    This paper presents an analysis of the combined electro-osmotic and pressure-driven axial flows of viscoelastic fluids in a rectangular microchannel with arbitrary aspect ratios. The rheological behavior of the fluid is described by the complete form of Phan-Thien–Tanner (PTT) model with the Gordon–Schowalter convected derivative which covers the upper convected Maxwell, Johnson–Segalman and FENE-P models. Our numerical simulation is based on the computation of 2D Poisson–Boltzmann, Cauchy momentum and PTT constitutive equations. The solution of these governing nonlinear coupled set of equations is obtained by using the second-order central finite difference method in a non-uniform grid... 

    A novel magnetic microfluidic platform for on-chip separation of 3 types of silica coated magnetic nanoparticles (Fe3O4@SiO2)

    , Article Sensors and Actuators, A: Physical ; Volume 270 , 2018 , Pages 223-230 ; 09244247 (ISSN) Kashanian, F ; Kokkinis, G ; Bernardi, J ; Zand, M. R ; Shamloo, A ; Giouroudi, I ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    This paper presents a compact and cost effective method for on-chip separation of silica-coated magnetic nanoparticles (SMNPs) with different hydrodynamic size. Three types of SMNPs (Fe3O4@SiO2) with the same magnetic core but with different thickness of silica shells were successfully separated using the developed microfluidic platform. The innovative aspect of the presented separation method is that the induced velocity on the three different types of SMNPs while imposed to the same magnetic field gradient in a static fluid is inversely proportional to their overall, non-magnetic volume. This is due to the enhanced Stokes’ drag force exerted on the nanoparticles (NPs) resulting from their... 

    A microfabricated platform for the study of chondrogenesis under different compressive loads

    , Article Journal of the Mechanical Behavior of Biomedical Materials ; Volume 78 , 2018 , Pages 404-413 ; 17516161 (ISSN) Kowsari Esfahan, R ; Jahanbakhsh, A ; Saidi, M. S ; Bonakdar, S ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    Microfluidic devices are beneficial in miniaturizing and multiplexing various cellular assays in a single platform. Chondrogenesis is known to pertain to chemical, topographical, and mechanical cues in the microenvironment. Mechanical cues themselves have numerous parameters such as strain magnitude, frequency, and stimulation time. Effects of different strain magnitudes on the chondrogenic differentiation of adult stem cells have not been explored thoroughly. Here, a new multilayer microdevice is presented for the unidirectional compressive stimulation of cells in a three-dimensional cell culture. Numerical simulations were performed to evaluate and optimize the design. Results showed a... 

    Controlling differentiation of stem cells for developing personalized organ-on-chip platforms

    , Article Advanced Healthcare Materials ; Volume 7, Issue 2 , 2018 ; 21922640 (ISSN) Geraili, A ; Jafari, P ; Sheikh Hassani, M ; Heidary Araghi, B ; Mohammadi, M. H ; Ghafari, A. M ; Hassanpour Tamrin, S ; Pezeshgi Modarres, H ; Rezaei Kolahchi, A ; Ahadian, S ; Sanati Nezhad, A ; Sharif University of Technology
    Wiley-VCH Verlag  2018
    Abstract
    Organ-on-chip (OOC) platforms have attracted attentions of pharmaceutical companies as powerful tools for screening of existing drugs and development of new drug candidates. OOCs have primarily used human cell lines or primary cells to develop biomimetic tissue models. However, the ability of human stem cells in unlimited self-renewal and differentiation into multiple lineages has made them attractive for OOCs. The microfluidic technology has enabled precise control of stem cell differentiation using soluble factors, biophysical cues, and electromagnetic signals. This study discusses different tissue- and organ-on-chip platforms (i.e., skin, brain, blood–brain barrier, bone marrow, heart,... 

    Spiral microchannel with stair-like cross section for size-based particle separation

    , Article Microfluidics and Nanofluidics ; Volume 21, Issue 7 , 2017 ; 16134982 (ISSN) Ghadami, S ; Kowsari Esfahan, R ; Saidi, M. S ; Firoozbakhsh, K ; Sharif University of Technology
    Springer Verlag  2017
    Abstract
    Particle separation has a variety of applications in biology, chemistry and industry. Among them, circulating tumor cells (CTCs) separation has drawn significant attention to itself due to its high impact on both cancer diagnosis and therapeutics. In recent years, there has been growing interest in using inertial microfluidics to separate micro/nano particles based on their sizes. This technique offers label-free, high-throughput and efficient separation and can be easily fabricated. However, further improvements are needed for potential clinical applications. In this study, a novel inertial separation technique using spiral microchannel having stair-like cross section is introduced. The... 

    Analyzing mixing quality in a curved centrifugal micromixer through numerical simulation

    , Article Chemical Engineering and Processing: Process Intensification ; Volume 116 , 2017 , Pages 9-16 ; 02552701 (ISSN) Shamloo, A ; Vatankhah, P ; Akbari, A ; Sharif University of Technology
    Elsevier B.V  2017
    Abstract
    The Lab On a CD (LOCD), also known as Centrifugal Microfluidics, has evolved into a sophisticated platform for performing biomedical assays due to its marvelous miniaturization and accurate simulation of biological reactions. Among the numerous applications of the LOCD is fluid mixing. In this paper a centrifugal, serpentine micromixer is simulated and reformed toward better mixing performance. The micromixer was chosen to be curved as a curved design was found to be thrice as functional and compact as a rectilinear design, mixing-wise. The two angular velocity and opening radius parameters were originally hypothesized to affect mixing performance. Effect of angular velocity was studied over... 

    Halogen-lithium exchange reaction using an integrated glass microfluidic device: an optimized synthetic approach

    , Article Organic Process Research and Development ; Volume 21, Issue 3 , 2017 , Pages 292-303 ; 10836160 (ISSN) Zeibi Shirejini, S ; Mohammadi, A ; Sharif University of Technology
    American Chemical Society  2017
    Abstract
    A telescoped approach was developed for the efficient synthesis of methoxybenzene through the generation of an unstable intermediate reagent, based on the Br-Li exchange reaction of p-bromoanisole and n-BuLi, followed by its reaction with water. In the first stage, p-methoxyphenyllithium was synthesized and consumed immediately in the second stage. For this purpose, an integrated glass microfluidic device was fabricated using laser ablation followed by the thermal fusion bonding method. The impact of various parameters, including solvent, reaction time, molar ratio, concentration of reagents, and flow rates were investigated to achieve the highest yield of the desired product, leading to an... 

    Dynamical analysis of microfluidic microbial electrolysis cell via integrated experimental investigation and mathematical modeling

    , Article Electrochimica Acta ; Volume 227 , 2017 , Pages 317-329 ; 00134686 (ISSN) Mardanpour, M. M ; Yaghmaei, S ; Sharif University of Technology
    Elsevier Ltd  2017
    Abstract
    The present study deals with the feasibility of a microfluidic microbial electrolysis cell (MEC) as an efficient biohydrogen generator for medical usage for the first time. The evaluation of nickel in microfluidic MEC as an alternative for conventional electrodes indicates successful performance in the improvement of bioenergy production. The maximum biohydrogen production rate and produced power density of 2.2 μW cm−2 and 1.4 μl H2 μl substrate−1 day−1 were obtained, respectively. It is considered a promising technology for medical usage due to the following factors: significant biohydrogen generation, low consumption of expensive materials, simple construction, and utilization of human... 

    Modeling of microfluidic microbial fuel cells using quantitative bacterial transport parameters

    , Article Journal of Power Sources ; Volume 342 , 2017 , Pages 1017-1031 ; 03787753 (ISSN) Mardanpour, M. M ; Yaghmaei, S ; Kalantar, M ; Sharif University of Technology
    Elsevier B.V  2017
    Abstract
    The objective of present study is to analyze the dynamic modeling of bioelectrochemical processes and improvement of the performance of previous models using quantitative data of bacterial transport parameters. The main deficiency of previous MFC models concerning spatial distribution of biocatalysts is an assumption of initial distribution of attached/suspended bacteria on electrode or in anolyte bulk which is the foundation for biofilm formation. In order to modify this imperfection, the quantification of chemotactic motility to understand the mechanisms of the suspended microorganisms’ distribution in anolyte and/or their attachment to anode surface to extend the biofilm is implemented... 

    Electrospun polyethersolfone nanofibrous membrane as novel platform for protein immobilization in microfluidic systems

    , Article Journal of Biomedical Materials Research - Part B Applied Biomaterials ; 2017 ; 15524973 (ISSN) Mahmoudifard, M ; Vossoughi, M ; Soudi, S ; Soleimani, M ; Sharif University of Technology
    John Wiley and Sons Inc  2017
    Abstract
    In the present study, the feasibility of electrospun polyethersolfone (PES) nanofibrous membrane as the solid substrate for microfluidic based immunoassays to enhance the density of immobilized antibody on the surface of membrane was assessed. Conversely, the efficacy of antibody immobilization was compared by two different strategies as 1-Ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC)/N-Hydroxysuccinimide (NHS) coupling chemistry and hydrophobic interaction. Compared to conventional immunoassays carried out in plates or gels, microfluidic based immunoassays grant a lot of advantages such as a consumption of little samples and reagents, shorter analysis time, and higher efficiency.... 

    Toward a comprehensive microextraction/determination unit: A chip silicon rubber polyaniline-based system and its direct coupling with gas chromatography and mass spectrometry

    , Article Journal of Separation Science ; Volume 39, Issue 21 , 2016 , Pages 4227-4233 ; 16159306 (ISSN) Bagheri, H ; Allahdadlalouni, M ; Zamani, C ; Sharif University of Technology
    Wiley-VCH Verlag  2016
    Abstract
    An inexpensive silicon rubber-based chip was constructed by fabricating a triangle-shaped microcanal with a 135 μm width and 234 μm depth by laser ablation technique. The fabricated groove was sealed by a thin glass cover while two pieces of stainless-steel tubing were connected to each side of the canal. Then, a thin polyaniline film was synthesized on the walls of the canal by chemical oxidation using a syringe pump to deliver the relevant reagents. The microfluidic system was eventually connected to a gas chromatography-mass spectrometry. To evaluate the capability of the constructed microfluidic system, it was implemented to the analysis of submilliliter volumes of environmental samples... 

    Designing and modeling a centrifugal microfluidic device to separate target blood cells

    , Article Journal of Micromechanics and Microengineering ; Volume 26, Issue 3 , 2016 ; 09601317 (ISSN) Shamloo, A ; Selahi, Aa ; Madadelahi, M ; Sharif University of Technology
    Institute of Physics Publishing  2016
    Abstract
    The objective of this study is to design a novel and efficient portable lab-on-a-CD (LOCD) microfluidic device for separation of specific cells (target cells) using magnetic beads. In this study the results are shown for neutrophils as target cells. However, other kinds of target cells can be separated in a similar approach. The designed microfluidics can be utilized as a point of care system for neutrophil detection. This microfluidic system employs centrifugal and magnetic forces for separation. After model validation by the experimental data in the literature (that may be used as a design tool for developing centrifugo-magnetophoretic devices), two models are presented for separation of... 

    Microfluidic systems for stem cell-based neural tissue engineering

    , Article Lab on a Chip - Miniaturisation for Chemistry and Biology ; Volume 16, Issue 14 , 2016 , Pages 2551-2571 ; 14730197 (ISSN) Karimi, M ; Bahrami, S ; Mirshekari, H ; Moosavi Basri, S. M ; Bakhshian Nik, A ; Aref, A. R ; Akbari, M ; Hamblin, M. R ; Sharif University of Technology
    Royal Society of Chemistry  2016
    Abstract
    Neural tissue engineering aims at developing novel approaches for the treatment of diseases of the nervous system, by providing a permissive environment for the growth and differentiation of neural cells. Three-dimensional (3D) cell culture systems provide a closer biomimetic environment, and promote better cell differentiation and improved cell function, than could be achieved by conventional two-dimensional (2D) culture systems. With the recent advances in the discovery and introduction of different types of stem cells for tissue engineering, microfluidic platforms have provided an improved microenvironment for the 3D-culture of stem cells. Microfluidic systems can provide more precise... 

    High throughput blood plasma separation using a passive PMMA microfluidic device

    , Article Microsystem Technologies ; Volume 22, Issue 10 , 2016 , Pages 2447-2454 ; 09467076 (ISSN) Shamsi, A ; Shamloo, A ; Mohammadaliha, N ; Hajghassem, H ; Fallah Mehrabadi, J ; Bazzaz, M ; Sharif University of Technology
    Springer Verlag  2016
    Abstract
    Since plasma is rich in many biomarkers used in clinical diagnostic experiments, microscale blood plasma separation is a primitive step in most of microfluidic analytical chips. In this paper, a passive microfluidic device for on-chip blood plasma separation based on Zweifach–Fung effect and plasma skimming was designed and fabricated by hot embossing of microchannels on a PMMA substrate and thermal bonding process. Human blood was diluted in various times and injected into the device. The main novelty of the proposed microfluidic device is the design of diffuser-shaped daughter channels. Our results demonstrated that this design exerted a considerable positive influence on the separation... 

    Electrokinetic and aspect ratio effects on secondary flow of viscoelastic fluids in rectangular microchannels

    , Article Microfluidics and Nanofluidics ; Volume 20, Issue 8 , 2016 ; 16134982 (ISSN) Reshadi, M ; Saidi, M. H ; Firoozabadi, B ; Saidi, M. S ; Sharif University of Technology
    Springer Verlag  2016
    Abstract
    The secondary flow of PTT fluids in rectangular cross-sectional plane of microchannels under combined effects of electroosmotic and pressure driving forces is the subject of the present study. Employing second-order central finite difference method in a very refined grid network, we investigate the effect of electrokinetic and geometric parameters on the pattern, strength and the average of the secondary flow. In this regard, we try to illustrate the deformations of recirculating vortices due to change in the dimensionless Debye–Hückel and zeta potential parameters as well as channel aspect ratio. We demonstrate that, in the presence of thick electric double layers, significant alteration... 

    Organ-tumor-on-a-chip for chemosensitivity assay: A critical review

    , Article Micromachines ; Volume 7, Issue 8 , 2016 ; 2072666X (ISSN) Kashaninejad, N ; Nikmaneshi, M. R ; Moghadas, H ; Kiyoumarsi Oskouei, A ; Rismanian, M ; Barisam, M ; Saidi, M. S ; Firoozabadi, B ; Sharif University of Technology
    MDPI AG  2016
    Abstract
    With a mortality rate over 580,000 per year, cancer is still one of the leading causes of death worldwide. However, the emerging field of microfluidics can potentially shed light on this puzzling disease. Unique characteristics of microfluidic chips (also known as micro-total analysis system) make them excellent candidates for biological applications. The ex vivo approach of tumor-on-a-chip is becoming an indispensable part of personalized medicine and can replace in vivo animal testing as well as conventional in vitro methods. In tumor-on-a-chip, the complex three-dimensional (3D) nature of malignant tumor is co-cultured on a microfluidic chip and high throughput screening tools to evaluate... 

    Numerical simulation of centrifugal serpentine micromixers and analyzing mixing quality parameters

    , Article Chemical Engineering and Processing: Process Intensification ; Volume 104 , 2016 , Pages 243-252 ; 02552701 (ISSN) Shamloo, A ; Madadelahi, M ; Akbari, A ; Sharif University of Technology
    Elsevier, B.V  2016
    Abstract
    Centrifugal microfluidics or the Lab on a CD (LOCD) has developed vast applications in biomedical researches and analyses. Fluid mixing is an application of the LOCD. In this paper, multiple centrifugal micromixers were simulated. Various parameters were originally presumed to have an effect on mixing performance. These parameters include inlet angle, angular velocity, cross-sectional profile, perpendicular length ratio and the number of channels in series. They were each analyzed through simulations. It was gathered that the inlet angle does not significantly affect the mixing quality. Increasing angular velocity steadily increases mixing quality for all geometries. The vertical triangular... 

    Characterization of a microfluidic microbial fuel cell as a power generator based on a nickel electrode

    , Article Biosensors and Bioelectronics ; Volume 79 , 2016 , Pages 327-333 ; 09565663 (ISSN) Mardanpour, M. M ; Yaghmaei, S ; Sharif University of Technology
    Elsevier Ltd  2016
    Abstract
    This study reports the fabrication of a microfluidic microbial fuel cell (MFC) using nickel as a novel alternative for conventional electrodes and a non-phatogenic strain of Escherichia coli as the biocatalyst. The feasibility of a microfluidic MFC as an efficient power generator for production of bioelectricity from glucose and urea as organic substrates in human blood and urine for implantable medical devices (IMDs) was investigated. A maximum open circuit potential of 459mV was achieved for the batch-fed microfluidic MFC. During continuous mode operation, a maximum power density of 104Wm-3 was obtained with nutrient broth. For the glucose-fed microfluidic MFC, the maximum power density of... 

    Numerical optimization and inverse study of a microfluidic device for blood plasma separation

    , Article European Journal of Mechanics, B/Fluids ; Volume 57 , 2016 , Pages 31-39 ; 09977546 (ISSN) Shamloo, A ; Vatankhah, P ; Bijarchi, M. A ; Sharif University of Technology
    Elsevier Ltd  2016
    Abstract
    In this paper, a passive microfluidic device for continuous real time blood plasma separation has been studied and optimized. A numerical model is used to solve both the fluid flow and the particles confined within it. Red blood cells are considered as particles with diameter of 7μm. A parametric study is performed in order to characterize the effect of different parameters on separation and purity efficiency. In this study, four different variables were introduced to design the microfluidic device for blood plasma separation including: the angle between the daughter channels and the main channel, the widths, the diffuse angle and the number of daughter channels. Results show that the...