Ferrofluidic open loop pulsating heat pipes: Efficient candidates for thermal management of electronics

Mohammadi, M ; Sharif University of Technology

996 Viewed
  1. Type of Document: Article
  2. DOI: 10.1080/08916152.2013.782377
  3. Abstract:
  4. Thermal management of electronic devices is presently a serious concern. This article investigates the thermal performance of a five-turn open-loop pulsating heat pipe in both start-up and steady thermal conditions. The effects of working fluid, namely water and ferrofluid, heat input, charging ratio, ferrofluid concentration, orientation, as well as application of magnetic field, are explored. Experimental results show that using ferrofluid enhances the thermal performance in comparison with the case of distilled water under certain conditions. In addition, applying a magnetic field on the open-loop pulsating heat pipe charged with ferrofluid improves its thermal performance. Charging ratios that lead to lower thermal are mentioned. Optimum concentration of ferrofluid in steady-state performance is 2.5 g/L. This study helps to design electronic cooling devices more efficiently
  5. Keywords:
  6. Charging ratio ; Concentration ; Open-loop pulsating heat pipe ; Thermal management ; Charging ratios ; Ferrofluid ; Loop pulsating heat pipes ; Optimum concentration ; Pulsating heat pipe ; Steady state performance ; Thermal condition ; Thermal Performance ; Concentration (process) ; Heat pipes ; Magnetic fields ; Temperature control
  7. Source: Experimental Heat Transfer ; Vol. 27, issue. 3 , Dec , 2014 , p. 296-312 ; ISSN: 08916152
  8. URL: http://www.tandfonline.com/doi/abs/10.1080/08916152.2013.782377?journalCode=ueht20#.VeU0QH25JIE