Loading...
Search for: testing-systems
0.01 seconds
Total 100 records

    Modified artificial bee colony algorithm based on fuzzy multi-objective technique for optimal power flow problem

    , Article Electric Power Systems Research ; Volume 95 , 2013 , Pages 206-213 ; 03787796 (ISSN) Khorsandi, A ; Hosseinian, S. H ; Ghazanfari, A ; Sharif University of Technology
    2013
    Abstract
    This paper presents a fuzzy based modified artificial bee colony (MABC) algorithm to solve discrete optimal power flow (OPF) problem that has both discrete and continuous variables considering valve point effects. The OPF problem is formulated as a multi-objective mixed-integer nonlinear problem, where optimal settings of the OPF control variables for simultaneous minimization of total fuel cost of thermal units, total emission, total real power losses, and voltage deviation are obtained. The proposed approach is applied to the OPF problem on IEEE 30-bus and IEEE 118-bus test systems. The performance and operation of the proposed approach is compared with the conventional methods. The... 

    Transmission grid fault diagnosis by wide area measurement system

    , Article IEEE PES Innovative Smart Grid Technologies Conference Europe ; 2012 ; 9781467325974 (ISBN) Salehi Dobakhshari, A ; Ranjbar, A. M ; Sharif University of Technology
    2012
    Abstract
    While the importance of wide area measurement system (WAMS) consisting of phasor measurement units (PMUs) is recognized, there are still unidentified applications that can be addressed with the advance of technology. Traditionally, power system operators diagnosed the fault point through the status of protective relays and circuit breakers of the protection system. In large blackouts, however, the malfunction of protection system has itself often been among the suspects of the disaster. This paper proposes an alternative fault diagnosis approach independent of the function of protection system, utilizing PMU data and bus impedance matrix (Zbus). First, the proposed method diagnoses the fault... 

    A decision tree-based method for power system fault diagnosis by synchronized Phasor Measurements

    , Article IEEE PES Innovative Smart Grid Technologies Conference Europe ; 2012 ; 9781467325974 (ISBN) Dehkordi, P. Z ; Dobakhshari, A. S ; Ranjbar, A. M ; Sharif University of Technology
    2012
    Abstract
    This paper introduces a novel approach for power system fault diagnosis based on synchronized phasor measurements during the fault. The synchronized measurements are obtained in real time from Phasor Measurement Units (PMUs) and compared with offline thresholds determined by decision trees (DTs) to diagnose the fault. The DTs have already been trained offline using detailed power system analysis for different fault cases. While the traditional methods for fault diagnosis use the status of protective relays (PRs) and circuit breakers (CBs) to infer the fault section in the power system, the proposed method uses the available signals following the fault and thus can be trusted even in case of... 

    Constructing the Bayesian network for components reliability importance ranking in composite power systems

    , Article International Journal of Electrical Power and Energy Systems ; Volume 43, Issue 1 , 2012 , Pages 474-480 ; 01420615 (ISSN) Daemi, T ; Ebrahimi, A ; Fotuhi Firuzabad, M ; Sharif University of Technology
    Abstract
    In this paper, Bayesian Network (BN) is used for reliability assessment of composite power systems with emphasis on the importance of system components. A simple approach is presented to construct the BN associated with a given power system. The approach is based on the capability of the BN to learn from data which makes it possible to be applied to large power systems. The required training data is provided by state sampling using the Monte Carlo simulation. The constructed BN is then used to perform different probabilistic assessments such as ranking the criticality and importance of system components from reliability perspective. The BN is also used to compute the frequency and... 

    Iteration PSO with time varying acceleration coefficients for solving non-convex economic dispatch problems

    , Article International Journal of Electrical Power and Energy Systems ; Volume 42, Issue 1 , November , 2012 , Pages 508-516 ; 01420615 (ISSN) Mohammadi Ivatloo, B ; Rabiee, A ; Soroudi, A ; Ehsan, M ; Sharif University of Technology
    2012
    Abstract
    This paper presents a novel heuristic algorithm for solving economic dispatch (ED) problems, by employing iteration particle swarm optimization with time varying acceleration coefficients (IPSO-TVAC) method. Due to the effect of valve-points and prohibited operation zones (POZs) in the generating units' cost functions, ED problem is a non-linear and non-convex optimization problem. The problem even may be more complicated if transmission losses are taken into account. The effectiveness of the proposed method is examined and validated by carrying out extensive tests on three different test systems. Valve-point effects, POZs, ramp-rate constraints and transmission losses are modeled. Numerical... 

    Simultanous emergency demand response programming and unit commitment programming in comparison with interruptible load contracts

    , Article IET Generation, Transmission and Distribution ; Volume 6, Issue 7 , 2012 , Pages 605-611 ; 17518687 (ISSN) Sahebi, M. M ; Duki, E. A ; Kia, M ; Soroudi, A ; Ehsan, M ; Sharif University of Technology
    2012
    Abstract
    Different reasons such as power system restructuring, electricity price variation in some hours of a day and growth in the fuel price, have led to more attention to demand response (DR) programmes for consumers. Two important issues in DR programmes are emergency demand response programming (EDRP) and Interruptible/Curtail able (I/C) programme that is utilised as interruptible load contracts (ILC). The EDDR is utilised to decrease the consumption in peak load or critical hours of the day. This occurs by means of customer's behaviour in response to the incentives. However, the curtailment of voluntarily loads in the critical hours considering the consumer requirements is an action that can be... 

    Optimal reactive power dispatch for improving voltage stability margin using a local voltage stability index

    , Article Energy Conversion and Management ; Volume 59 , 2012 , Pages 66-73 ; 01968904 (ISSN) Rabiee, A ; Vanouni, M ; Parniani, M ; Sharif University of Technology
    2012
    Abstract
    Management of reactive power resources is vital for stable and secure operation of power systems in the view point of voltage stability. This paper deals with the management of on-load tap changers (OLTCs) and dynamic VAR sources (including synchronous generators, synchronous condensers, and shunt reactive power compensators) to improve voltage stability margin (VSM) of power systems. This problem is usually called optimal reactive power dispatch (ORD) in the literature. The main contribution of the paper is to introduce a new objective function for the ORD problem. The proposed objective function is derived based on a local voltage stability index, called DSY, and has a strong correlation... 

    Voltage stability improvement through centralized reactive power management on the Smart Grid

    , Article 2012 IEEE PES Innovative Smart Grid Technologies, ISGT 2012, 16 January 2012 through 20 January 2012 ; 2012 ; 9781457721588 (ISBN) Kazari, H ; Abbaspour-Tehrani Fard, A ; Dobakhshari, A. S ; Ranjbar, A. M ; Sharif University of Technology
    2012
    Abstract
    With the increasing penetration of renewable energies as distributed generation (DG) in power systems, technical problems arise in both distribution and transmission system level. Voltage rise is the main barrier for connection of DGs in rural areas, while excessive reactive power demand from transmission system is the major concern for Transmission System Operators (TSO). Here, a centralized control scheme based on the Smart Grid is proposed to reduce the impact on the transmission system voltages and improve its stability, while mitigating the voltage rise issue in the distribution network. Reactive power output of DGs, substation capacitors and tap setting of transmission transformer are... 

    Time-varying acceleration coefficients IPSO for solving dynamic economic dispatch with non-smooth cost function

    , Article Energy Conversion and Management ; Volume 56 , 2012 , Pages 175-183 ; 01968904 (ISSN) Mohammadi Ivatloo, B ; Rabiee, A ; Ehsan, M ; Sharif University of Technology
    2012
    Abstract
    The objective of the dynamic economic dispatch (DED) problem is to schedule power generation for the online units for a given time horizon economically, satisfying various operational constraints. Due to the effect of valve-point effects and prohibited operating zones (POZs) in the generating units cost functions, DED problem is a highly non-linear and non-convex optimization problem. The DED problem even may be more complicated if transmission losses and ramp-rate constraints are taken into account. This paper presents a novel and heuristic algorithm to solve DED problem of generating units, by employing time varying acceleration coefficients iteration particle swarm optimization... 

    Optimal PMU placement by an equivalent linear formulation for exhaustive search

    , Article IEEE Transactions on Smart Grid ; Volume 3, Issue 1 , 2012 , Pages 174-182 ; 19493053 (ISSN) Azizi, S ; Dobakhshari, A. S ; Nezam Sarmadi, S. A ; Ranjbar, A. M ; Sharif University of Technology
    Abstract
    Observability of bulk power transmission network by means of minimum number of phasor measurement units (PMUs), with the aid of the network topology, is a great challenge. This paper presents a novel equivalent integer linear programming method (EILPM) for the exhaustive search-based PMU placement. The state estimation implemented based on such a placement is completely linear, thereby eliminating drawbacks of the conventional SCADA-based state estimation. Additional constraints for observability preservation following single PMU or line outages can easily be implemented in the proposed EILPM. Furthermore, the limitation of communication channels is dealt with by translation of nonlinear... 

    Optimized midterm preventive maintenance outage scheduling of thermal generating units

    , Article IEEE Transactions on Power Systems ; Volume 27, Issue 3 , 2012 , Pages 1354-1365 ; 08858950 (ISSN) Abiri Jahromi, A ; Fotuhi Firuzabad, M ; Parvania, M ; Sharif University of Technology
    2012
    Abstract
    This paper addresses the midterm preventive maintenance outage scheduling problem of thermal generating units which is becoming increasingly important due to the aging of power generation fleet. In this context, a novel midterm preventive maintenance outage scheduler is proposed based on decision tree and mixed integer linear formation which explicitly considers the thermal units aging momentum in terms of failure rate. This allows the system operators to determine the thermal units' maintenance outage window based on the cost/benefit analysis of preventive maintenance tasks while optimizing the time interval between consecutive maintenance tasks. Additionally, the division of the year-long... 

    Optimized sectionalizing switch placement strategy in distribution systems

    , Article IEEE Transactions on Power Delivery ; Volume 27, Issue 1 , 2012 , Pages 362-370 ; 08858977 (ISSN) Abiri Jahromi, A ; Fotuhi Firuzabad, M ; Parvania, M ; Mosleh, M ; Sharif University of Technology
    2012
    Abstract
    Automation is acknowledged by distribution utilities as a successful investment strategy to enhance reliability and operation efficiency. However, practical approaches that can handle the complex decision-making process faced by decision makers to justify the long-term financial effects of distribution automation have remained scarce. An automated and remote-controlled sectionalizing switch play a fundamental role in an automated distribution network. This paper introduces a new optimization approach for distribution automation in terms of automated and remotely controlled sectionalizing switch placement. Mixed-integer linear programming (MILP) is utilized to model the problem. The proposed... 

    Role of fiber arrangements in operation of a double-fiber opto-mechanical system

    , Article Journal of Applied Sciences ; Volume 11, Issue 16 , 2011 , Pages 3001-3007 ; 18125654 (ISSN) Entezari, E ; Golnabi, H ; Sharif University of Technology
    2011
    Abstract
    Determination of the surface structure using the light reflection is an important issue. The aim is to study such surface reflections using an opto-mechanical system. The effects of the fiber arrangements in the operation of an opto-pair probe system for surface profiling are described. The opto-mechanical testing system consists of a double-fiber optical probe design and an electro-mechanical scanning system. Reflection signals for the plane and cylindrical surfaces made with different curvatures and materials are investigated with both probes and the results are compared. The reflection signal for the plane surface is independent of the double-fiber orientation in probe but for the curves... 

    Possibilistic evaluation of distributed generations impacts on distribution networks

    , Article IEEE Transactions on Power Systems ; Volume 26, Issue 4 , 2011 , Pages 2293-2301 ; 08858950 (ISSN) Soroudi, A ; Ehsan, M ; Caire, R ; Hadjsaid, N ; Sharif University of Technology
    Abstract
    In deregulated power systems, the distribution network operator (DNO) is not responsible for investment in distributed generation (DG) units, and they are just concerned about the best architecture ensuring a good service quality to their customers. The investment and operating decisions related to DG units are then taken by entities other than DNO which are exposed to uncertainty. The DNO should be able to evaluate the technical effects of these uncertain decisions. This paper proposes a fuzzy evaluation tool for analyzing the effect of investment and operation of DG units on active losses and the ability of distribution network in load supply at presence of uncertainties. The considered... 

    Impacts of service quality regulation on distribution automation investment

    , Article 2011 10th International Conference on Environment and Electrical Engineering, EEEIC.EU 2011 - Conference Proceedings, 8 May 2011 through 11 May 2011 ; May , 2011 , Page(s): 1 - 4 ; 9781424487820 (ISBN) Modarresi, M. S ; Fotuhi Firuzabad, M ; Mohammadnezhad Shourkaei, H ; Sharif University of Technology
    2011
    Abstract
    This paper investigates the effects of service quality regulation on investing in distribution automation. Among different regulatory instruments for quality regulation, the Reward-Penalty Scheme (RPS) has been selected to evaluate the effect of monetary incentive on behavior of Electric Distribution Utility (EDU) for service reliability. By implementing different automation strategies, the value of enhancing reliability indices and consequently the value of rewards and penalties are calculated for each strategy. For achieving to more realistic outcome, ten years horizon is considered. Furthermore, in the calculation of reliability indices, the time varying failure rate of components is... 

    Interval type-2 fuzzy modeling of wind power generation in Genco's generation scheduling

    , Article Electric Power Systems Research ; Volume 81, Issue 8 , 2011 , Pages 1696-1708 ; 03787796 (ISSN) Siahkali, H ; Vakilian, M ; Sharif University of Technology
    Abstract
    Wind power is a promising source of electric power generation since it has tremendous environmental and social benefits. The generation scheduling (GS) problem encounters several uncertainties in terms of the system's parameters such as load, reserve and available wind power generation. The modeling of those uncertainties is an important issue in power system scheduling. A fuzzy based modeling approach can be used to develop the generation schedule under an uncertain environment. In this paper, the type-2 fuzzy membership function (MF) is implemented to model the linguistic uncertainty of type-1 MF of available wind power generation which stems from opinions of different experts. The... 

    Combined model of mass-transfer coefficients for clean and contaminated liquid-liquid systems

    , Article Industrial and Engineering Chemistry Research ; Volume 50, Issue 8 , 2011 , Pages 4608-4617 ; 08885885 (ISSN) Haghdoost, A ; Dehkordi, A. M ; Darbandi, M ; Shahalami, M ; Saien, J ; Sharif University of Technology
    Abstract
    Mass-transfer rates to and from drops in liquid-liquid extraction processes are often reduced by the presence of contaminants. To design an industrial extractor, it is essential to consider this contamination effect in a quantitative manner. To achieve this goal, an experimental investigation was conducted on the mass transfer into single drops for n-butanol-succinic acid-water, as the recommended test system by the European Federation of Chemical Engineering (EFCE). The effects of anionic (sodium dodecyl sulfate, SDS), cationic (dodecyl trimethyl ammonium chloride, DTMAC), and nonionic (octylphenol decaethylene glycol ether, Triton X-100) surfactants on the hydrodynamic and mass-transfer... 

    Distribution system planning considering integration of distributed generation and load curtailment options in a competitive electricity market

    , Article Electrical Engineering ; Volume 93, Issue 1 , 2011 , Pages 23-32 ; 09487921 (ISSN) Porkar, S ; Abbaspour Tehrani Fard, A ; Poure, P ; Saadate, S ; Sharif University of Technology
    Abstract
    Distribution systems management is becoming an increasingly complicated issue due to the introduction of new technologies, new energy trading strategies and new deregulated environment. In the new deregulated energy market and considering the incentives coming from the technical and economical fields, it is reasonable to consider distributed generation (DG) as a viable option to solve the lacking electric power supply problem. This paper presents a mathematical distribution system planning model considering three planning options to system expansion and to meet the load growth requirements with a reasonable price as well as the system power quality problems. DG is introduced as an attractive... 

    Optimal placement of PMUs to maintain network observability using a modified BPSO algorithm

    , Article International Journal of Electrical Power and Energy Systems ; Volume 33, Issue 1 , January , 2011 , Pages 28-34 ; 01420615 (ISSN) Hajian, M ; Ranjbar, A. M ; Amraee, T ; Mozafari, B ; Sharif University of Technology
    2011
    Abstract
    This paper presents a novel approach to optimal placement of Phasor Measurement Units (PMUs) for state estimation. At first, an optimal measurement set is determined to achieve full network observability during normal conditions, i.e. no PMU failure or transmission line outage. Then, in order to consider contingency conditions, the derived scheme in normal conditions is modified to maintain network observability after any PMU loss or a single transmission line outage. Observability analysis is carried out using topological observability rules. A new rule is added that can decrease the number of required PMUs for complete system observability. A modified Binary Particle Swarm Optimization... 

    Identifying critical components for reliability centred maintenance management of deregulated power systems

    , Article IET Generation, Transmission and Distribution ; Volume 9, Issue 9 , 2015 , Pages 828-837 ; 17518687 (ISSN) Ghorani, R ; Fotuhi Firuzabad, M ; Dehghanian, P ; Li, W ; Sharif University of Technology
    Abstract
    Competition in the electric power industry urges utilities to not only reduce the investment costs, but also to reasonably cut the operation and maintenance expenses as much as possible, while keeping both power quality and reliability requirements met. Reliability-centred maintenance (RCM) has been proven to be in response to this dilemma in power systems and has been yet successfully applied in various engineering contexts. This study introduces a novel approach, as of the first steps of RCM implementation in composite power generation and transmission systems, to identify the critical components for the main sake of a more focused maintenance management. Criticality evaluation is, here,...