    Optimal distributed generation allocation in distribution network using Hereford Ranch algorithm

    , Article ICEMS 2005: 8th International Conference on Electrical Machines and Systems, Nanjing, 27 September 2005 through 29 September 2005 ; Volume 2 , 2005 , Pages 916-918 ; 7506274078 (ISBN); 9787506274074 (ISBN) Gandomkar, M ; Vakilian, M ; Ehsan, M ; Sharif University of Technology
    IEEE Computer Society  2005
    Abstract
    The necessity for flexible electric systems, energy saving, loss reducing and environmental impact are providing Impetus to the development of Distributed Generation (DG). DG Includes the application of small generators, scattered throughout a power system, to provide the electric power needed by electrical customer. Such locally distributed generation, has several merits from the viewpoint of environmental restriction and location limitations, as well as transient and voltage stability In the power system. The exact solution of the DG allocation can be obtained by a complete enumeration of all feasible combinations of sites and sizes of DGs In the network. The number of alternatives could... 

    Generation expansion planning of stand-alone micro-power systems using MADM techniques

    , Article 42nd International Universities Power Engineering Conference, UPEC 2007, Brighton, 4 September 2007 through 6 September 2007 ; 2007 , Pages 68-72 ; 1905593368 (ISBN); 9781905593361 (ISBN) Khodayar, M. E ; Afsharnia, S ; Ehsan, M ; Kamalinia, S ; Sedighizadeh, M ; Sharif University of Technology
    2007
    Abstract
    In this paper, Analytic Hierarchy Process and Data Envelopment Analysis are introduced as multi attribute decision making techniques in planning of standalone micro-power systems. The objective of the planning framework is to select the best configuration and capacity of different generating technologies in micro-power systems to minimize certain economical and environmental attributes. The economical attributes are capital cost and net present cost and the environmental attribute is emission. The proposed framework is illustrated by a case study on a real network in northern region of Iran  

    Investigating the effects of reactive power on islanding detection

    , Article 2004 International Conference on Power System Technology, POWERCON 2004, 21 November 2004 through 24 November 2004 ; Volume 2 , 2004 , Pages 1067-1071 ; 0780386108 (ISBN) Rajabi Ghahnavie, A ; Parniani, M ; Fotuhi Firuzabad, M ; Sharif University of Technology
    2004
    Abstract
    Distributed generation (DG) portion of power production is increasing more and more. DG poses different benefits and difficulties in a power system. Inadvertent islanding is a problem with DG which may cause health danger to line crew and can damage both DG and power system equipments. This paper investigates the effect of reactive power on ROCOF islanding detection method. Impacts of load power factor and load combination are studied using a sample test system. The paper offers a corrective method to cope with impacts of load reactive power. A way is suggested to locate DG such that the role of reactive power becomes a positive factor in islanding detection. © 2004 IEEE  

    Impact of distributed generation resources on customer interruption cost

    , Article 2004 International Conference on Power System Technology, POWERCON 2004, 21 November 2004 through 24 November 2004 ; Volume 1 , 2004 , Pages 856-861 ; 0780386108 (ISBN) Rajabi Ghahnavie, A ; Fotuhi Firuzabad, M ; Parniani, M ; Sharif University of Technology
    2004
    Abstract
    The electric power industry around the world is presently undergoing considerable changes with respect to structure, operation and regulation. Distributed generation is expected to play a major role in this new environment One the main benefits of DG is to enhance system reliability as it can restore power to the separated or bottle-necked part of distribution system in case of a contingency occurs. This paper presents an approach to examine and evaluates the applicability and customer interruption cost analysis in DG-connected distribution system in a specified planning horizon. The impacts on customer interruption cost reduction of different load growth rate, DG location and different... 

    Voltnar control in distribution networks with distributed generation

    , Article 5th IFAC Symposium on Power Plants and Power Systems Control 2003, 15 September 2003 through 19 September 2003 ; Volume 36, Issue 20 , 2003 , Pages 547-552 ; 14746670 (ISSN) Niknam, T ; Ranjbar, A. M ; Shirane, A. R ; Sharif University of Technology
    IFAC Secretariat  2003
    Abstract
    Due to the deregulation and restructuring in many countries, it is expected that amount of small-scale generations connected to the distribution networks increase. So it is necessary that impact of these kinds ofgenerators on VoltNar control would be investigated. This paper presents a new approach for VoltNar control in distribution system with Distributed Generation (DG) and it has shown that DG can improve the entire performance of network, by means of better controlling of the system and decreasing losses in network. In this approach Genetic Algorithm (GA) has been used as the optimization method where the amount of Dispersed Generation and its controlling parameters, Voltage regulators... 

    Design of a Coupled Thermoacoustic Refrigerator System based on Heat Absorption of Piston Engines of Power Plants

    , M.Sc. Thesis Sharif University of Technology Dehghani, Ali (Author) ; Mazaheri, Karim (Supervisor)
    Abstract
    Design and parametric study of a coupled thermoacoustic refrigerator system has been carried out based on thermoacoustic theories. The purpose of coupled thermoacoustic refrigerator design is to cool a container with small dimensions for use in cold storage above zero. The application of this refrigerator is where the waste heat of piston engines of distributed generation (DG) plants can be used as energy input. The design is based on the simplicity and low cost of the refrigerator. Therefore, the engine and refrigerator part of the coupled thermoacoustic refrigerator is enclosed in a resonator with a fixed diameter, which is closed on both sides of the resonator. Two standing-wave... 

    The Assessment of Cyber_Attacks on Electric Vehicles Charging by a Microgrid (Bus and Personal Vehicle)and Examining the Relevant Consequences in the Power Distribution Grid

    , M.Sc. Thesis Sharif University of Technology Akbarian, Amir Hossein (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    Todays, thanks to the positive effects of electric vehicles, (against the vehicles which use patrol as their fuel), reduction of the Earth temperature and its climate change; the manufacturing, sale and use of electric vehicles experience a sharp increase. In addition to decreasing the air pollution, due to their abundant smart implications, they have been dramatically propagated. Massive use of these devices has raised the concern about the loss of the security which is indispensable part of the infrastructure. None of the past publications and works have taken the cyber-attack on the charging price rate and other data into account. In this thesis, charging methods of electric vehicles are... 

    Centralized optimal management of a smart distribution system considering the importance of load reduction based on prioritizing smart home appliances

    , Article IET Generation, Transmission and Distribution ; Volume 16, Issue 19 , 2022 , Pages 3874-3893 ; 17518687 (ISSN) Sanaei, S ; Haghifam, M. R ; Safdarian, A ; Sharif University of Technology
    John Wiley and Sons Inc  2022
    Abstract
    The distribution system's economic operation is significantly impacted by the management of distributed generation (DG) resources, energy storage (ES), and controllable loads. The paper employs a smart distribution system that incorporates dispatchable and non-dispatchable DG resources, as well as battery storage, in addition to the demand response (DR) scheme. New modelling was performed in hourly steps to achieve the optimal unit commitment. In smart homes, appliances are prioritized and classified into four types: adjustable, interruptible, shiftable, and uncontrollable loads. Load reduction in smart homes is also considered based on load prioritization and customer participation in the... 

    IoT-based intelligent source–load–storage coordination scheme for prosumer campus microgrids

    , Article Frontiers in Energy Research ; Volume 10 , 2022 ; 2296598X (ISSN) Abdul Muqeet, H ; Shahzad, M ; Shehzad, M ; Akhter, J ; Almohaimeed, Z. M ; Akram, R ; Hussain, M. M ; Sharif University of Technology
    Frontiers Media S.A  2022
    Abstract
    Electrical energy is very necessary for human life in the modern era. The rising energy prices, depletion of fossil fuels, and instability of the grid are alarming situations. So, it needs a smart solution to ensure the balance between pricing and saving natural resources. Some other issues like environmental change, limitations on installation of new transmission lines, reliability concerns, and considering the expansion in distributed energy generation technologies promise the implementation of distributed generation extensively. The integration of two or more energy supplies in a power system is known as distributed energy resource system. In this study, a university campus is taken as a... 

    On the explicit formulation of reliability assessment of distribution systems with unknown network topology: Incorporation of DG, switching interruptions, and customer-interruption quantification

    , Article Applied Energy ; Volume 324 , 2022 ; 03062619 (ISSN) Jooshaki, M ; Lehtonen, M ; Fotuhi Firuzabad, M ; Muñoz Delgado, G ; Contreras, J ; Arroyo, J. M ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    This paper presents an original approach for the evaluation of reliability of active distribution networks with unknown topology. Built upon novel reformulations of conventional definitions for distribution reliability indices, the dependence of system-oriented reliability metrics on network topology is explicitly formulated using a set of mixed-integer linear expressions. Unlike previously reported works also modeling mathematically the relationship between reliability assessment and network topology, the proposed approach allows considering the impact of distributed generation (DG) while accounting for switching interruptions. Moreover, for the first time in the emerging closely related... 

    Scheduling and sizing of campus microgrid considering demand response and economic analysis

    , Article Sensors ; Volume 22, Issue 16 , 2022 ; 14248220 (ISSN) Bin, L ; Shahzad, M ; Javed, H ; Muqeet, H. A ; Akhter, M. N ; Liaqat, R ; Hussain, M. M ; Sharif University of Technology
    MDPI  2022
    Abstract
    Current energy systems face multiple problems related to inflation in energy prices, reduction of fossil fuels, and greenhouse gas emissions which are disturbing the comfort zone of energy consumers and the affordability of power for large commercial customers. These kinds of problems can be alleviated with the help of optimal planning of demand response policies and with distributed generators in the distribution system. The objective of this article is to give a strategic proposition of an energy management system for a campus microgrid (µG) to minimize the operating costs and to increase the self-consuming energy of the green distributed generators (DGs). To this end, a real-time based... 

    Sustainable solutions for advanced energy management system of campus microgrids: model opportunities and future challenges

    , Article Sensors ; Volume 22, Issue 6 , 2022 ; 14248220 (ISSN) Muqeet, H. A ; Javed, H ; Akhter, M. N ; Shahzad, M ; Munir, H. M ; Nadeem, M. U ; Bukhari, S. S. H ; Huba, M ; Sharif University of Technology
    MDPI  2022
    Abstract
    Distributed generation connected with AC, DC, or hybrid loads and energy storage systems is known as a microgrid. Campus microgrids are an important load type. A university campus microgrids, usually, contains distributed generation resources, energy storage, and electric vehicles. The main aim of the microgrid is to provide sustainable, economical energy, and a reliable system. The advanced energy management system (AEMS) provides a smooth energy flow to the microgrid. Over the last few years, many studies were carried out to review various aspects such as energy sustainability, demand response strategies, control systems, energy management systems with different types of optimization... 

    A multi-objective framework for distributed energy resources planning and storage management

    , Article Applied Energy ; Volume 314 , 2022 ; 03062619 (ISSN) Ahmadi, B ; Ceylan, O ; Ozdemir, A ; Fotuhi Firuzabad, M ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    The use of energy storage systems (ESS) and distributed generators (DGs) to improve reliability is one of the solutions that has received much attention from researchers today. In this study, we utilize a multi-objective optimization method for optimal planning of distributed generators in electric distribution networks from the perspective of multi-objective optimization. The objective is to improve the reliability of the network while reducing the annual cost and network losses. A modified version of the multi-objective sine–cosine algorithm is used to determine the optimal size, location, and type of DGs and the optimal capacity, location, and operation strategy of the ESS. Three case... 

    Energy management of Plug-In Hybrid Electric Vehicles in renewable-based energy hubs

    , Article Sustainable Energy, Grids and Networks ; Volume 32 , 2022 ; 23524677 (ISSN) Moeini Aghtaie, M ; Dehghanian, P ; Davoudi, M ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Proliferation of Plug-in Hybrid Electric Vehicles (PHEVs) and integration of various distributed generation (DG) technologies have been recognized to play an undeniable role in modern power systems of the future. In order to effectively model the interactions of these two technologies, this paper develops a multi-criteria framework to coordinate the charging behaviors of PHEVs within an energy hub platform. In this regard, the desirable charging profiles from the viewpoint of both PHEV owners and hub manager are first captured and reported to the PHEVs Coordinator Entity (PCE). The PCE, then, runs an optimization framework in which several criteria including the PHEV owners’ convenience,... 

    An Milp model for switch, DG, and tie line placement to improve distribution grid reliability

    , Article IEEE Systems Journal ; 2022 , Pages 1-12 ; 19328184 (ISSN) Zare Bahramabadi, M ; Ehsan, M ; Farzin, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2022
    Abstract
    Remote controlled switches (RCSs) have the ability to isolate the faulted area from other parts of the distribution system. On the other hand, the dispatchable distributed generators (DDGs) and tie lines can supply the interrupted loads after fault occurrence trough microgrids and reduce the outage time. In this regard, this article proposes a planning model for simultaneous placement of RCSs, DDGs, and tie lines to improve distribution system reliability. The presence of renewable distributed generations (RDGs) and energy storage systems, which have an increasing penetration in today's distribution networks are also considered. Moreover, two different practical load shedding methods are... 

    Probabilistic analysis to analyze uncertainty incorporating copula theory

    , Article Journal of Electrical Engineering and Technology ; Volume 17, Issue 1 , 2022 , Pages 61-71 ; 19750102 (ISSN) Li, B ; Shahzad, M ; Munir, H. M ; Nawaz, A ; Fahal, N. A. M ; Khan, M. Y. A ; Ahmed, S ; Sharif University of Technology
    Korean Institute of Electrical Engineers  2022
    Abstract
    The emerging trend of distribution generation with existing power system network leads uncertainty factor. To handle this uncertainty, it is a provocation for the power system control, planning, and operation engineers. Although there are numerous techniques to model and evaluate these uncertainties, but in this paper the integration of Copula theory with Improved Latin-hypercube Sampling (ILHS) are incorporated for Probabilistic load Flow (PLF) evaluation. In probabilistic research approaches, the dominant interest is to achieve appropriate modelling of input random variables and reduce the computational burden. To address the said problem, Copula theory is applied to execute the modelling...